This work reports the development of arrays of infrared sensors (microbolometers) using a hydrogenated polymorphous silicon–germanium alloy (pm-SixGe1-x:H). Basically, polymorphous semiconductors consist of an amorphous semiconductor matrix with embedded nanocrystals of about 2–3 nm. The pm-SixGe1-x:H alloy studied has a high temperature coefficient of resistance (TCR) of 4.08%/K and conductivity of 1.5 × 10−5 S∙cm−1. Deposition of thermosensing film was made by plasma-enhanced chemical vapor deposition (PECVD) at 200 °C, while the area of the devices is 50 × 50 μm2 with a fill factor of 81%. Finally, an array of 19 × 20 microbolometers was packaged for electrical characterization. Voltage responsivity values were obtained in the range of 4 × 104 V/W and detectivity around 2 × 107 cm∙Hz1/2/W with a polarization current of 70 μA at a chopper frequency of 30 Hz. A minimum value of 2 × 10−10 W/Hz1/2 noise equivalent power was obtained at room temperature. In addition, it was found that all the tested devices responded to incident infrared radiation, proving that the structure and mechanical stability are excellent.
Aims. Some astronomical facilities are in operation at the Sierra Negra volcano (SNV), at ∼4.5 km over the sea level (o.s.l.) in Mexico. We asses whether it is possible to estimate the opacity for millimeter-wavelength observations based on the meteorological parameters at the site. A criterion for allowing astronomical observations at SNV depends on the atmospheric opacity at 225 GHz, which has to be τ225 ≤ 0.30 Nepers. The correlation of the opacity at SNV, measured with a radiometer at 225 GHz, τ225, with the local dew point temperature, TDP, the water vapor pressure, PH2O and the water vapor content (WVC) at SNV is studied with the aim to determine whether these parameters can be used to estimate the opacity at similar high-altitude locations for astronomical observations at millimeter wavelengths. Methods. We used radiosonde data taken in various decades in Mexico City (MX) and Veracruz City (VR) to compute the WVC in 0.5 km altitude (h) intervals from 0 km for VR and from 2.0 km for MX to 9.5 km o.s.l. to study the altitude profile WVC(h) at SNV by interpolating data of MX and VR. We also fit exponential functions to observed WVC (WVCobs(h)), obtaining a fit WVC (WVCftd(h)). The WVCobs(h) and WVCftd(h) were integrated, from lower limits of hlow = 2.5–5.5 km to the upper limit of 9.5 km as a measure of the input of WVCobs(h ≥ hlow) to the precipitable water vapor. Results. The largest differences between WVCobs and WVCftd values occur at low altitudes. The input of WVCobs(h) to the precitpitable water vapor for h ≥ 4.5 km ranges from 15% to 29%. At 4.5–5.0 km, the input is between 4% and 8%. This means that it is about a third of the WVC (h ≥ 4.5 km). The input above our limit (from 9.5–30.0 km) is estimated with WVCftd(h) and is found to be lower than 1%. The correlation of τ225 with TDP, PH2O, and WVCSNV takes values between 0.6 and 0.8. A functional relation is proposed based on simultaneous data taken in 2013–2015, according to which it is possible to estimate the opacity with the TDP, PH2O, or WVCSNV at the site. Conclusions. With local meteorological parameters, it is possible to know whether the opacity meets the condition τ225 ≤ 0.30 Nepers, with an uncertainty of ±0.16 Nepers. The uncertainty is low for low opacities and increases with increasing opacity.
This paper reports on the refurbishment of a dual-band 23/31 GHz tipping radiometer previously used to measure atmospheric water vapor content at the Hartebeesthoek Radio Astronomy Observatory. We describe the motivation for the refurbishment, provide technical details of the modifications made to the instrument, and present preliminary test results of field measurements at the site of the High Energy Stereoscopic System Observatory in Namibia. Together with other radiometric measurements, this instrument will contribute to the site characterization of potential radio astronomical observatories in southern Africa.
In this manuscript, we present an experimental setup capable to extract main electrical parameters and thermal effects from semiconductor devices within a range of temperatures from 300 K down to 350 mK. Key aspects of the system such as sample holder design and wire material selection, are discussed. One of the most critical design limitations is the maximum thermal power handling, since at sub-Kelvin temperatures the cooling power is limited by a 3 He 4 He fridge. The largest amount of heat transferred into the system comes from the electrical wiring, is reduced by the combined use of Copper and Manganin wires. This way we reach an optimized balance between electrical resistance and heat conduction. Therefore we ensure the DUT reaches the Ultra-Cold Stage (UCS) temperature while the electrical measurements are minimally affected by the electrical resistance. Under this condition the cryogenic system allows a reliable electrical characterization of a 14 nm SOI p-FinFET down to 350 mK.
The Large Millimeter Telescope (LMT) Alfonso Serrano is a bi-national (Mexico & USA) telescope facility operated by the Instituto Nacional de Astrofisica, Optica y Electronica (INAOE) and the University of Massachusetts. The LMT is designed as a 50-m diameter single-dish millimeter-wavelength telescope that is optimized to conduct scientific observations at frequencies between ~70 and 350 GHz. The LMT is constructed on the summit of Sierra Negra at an altitude of 4600m in the Mexican state of Puebla. The site offers excellent mm-wavelength atmospheric transparency all-year round, and the opportunity to conduct submillimeter wavelength observations during the winter months. Following first-light observations in mid-2011, the LMT began regular scientific operations in 2014 with a shared-risk Early Science observing program using the inner 32-m diameter of the primary reflector with an active surface control system. The LMT has already performed successful VLBI observations at 3mm with the High Sensitivity Array and also at 1.3mm as part of the Event Horizon Telescope. Since early 2018 the LMT has begun full scientific operations as a 50-m diameter telescope, making the LMT 50-m the world´s largest single-dish telescope operating at 1.1mm. I will describe the current status of the telescope project, including the early scientific results from the LMT 50-m, as well the instrumentation development program, the plan to improve the overall performance of the telescope, and the on-going transition towards the formation of the LMT Observatory to support the scientific community in their use of the LMT to study the formation and evolution of structure at all cosmic epochs.
14 April 2026 in Journal of Infrared, Millimeter, and Terahertz Waves
In this review article, a broad overview of multiple terahertz- and mm-wave-related activities in Latin America is presented. Latin America houses two of the largest radiotelescopes in the world, a synchrotron terahertz beam line, and multiple activities related to sources, detectors, and instrumentation are underway throughout the region. Furthermore, we describe applications of terahertz spectroscopy and imaging in materials inspection, biomedical, industrial, agronomical, and cultural heritage fields, among others. While we try to include a diverse collection of topics and research groups, this review is not exhaustive, and there are additional activities that we could not include.