To operate dual-active-bridge isolated bidirectional dc– dc converter (DAB) at high efficiency, the two bridge switches must operate with Zero-Voltage-Switching (ZVS) over as wide an operating range as possible. This paper proposes a new perspective on realizing ZVS in dead-time. An exact theoretical analysis and mathematical mode is built to explain the process of ZVS switching in dead-time under Single Phase Shift (SPS) control strategy. In order to assure the two bridge switches operate on soft switching, every SPS switching point is analyzed. Generally, dead-time will be determined when the power electronic devices is selected. The key factor to realizing ZVS is the size of the end time of resonance comparing to dead-time. Through detailed analysis, it can obtain the conditions of all switches achieving ZVS turn-on and turn-off. Finally, simulation validates the theoretical analysis and some advice are given to realize the ZVS soft switching.
24 September 2025 in IEEE Transactions on Instrumentation and Measurement
Insulation degradation is an important cause of inverter-fed motor failures. In order to improve the safety of electric motor systems and to avoid sudden failures, timely monitoring of motor insulation degradation is necessary. The high-frequency common-mode leakage current flowing through the groundwall insulation reflects the degradation of the groundwall insulation, especially that of the first few turns. In this paper, an insulation condition monitoring method based on leakage current is proposed. An improved common-mode model of the winding suitable for leakage current analysis is proposed, based on the characteristics of the common-mode impedance curve of the motor. By analyzing the mathematical relationship between high-frequency leakage current and insulation degradation in the first few turns, the insulation condition indicators are proposed, and it is validated by the experimental results. Based on this method, a suite of hardware for pre-processing leakage current waveforms is designed, thus providing a cost-effective insulation monitoring method that minimises both hardware and software requirements.
The reliability of traction-motor winding insulation directly affects the safe operation of electric vehicles. This study proposes a remaining useful life (RUL) prediction method for traction-motor main insulation using bipolar-pulse response measurements and Gaussian process regression (GPR). Simulated winding modules were subjected to full-lifecycle accelerated thermal aging at 300 °C. During the diagnostic stage of each aging subcycle, synchronized insulation-voltage and insulation-current waveforms were acquired at 50 MSPS. A 2 μs segment following the positive-polarity rising edge was processed using a Hann window, a 10th-order Butterworth band-pass filter from 2 to 12 MHz, and a 100-point fast Fourier transform. The frequency bin with the maximum current-spectrum magnitude was identified, and a frequency-weighted impedance feature was obtained from the voltage-to-current spectral-magnitude ratio at the same frequency. One complete lifetime trajectory containing 119 diagnostic measurements was evaluated retrospectively. The experimentally observed EOL at 428.405 h was independently established when the 10 kHz winding-to-ground capacitance fell to 44.6% of its initial value. A trend-informed GPR model was updated after each new measurement, and RUL was calculated from the first forecast crossing of the fixed feature threshold. Across ten rolling origins after 80% of the observed lifetime, the mean bounded relative accuracy was 80.08%, with an MAE of 6.455 h and an RMSE of 8.923 h. However, at the final origin, where the actual RUL was 4.185 h, the bounded relative accuracy was 0% because the terminal feature increase occurred abruptly between two measurements. The results constitute a single-specimen retrospective proof of concept; independent multi-specimen validation is required before predictive performance can be generalized.
The reliability of traction-motor winding insulation directly affects the safe operation of electric vehicles. This study proposes a remaining-useful-life (RUL) prediction method for traction-motor main insulation using bipolar-pulse response measurements and Gaussian process regression (GPR). Simulated winding modules were subjected to full-lifecycle accelerated thermal aging at 300 °C. During the diagnostic stage of each aging subcycle, bipolar high-voltage pulses were applied, and synchronized insulation-voltage and insulation-current waveforms were acquired at 50 MSPS. A 2 μs oscillatory segment associated with the positive-polarity rising edge was processed using a Hann window, a 10th-order Butterworth band-pass filter from 2 to 12 MHz, and a 100-point fast Fourier transform. The frequency bin with the maximum current-spectrum magnitude was identified, and the impedance magnitude was calculated from the voltage-to-current spectral-magnitude ratio at the same frequency. The impedance magnitude was then multiplied by the corresponding frequency to obtain a frequency-weighted impedance feature. The feature was corrected to a reference temperature of 85 °C. One complete lifetime trajectory containing 119 diagnostic measurements was used for proof-of-concept evaluation. The initial feature was 13.7076 Ω·MHz, and the end-of-life threshold was defined as twice this value, 27.4152 Ω·MHz. The first threshold crossing occurred at 428.405 h. A trend-informed GPR model combining causal averaging, monotonic trend extraction, a quadratic mean function, and a short-memory Matérn-3/2 residual process was updated after each new measurement. Across ten rolling prediction origins after 80% of the observed lifetime, all ten origins produced finite threshold-crossing-based RUL estimates. The mean bounded relative accuracy was 80.08%, with an MAE of 6.455 h and an RMSE of 8.923 h. The results demonstrate the feasibility of waveform-feature-based chronological RUL prediction, while independent multi-specimen validation remains necessary.