Margarita Valenzuela-Galván

Dr. Margarita Valenzuela-Galván

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Ingeniería Investigación y Tecnología
Verified
Journal Article
Closed access
ACAna Victoria Marín Calderón
Ana Victoria Marín Calderón
MVMargarita Valenzuela-Galván
Margarita Valenzuela-Galván
GCGuillermo Cuamea Cruz
Guillermo Cuamea Cruz
AAAgustin Brau Avila
Agustin Brau Avila
La metodología Lean Six Sigma es popularmente conocida en el giro industrial como una forma de reducir la variación en los procesos productivos, donde, mediante el uso de herramientas de las filosofías Esbelta y Seis Sigma, se busca mejorar la calidad de los productos o servicios al menor coste posible. Si bien existen diferentes estrategias, Lean Six Sigma se ha vuelto sumamente llamativa en los últimos años por la eficiencia y magnitud de sus resultados. En este trabajo se presenta la aplicación de dicha metodología en una empresa dedicada a la fabricación de artículos de construcción, donde, el enfoque se ha dirigido al área de páneles modulares con el fin de reducir el alto porcentaje de desperdicios presentados. Durante la aplicación se logró identificar diferentes variables que poseían un efecto significativo en el producto final, de esta manera, fue posible determinar las mejores herramientas que apoyaran al proceso productivo para mejorarlo y finalmente controlarlo. Entre estas herramientas se encuentran dos estudios R&R, los cuales, identificaron que el sistema de medición poseía un 81% de confiabilidad y confirmaron su incremento al 98% después de las mejoras aplicadas. Asimismo, se desarrolló un diseño de experimentos que estableció un nuevo estándar para disminuir el principal defecto presentado en el producto, logrando obtener un modelo matemático capaz de predecir respuestas a nuevas observaciones en un 90.45%. Finalmente, después de 3 meses de observación se obtuvo una reducción del 66% de los DPMO, lo que confirmó la efectividad de la metodología y la magnitud de sus beneficios.

31 August 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MGMarta Torralba Gracia
Marta Torralba Gracia
LDLucía Díaz-Pérez
Lucía Díaz-Pérez
MVMargarita Valenzuela-Galván
Margarita Valenzuela-Galván
JAJose Antonio Albajez
Jose Antonio Albajez
Jose Antonio Yague FabraJose Antonio Yague Fabra
Jose Antonio Yague Fabra
This article presents a self-calibration procedure and the experimental results for the geometrical characterisation of a 2D laser system operating along a large working range (50 mm × 50 mm) with submicrometre uncertainty. Its purpose is to correct the geometric errors of the 2D laser system setup generated when positioning the two laser heads and the plane mirrors used as reflectors. The non-calibrated artefact used in this procedure is a commercial grid encoder that is also a measuring instrument. Therefore, the self-calibration procedure also allows the determination of the geometrical errors of the grid encoder, including its squareness error. The precision of the proposed algorithm is tested using virtual data. Actual measurements are subsequently registered, and the algorithm is applied. Once the laser system is characterised, the error of the grid encoder is calculated along the working range, resulting in an expanded submicrometre calibration uncertainty (k = 2) for the X and Y axes. The results of the grid encoder calibration are comparable to the errors provided by the calibration certificate for its main central axes. It is, therefore, possible to confirm the suitability of the self-calibration methodology proposed in this article.

14 October 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AOAngel Oviedo
Angel Oviedo
OIOctavio Icasio-Hernandez
Octavio Icasio-Hernandez
MVMargarita Valenzuela-Galván
Margarita Valenzuela-Galván
Victor BenitezVictor Benitez
Victor Benitez
AAAgustin Brau Avila
Agustin Brau Avila
Manual inspection in the high-precision manufacturing industry often struggles to meet the demands of high-volume production and strict dimensional tolerances. This paper presents a vision-based measurement system for the automated inspection of CNC-turned parts. The methodology integrates a custom-built, isolated backlit inspection station and sub-pixel edge detection algorithms developed in Python/OpenCV. Optical calibration was configured through a 22 full factorial design of experiments, yielding a ground sample distance of 0.0323 mm/px and a mean reprojection error of 0.093 px. Validation against a coordinate measuring machine on a 108-part batch showed a root mean square error below 0.0260 mm for all dimensions. Error sources were quantified through stability tests, a gauge R&R study, and an uncertainty budget. Overall classification accuracy was 99.1%, 95.4%, and 92.6% at tolerances of ±0.0762, ±0.0508, and ±0.0254 mm, respectively, with sensitivity of at least 97.4% and positive predictive value between 76.2% and 92.6%. The system inspects 100% of the parts, evaluating five dimensions in 4.72 s per piece, over 81% faster than manual inspection, with full digital traceability.