zhimeng Rao

Mr. zhimeng Rao

Hunan University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
FHFang Hu
Fang Hu
DLDerong Luo
Derong Luo
CLChengwei Luo
Chengwei Luo
ZLZhuo Long
Zhuo Long
ZRzhimeng Rao
zhimeng Rao
This paper presents a cascaded robust fault-tolerant predictive control (CRFTPC) strategy with integral terminal sliding mode observer (IT-SMO) to achieve high performance speed loop and current loop for permanent magnet synchronous motor (PMSM) drives. The modeling of PMSM considers the disturbance caused by parameter perturbation and permanent magnet demagnetization. With this model, we can derive the optimal control law of the proposed scheme, which avoids the tuning work of the weight factor effectively. This new CRFTPC strategy has a cascaded structure, external loop and internal loop, both implemented with robust fault-tolerant predictive control. In addition, a new integral terminal sliding mode observer is designed to estimate the disturbances, and thus the robustness of the proposed method can be increased significantly. Comparative simulations and experimentations verify that the proposed CRFTPC provides fast dynamic response, static-errorless speed, and current tracking, even with the system disturbance.

30 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
MLMingcheng Lyu
Mingcheng Lyu
ZRzhimeng Rao
zhimeng Rao
DLDerong Luo
Derong Luo
FRFei Rong
Fei Rong
SHShoudao Huang
Shoudao Huang
This paper proposes a robust nonlinear predictive current control (RNPCC) method for permanent magnet synchronous motor (PMSM) drives, which can optimize the current control loop performance of the PMSM system with model parameter perturbation. First, the disturbance caused by parameter perturbation was considered in the modeling of PMSM. Based on this model, the influence of parameter perturbation on the conventional predictive current control (PCC) was analyzed. The composite integral terminal sliding mode observer (SMO) was then designed to estimate the disturbance caused by the parameter perturbation in real time. Finally, a RNPCC method is developed without relying on the mathematical model of PMSM, which can effectively eliminate the influence of parameter perturbation by injecting the estimated disturbance value. Simulations and experiments verified that the proposed RNPCC method was able to remove the current error caused by the parameter perturbation during steady state operation.

1 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
ZRZhimeng Rao
Zhimeng Rao
ZZZhigang Zhang
Zhigang Zhang
SHShoudao Huang
Shoudao Huang
ZLZhuo Long
Zhuo Long
ZRzhimeng Rao
zhimeng Rao
The permanent magnet synchronous generator (PMSG) is widely used in high voltage DC transmission technology of wind power systems due to its high-power density, high reliability and simple maintenance. To meet the increasing rated power of the generator (≥10 MW), the multi-converter parallel connection is usually used, which significantly increases the complexity and cost of the system. Therefore, a new modular N* three-phase PMSG is proposed in this paper. Based on the structure and working principle of the generator, the finite element model is established, and the electromagnetic properties are obtained by finite element analysis. Aiming at the unique winding structure and characteristics of modular N* three-phase PMSG, a generator side current converter harmonic control algorithm, combining a resonant controller with the proportional-integral regulator, is proposed. The suppression of stator current harmonics at different speeds could be achieved by the proposed algorithm, and the efficiency of the wind power generation system can be improved. Finally, the feasibility of the novel generator and the effectiveness of the proposed algorithm are verified by simulation and experiment.

1 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
WZWenjuan Zhang
Wenjuan Zhang
ZRzhimeng Rao
zhimeng Rao
ZRZhimeng Rao
Zhimeng Rao
JZJian Zheng
Jian Zheng
DLDerong Luo
Derong Luo
High power density energy storage permanent magnet (PM) motor is an important energy storage module in flywheel energy storage system for urban rail transit. To expand the application of the PM motor in the field of urban rail transit, a predictive power control (PPC) strategy for the N*3-phase PM energy storage motor is proposed in this paper. Firstly, the output characteristics of the N*3-phase PM energy storage motor are analyzed by using the finite element method, and the mathematical model of the N*3-phase PM energy storage motor is established. Then, the topological structure and operation principle of N*3-phase PM energy storage motor system is illustrated. Furthermore, the N*3-phase PM energy storage motor system driven by six parallel voltage source inverters (VSIs) is proposed to generate the required power. Finally, a novel predictive direct power control method is developed for the N*3-phase PM energy storage motor. The feasibility and effectively of the proposed PPC method are verified by experiment and simulation. Comprehensive simulation and experimental results both show that the proposed PPC method can obtain the lower torque/stator flux ripple, smaller values of THD of stator winding currents, and zero error tracking of stator winding flux.

24 December 2018 in Energies
Verified
Journal Article
Open access
PDF file
CLChengwei Luo
Chengwei Luo
DLDerong Luo
Derong Luo
SHShoudao Huang
Shoudao Huang
ZRzhimeng Rao
zhimeng Rao
HZHongzhang Zhu
Hongzhang Zhu
QHQianjun He
Qianjun He
The dc-link voltage balance and reactive power equilibrium of the cascaded H-bridge rectifier (CHBR) are the prerequisites for the safe and stable operation of the system. However, the conventional PI (Proportional-Integral) control strategy only puts emphasis on the CHBR dc-link voltage balance without taking into account its reactive power equilibrium under capacitive and inductive working conditions. For this reason, this paper has proposed a novel control strategy for the CHBR that can not only balance dc-link voltage, but also achieve reactive power equilibrium and eliminate the coupling effect between the voltage-balancing controller (VBC) and original system controller (OSC). The control strategy can achieve dc-link voltage balance and the reactive power equilibrium of the CHBR through modifying the active duty cycle by closed loop control, and adjusting the reactive duty cycle relatively according to the modifiable amount of the active duty cycle. Moreover, the strategy can eliminate the coupling effect between the VBC and OSC by the open loop control modification of the active and reactive duty cycle of any H-bridge module in CHBR. Simulations and experiments have shown that the proposed control strategy is feasible and effective in performing the CHBR dc-link voltage balance and reactive power equilibrium under all working conditions and load variations.