Daniel Ferrusca

Dr. Daniel Ferrusca

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
RJRicardo Jimenez
Ricardo Jimenez
Mario MorenoMario Moreno
Mario Moreno
Alfonso TorresAlfonso Torres
Alfonso Torres
AMAlfredo Morales
Alfredo Morales
Arturo PonceArturo Ponce
Arturo Ponce
ECEduardo Cano
Eduardo Cano
This work reports the development of arrays of infrared sensors (microbolometers) using a hydrogenated polymorphous silicon–germanium alloy (pm-SixGe1-x:H). Basically, polymorphous semiconductors consist of an amorphous semiconductor matrix with embedded nanocrystals of about 2–3 nm. The pm-SixGe1-x:H alloy studied has a high temperature coefficient of resistance (TCR) of 4.08%/K and conductivity of 1.5 × 10−5 S∙cm−1. Deposition of thermosensing film was made by plasma-enhanced chemical vapor deposition (PECVD) at 200 °C, while the area of the devices is 50 × 50 μm2 with a fill factor of 81%. Finally, an array of 19 × 20 microbolometers was packaged for electrical characterization. Voltage responsivity values were obtained in the range of 4 × 104 V/W and detectivity around 2 × 107 cm∙Hz1/2/W with a polarization current of 70 μA at a chopper frequency of 30 Hz. A minimum value of 2 × 10−10 W/Hz1/2 noise equivalent power was obtained at room temperature. In addition, it was found that all the tested devices responded to incident infrared radiation, proving that the structure and mechanical stability are excellent.

28 April 2021 in Astronomy & Astrophysics
Verified
Journal Article
Closed access
PDF file
EMEduardo Mendoza-Torres
Eduardo Mendoza-Torres
ECEdgar Colín-Beltrán
Edgar Colín-Beltrán
DFDaniel Ferrusca
Daniel Ferrusca
RCR. J. Contreras
R. J. Contreras
Aims. Some astronomical facilities are in operation at the Sierra Negra volcano (SNV), at ∼4.5 km over the sea level (o.s.l.) in Mexico. We asses whether it is possible to estimate the opacity for millimeter-wavelength observations based on the meteorological parameters at the site. A criterion for allowing astronomical observations at SNV depends on the atmospheric opacity at 225 GHz, which has to be τ225 ≤ 0.30 Nepers. The correlation of the opacity at SNV, measured with a radiometer at 225 GHz, τ225, with the local dew point temperature, TDP, the water vapor pressure, PH2O and the water vapor content (WVC) at SNV is studied with the aim to determine whether these parameters can be used to estimate the opacity at similar high-altitude locations for astronomical observations at millimeter wavelengths. Methods. We used radiosonde data taken in various decades in Mexico City (MX) and Veracruz City (VR) to compute the WVC in 0.5 km altitude (h) intervals from 0 km for VR and from 2.0 km for MX to 9.5 km o.s.l. to study the altitude profile WVC(h) at SNV by interpolating data of MX and VR. We also fit exponential functions to observed WVC (WVCobs(h)), obtaining a fit WVC (WVCftd(h)). The WVCobs(h) and WVCftd(h) were integrated, from lower limits of hlow = 2.5–5.5 km to the upper limit of 9.5 km as a measure of the input of WVCobs(h ≥ hlow) to the precipitable water vapor. Results. The largest differences between WVCobs and WVCftd values occur at low altitudes. The input of WVCobs(h) to the precitpitable water vapor for h ≥ 4.5 km ranges from 15% to 29%. At 4.5–5.0 km, the input is between 4% and 8%. This means that it is about a third of the WVC (h ≥ 4.5 km). The input above our limit (from 9.5–30.0 km) is estimated with WVCftd(h) and is found to be lower than 1%. The correlation of τ225 with TDP, PH2O, and WVCSNV takes values between 0.6 and 0.8. A functional relation is proposed based on simultaneous data taken in 2013–2015, according to which it is possible to estimate the opacity with the TDP, PH2O, or WVCSNV at the site. Conclusions. With local meteorological parameters, it is possible to know whether the opacity meets the condition τ225 ≤ 0.30 Nepers, with an uncertainty of ±0.16 Nepers. The uncertainty is low for low opacities and increases with increasing opacity.

1 April 2025 in Review of Scientific Instruments
Verified
Journal Article
Open access
JCJ. Cuazoson
J. Cuazoson
DHDavid Hiriart
David Hiriart
TSTinus Stander
Tinus Stander
RBR. Botha
R. Botha
JCJ. Contreras
J. Contreras
MVMiguel Velázquez
Miguel Velázquez
This paper reports on the refurbishment of a dual-band 23/31 GHz tipping radiometer previously used to measure atmospheric water vapor content at the Hartebeesthoek Radio Astronomy Observatory. We describe the motivation for the refurbishment, provide technical details of the modifications made to the instrument, and present preliminary test results of field measurements at the site of the High Energy Stereoscopic System Observatory in Namibia. Together with other radiometric measurements, this instrument will contribute to the site characterization of potential radio astronomical observatories in southern Africa.

17 May 2021
Verified
Conference Paper
Closed access
MIMartínez-R. Ismael
Martínez-R. Ismael
OLOmar López-L
Omar López-L
DFDaniel Ferrusca
Daniel Ferrusca
MVMiguel Velázquez
Miguel Velázquez
EGEdmundo Gutierrez
Edmundo Gutierrez
FHF.J. De la Hidalga-W
F.J. De la Hidalga-W
In this manuscript, we present an experimental setup capable to extract main electrical parameters and thermal effects from semiconductor devices within a range of temperatures from 300 K down to 350 mK. Key aspects of the system such as sample holder design and wire material selection, are discussed. One of the most critical design limitations is the maximum thermal power handling, since at sub-Kelvin temperatures the cooling power is limited by a 3 He 4 He fridge. The largest amount of heat transferred into the system comes from the electrical wiring, is reduced by the combined use of Copper and Manganin wires. This way we reach an optimized balance between electrical resistance and heat conduction. Therefore we ensure the DUT reaches the Ultra-Cold Stage (UCS) temperature while the electrical measurements are minimally affected by the electrical resistance. Under this condition the cryogenic system allows a reliable electrical characterization of a 14 nm SOI p-FinFET down to 350 mK.

10 July 2018
Verified
Conference Paper
Closed access
DHDavid H. Hughes
David H. Hughes
FSF. Peter Schloerb
F. Peter Schloerb
MYMin S. Yun
Min S. Yun
MCMiguel Chávez
Miguel Chávez
GWGrant W. Wilson
Grant W. Wilson
AGArturo Gómez-Ruiz
Arturo Gómez-Ruiz
The Large Millimeter Telescope (LMT) Alfonso Serrano is a bi-national (Mexico & USA) telescope facility operated by the Instituto Nacional de Astrofisica, Optica y Electronica (INAOE) and the University of Massachusetts. The LMT is designed as a 50-m diameter single-dish millimeter-wavelength telescope that is optimized to conduct scientific observations at frequencies between ~70 and 350 GHz. The LMT is constructed on the summit of Sierra Negra at an altitude of 4600m in the Mexican state of Puebla. The site offers excellent mm-wavelength atmospheric transparency all-year round, and the opportunity to conduct submillimeter wavelength observations during the winter months. Following first-light observations in mid-2011, the LMT began regular scientific operations in 2014 with a shared-risk Early Science observing program using the inner 32-m diameter of the primary reflector with an active surface control system. The LMT has already performed successful VLBI observations at 3mm with the High Sensitivity Array and also at 1.3mm as part of the Event Horizon Telescope. Since early 2018 the LMT has begun full scientific operations as a 50-m diameter telescope, making the LMT 50-m the world´s largest single-dish telescope operating at 1.1mm. I will describe the current status of the telescope project, including the early scientific results from the LMT 50-m, as well the instrumentation development program, the plan to improve the overall performance of the telescope, and the on-going transition towards the formation of the LMT Observatory to support the scientific community in their use of the LMT to study the formation and evolution of structure at all cosmic epochs.

14 April 2026 in Journal of Infrared, Millimeter, and Terahertz Waves
Verified
Journal Article
Open access
PDF file
ECEnrique Castro-Camus
Enrique Castro-Camus
DFDaniel Ferrusca
Daniel Ferrusca
JCJohn Carpenter
John Carpenter
DHDavid Hughes
David Hughes
NQNaser Qureshi
Naser Qureshi
MOMonica Ortiz-Martinez
Monica Ortiz-Martinez
In this review article, a broad overview of multiple terahertz- and mm-wave-related activities in Latin America is presented. Latin America houses two of the largest radiotelescopes in the world, a synchrotron terahertz beam line, and multiple activities related to sources, detectors, and instrumentation are underway throughout the region. Furthermore, we describe applications of terahertz spectroscopy and imaging in materials inspection, biomedical, industrial, agronomical, and cultural heritage fields, among others. While we try to include a diverse collection of topics and research groups, this review is not exhaustive, and there are additional activities that we could not include.