Chengwei Luo

Mr. Chengwei Luo


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CLChengwei Luo
Chengwei Luo
DTDespina Tsementzi
Despina Tsementzi
NKNikos Kyrpides
Nikos Kyrpides
TRTimothy Read
Timothy Read
KKKonstantinos T. Konstantinidis
Konstantinos T. Konstantinidis
Next-generation sequencing (NGS) is commonly used in metagenomic studies of complex microbial communities but whether or not different NGS platforms recover the same diversity from a sample and their assembled sequences are of comparable quality remain unclear. We compared the two most frequently used platforms, the Roche 454 FLX Titanium and the Illumina Genome Analyzer (GA) II, on the same DNA sample obtained from a complex freshwater planktonic community. Despite the substantial differences in read length and sequencing protocols, the platforms provided a comparable view of the community sampled. For instance, derived assemblies overlapped in ∼90% of their total sequences and in situ abundances of genes and genotypes (estimated based on sequence coverage) correlated highly between the two platforms (R2>0.9). Evaluation of base-call error, frameshift frequency, and contig length suggested that Illumina offered equivalent, if not better, assemblies than Roche 454. The results from metagenomic samples were further validated against DNA samples of eighteen isolate genomes, which showed a range of genome sizes and G+C% content. We also provide quantitative estimates of the errors in gene and contig sequences assembled from datasets characterized by different levels of complexity and G+C% content. For instance, we noted that homopolymer-associated, single-base errors affected ∼1% of the protein sequences recovered in Illumina contigs of 10× coverage and 50% G+C; this frequency increased to ∼3% when non-homopolymer errors were also considered. Collectively, our results should serve as a useful practical guide for choosing proper sampling strategies and data possessing protocols for future metagenomic studies.

1 June 2020 in IEEE Access
Verified
Journal Article
Open access
CLChengwei Luo
Chengwei Luo
SHShoudao Huang
Shoudao Huang
This paper proposes a novel input voltage balancing control strategy for dual-active-bridge (DAB) input-series-output-parallel (ISOP) DC-DC converters. The proposed strategy not only aims at balancing the input voltage among modules but also at eliminating the coupling effect between input voltage sharing regulators (IVSR) and output voltage regulators (OVR). Specifically, this paper reveals it is too complicated to design a decoupling control structure that can eliminate the dynamic interference of IVSRs to OVRs by using traditional control strategies. Thus, an intermediate control variable, which was adjusted by the IVSR and OVR to simplify the decoupling control structure design, was introduced to calculate the phase-shift ratio. Furthermore, a new control law was derived, and an expression for the intermediate control variable modification was proposed to achieve decoupling control. Moreover, to complete the discussion, the main transfer functions were deduced and the design procedure was illustrated. Based on the novel control strategy, the interference of an IVSR to an OVR was eliminated, so the two controllers can be independently designed. Finally, both the simulation and experimental results were used to verify the performance of the novel control strategy.

8 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
FHFang Hu
Fang Hu
DLDerong Luo
Derong Luo
CLChengwei Luo
Chengwei Luo
ZLZhuo Long
Zhuo Long
ZRzhimeng Rao
zhimeng Rao
This paper presents a cascaded robust fault-tolerant predictive control (CRFTPC) strategy with integral terminal sliding mode observer (IT-SMO) to achieve high performance speed loop and current loop for permanent magnet synchronous motor (PMSM) drives. The modeling of PMSM considers the disturbance caused by parameter perturbation and permanent magnet demagnetization. With this model, we can derive the optimal control law of the proposed scheme, which avoids the tuning work of the weight factor effectively. This new CRFTPC strategy has a cascaded structure, external loop and internal loop, both implemented with robust fault-tolerant predictive control. In addition, a new integral terminal sliding mode observer is designed to estimate the disturbances, and thus the robustness of the proposed method can be increased significantly. Comparative simulations and experimentations verify that the proposed CRFTPC provides fast dynamic response, static-errorless speed, and current tracking, even with the system disturbance.

24 December 2018 in Energies
Verified
Journal Article
Open access
PDF file
CLChengwei Luo
Chengwei Luo
DLDerong Luo
Derong Luo
SHShoudao Huang
Shoudao Huang
ZRzhimeng Rao
zhimeng Rao
HZHongzhang Zhu
Hongzhang Zhu
QHQianjun He
Qianjun He
The dc-link voltage balance and reactive power equilibrium of the cascaded H-bridge rectifier (CHBR) are the prerequisites for the safe and stable operation of the system. However, the conventional PI (Proportional-Integral) control strategy only puts emphasis on the CHBR dc-link voltage balance without taking into account its reactive power equilibrium under capacitive and inductive working conditions. For this reason, this paper has proposed a novel control strategy for the CHBR that can not only balance dc-link voltage, but also achieve reactive power equilibrium and eliminate the coupling effect between the voltage-balancing controller (VBC) and original system controller (OSC). The control strategy can achieve dc-link voltage balance and the reactive power equilibrium of the CHBR through modifying the active duty cycle by closed loop control, and adjusting the reactive duty cycle relatively according to the modifiable amount of the active duty cycle. Moreover, the strategy can eliminate the coupling effect between the VBC and OSC by the open loop control modification of the active and reactive duty cycle of any H-bridge module in CHBR. Simulations and experiments have shown that the proposed control strategy is feasible and effective in performing the CHBR dc-link voltage balance and reactive power equilibrium under all working conditions and load variations.


15 September 2026 in World Electric Vehicle Journal
Verified
Journal Article
Open access
PDF file
YCYue Chang
Yue Chang
MLMing Lee
Ming Lee
YWYanwen Wang
Yanwen Wang
Lei ChenLei Chen
Lei Chen
CLChengwei Luo
Chengwei Luo
MLMincong Lin
Mincong Lin
Against the backdrop of the global energy crisis, hybrid vehicles offer greater energy saving potential. The equivalent consumption minimization strategy is an effective way to achieve energy savings for hybrid electric vehicles. This paper presents a fuzzy adaptive control method based on the equivalent consumption minimization strategy. To obtain a better SOC trajectory and lower equivalent fuel consumption, an adaptive adjustment algorithm for the equivalent fuel factor was designed, which incorporates a penalty function and a fuzzy adaptive method that accounts for SOC tracking errors. To verify the effectiveness of the proposed algorithm, this paper established a model of an HEV (hybrid electric vehicle) in Simulink and compared the proposed algorithm with the rule-based energy management strategy and the PI-based adaptive ECMS energy management strategy under different operating conditions. Compared with the rule-based and PI-based strategies, the proposed method improves the fuel economy by 1.01–4.64%, and the terminal SOC deviation is reduced from 0.0568–0.0619 to 0.0002–0.0010 under the UDDS and NYCC conditions.