Zhenlin Wu

Dr. Zhenlin Wu


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2016 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Baomin WangBaomin Wang
Baomin Wang
RJRuishuang Jiang
Ruishuang Jiang
ZWZhenlin Wu
Zhenlin Wu
In this work, graphene nanoplatelets (GNPs) were dispersed uniformly in aqueous solution using methylcellulose (MC) as a dispersing agent via ultrasonic processing. Homogenous GNP suspensions were incorporated into the cement matrix to investigate the effect of GNPs on the mechanical behavior of cement paste. The optimum concentration ratio of GNPs to MC was confirmed as 1:7 by ultraviolet visible spectroscopy (UV-Vis), and the optical microscope and transmission electron microscopy (TEM) images displayed remarkable dispersing performance. The GNP–cement composite exhibited better mechanical properties with the help of surface-modified GNPs. The flexural strength of cement paste increased up to 15%–24% with 0.05 wt % GNPs (by weight of cement). Meanwhile, the compressive strength of the GNP–cement composite increased up to 3%–8%. The X-ray diffraction (XRD) and thermal analysis (TG/DTG) demonstrated that the GNPs could accelerate the degree of hydration and increase the amount of hydration products, especially at an early age. Meanwhile, the lower porosity and finer pore size distribution of GNP–cement composite were detected by mercury intrusion porosimetry (MIP). In addition, scanning electron microscope (SEM) analysis showed the introduction of GNPs could impede the development of cracks and preserve the completeness of the matrix through the plicate morphology and tortuous behavior of GNPs.

28 May 2018 in Materials
Verified
Journal Article
Open access
PDF file
TZTingting Zhang
Tingting Zhang
JZJing Zou
Jing Zou
Baomin WangBaomin Wang
Baomin Wang
ZWZhenlin Wu
Zhenlin Wu
YJYuan Jia
Yuan Jia
Christopher CheesemanChristopher Cheeseman
Christopher Cheeseman
Magnesium silicate hydrate (MSH) gel was formed by reacting magnesium oxide (MgO) with silica fume (SF) in distilled water. The MSH was prepared using a MgO/SF molar ratio of 1.0 (40:60 weight ratio). Samples were analyzed during hydration process up to 300 days at room temperature. The MSH characterization has been carried out using a range of analytical techniques. Quantitative analysis was achieved using thermogravimetric analysis (TG/DTG) with a de-convolution technology. The structure of MSH gel was characterized using solid state nuclear magnetic resonance (29Si NMR) and Fourier transform infrared (FT-IR) spectroscopy. Transmission electron microscopy (TEM) was used to investigate MSH microstructure. Compared with natural magnesium silicate hydrate minerals, the structure of MSH gel is highly disordered and generates on the surface of particles, producing a shell structure with cavity. The molecular structure of MSH phase is layered. The results also show that the extent of polymerization of MSH gel is related to the solution pH during hydration.

22 March 2019 in Polymers
Verified
Journal Article
Open access
PDF file
ZWZhenlin Wu
Zhenlin Wu
YQyanan Qi
yanan Qi
XYXiao-Jie Yin
Xiao-Jie Yin
XYXin Yang
Xin Yang
CCChangming Chen
Changming Chen
MZMing-Shan Zhao
Ming-Shan Zhao
Polymer materials exhibit unique properties in the fabrication of optical waveguide devices, electromagnetic devices, and bio-devices. Direct laser writing (DLW) technology is widely used for micro-structure fabrication due to its high processing precision, low cost, and no need for mask exposure. This paper reviews the latest research progresses of polymer-based micro/nano-devices fabricated using the DLW technique as well as their applications. In order to realize various device structures and functions, different manufacture parameters of DLW systems are adopted, which are also investigated in this work. The flexible use of the DLW process in various polymer-based microstructures, including optical, electronic, magnetic, and biomedical devices are reviewed together with their applications. In addition, polymer materials which are developed with unique properties for the use of DLW technology are also discussed.

1 October 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Yang ZhangYang Zhang
Yang Zhang
FWFang Wang
Fang Wang
SQSiyu Qian
Siyu Qian
ZLZexu Liu
Zexu Liu
QWQiao Wang
Qiao Wang
PWPeng Wei
Peng Wei
We proposed and demonstrated a novel tilted fiber Bragg grating (TFBG)-based surface plasmon resonance (SPR) label-free biosensor via a special boronic acid derivative to detect glycoprotein with high sensitivity and selectivity. TFBG, as an effective sensing element for optical sensing in near-infrared wavelengths, possess the unique capability of easily exciting the SPR effect on fiber surface which coated with a nano-scale metal layer. SPR properties can be accurately detected by measuring the variation of transmitted spectra at optical communication wavelengths. In our experiment, a 10° TFBG coated with a 50 nm gold film was manufactured to stimulate SPR on a sensor surface. To detect glycoprotein selectively, the sensor was immobilized using designed phenylboronic acid as the recognition molecule, which can covalently bond with 1,2- or 1,3-diols to form five- or six-membered cyclic complexes for attaching diol-containing biomolecules and proteins. The phenylboronic acid was synthetized with long alkyl groups offering more flexible space, which was able to improve the capability of binding glycoprotein. The proposed TFBG-SPR sensors exhibit good selectivity and repeatability with a protein concentration sensitivity up to 2.867 dB/ (mg/mL) and a limit of detection (LOD) of 15.56 nM.

31 May 2018 in Polymers
Verified
Journal Article
Open access
PDF file
XHXiuyou Han
Xiuyou Han
ZWZhenlin Wu
Zhenlin Wu
SYSi-Cheng Yang
Si-Cheng Yang
FSFang-Fang Shen
Fang-Fang Shen
YLYuxin Liang
Yuxin Liang
MZMing-Shan Zhao
Ming-Shan Zhao
Polymers are promising materials for fabricating photonic integrated waveguide devices. Versatile functional devices can be manufactured using a simple process, with low cost and potential mass-manufacturing. This paper reviews the recent progress of polymer photonic integrated devices fabricated using the UV imprinting technique. The passive polymer waveguide devices for wavelength filtering, power splitting, and light collecting, and the active polymer waveguide devices based on the thermal-optic tuning effect, are introduced. Then, the electro-optic (EO) modulators, by virtue of the high EO coefficient of polymers, are described. Finally, the photonic biosensors, which are based on low-cost and biocompatible polymer platforms, are presented.

21 February 2019 in IEEE Photonics Journal
Verified
Journal Article
Open access
YLYuxin Liang
Yuxin Liang
MZMing-Shan Zhao
Ming-Shan Zhao
ZWZhenlin Wu
Zhenlin Wu
GMGeert Morthier
Geert Morthier
A refractive index sensor based on bimodal waveguide interferometer is demonstrated on the low-cost polymer platform for the first time. Different from conventional interferometers which make use of the interference between the light from two arms, bimodal waveguide interferometers utilize the interference between the two different internal modes in the waveguide. Since the utilized first higher mode has a wide evanescent tail which interacts with the external environment, the interferometer can reach a high sensitivity. Instead of vertical bimodal structure which is normally employed, the lateral bimodal waveguide is adopted in order to simplify the fabrication process. An unique offset between the centers of single mode waveguide and bimodal waveguide is designed to excite the two different modes with equal power which contributes to the maximum fringe visibility. The bimodal waveguide interferometer is finally fabricated on optical polymer (Ormocore) which is transparent at both infrared and visible wavelengths. It is fabricated using the UV-based soft imprint technique which is simple and reproductive. The bulk sensitivity of fabricated interferometer sensor with a 5 mm sensing length is characterized using different mass concentration sodium chloride solutions. The sensitivity is obtained as 316 Πrad/RIU and the extinction ratio can reaches 18 dB.