Changjin Jung

Dr. Changjin Jung


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
MJMin-Ho Jun
Min-Ho Jun
YKYoung-Min Kim
Young-Min Kim
JBJang-Han Bae
Jang-Han Bae
CJChangjin Jung
Changjin Jung
JCJung-Hee Cho
Jung-Hee Cho
YJYoung-Ju Jeon
Young-Ju Jeon
The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB) as one of the sensor combination methods. The three-layered housing structure that included independent pressure sensor units using the FDB method not only enabled elimination of the crosstalk among channels, but also allowed various array patterns to be created for effective pulse measurement. The sensors were arranged in a circular-type arrangement such that they could estimate the direction of the radial artery and precisely measure the pulse wave. The performance of the fabricated sensor array was validated by evaluating the sensor sensitivity per channel, and the possibility of estimating the blood vessel direction was demonstrated through a radial artery pulse simulator. We expect the proposed sensor to allow accurate extraction of the pulse indices for pulse diagnosis.

15 January 2014 in BMC Complementary and Alternative Medicine
Verified
Journal Article
Open access
PDF file
YKYoung-Min Kim
Young-Min Kim
BKBoncho Ku
Boncho Ku
CJChangjin Jung
Changjin Jung
Jaeuk KimJaeuk Kim
Jaeuk Kim
YJYoung-Ju Jeon
Young-Ju Jeon
JKJong Yeol Kim
Jong Yeol Kim
Human skin properties have been used as an important diagnostic component in traditional medicine as they change with health conditions. Sasang constitutional medicine (SCM) puts emphasis on the recognition of the constitution-specific skin features prior to the diagnostic decision of health. In this work, in search of skin-characteristics effectively reflecting SCM features, we compared several skin properties such as perspiration, visco-elasticity, elasticity, and elasticity hysteresis, in several candidate body parts. We conducted a clinical study in which a total of 111 healthy females aged 50 – 70 years participated with their Sasang constitution (SC) types determined objectively by the Sasang constitutional analytic tool. Perspiration on the skin surface was estimated by using a capacitance sensor to measure the amount of moisture on the palm, forehead, and philtrum before and after a heating stimulus. We acquired the visco-elasticity, elasticity, and elasticity hysteresis at the forearm by Dermalab’s elasticity sensing device. An analysis of covariance (ANCOVA) was conducted to evaluate the effect of SC on the nine skin features acquired. The visco-elasticity of the forearm of the Soeum-in (SE) group was significantly lower than that of the Taeeum-in (TE) group (F = 68.867, p < 0.001), whereas the elasticity hysteresis of the SE group was higher than that of the TE group (F = 10.364, p < 0.01). The TE group had more perspiration on the forehead than the SE group (F = 9.050, p < 0.01). The SE group had a large perspiration difference between the philtrum and the forehead compared with the TE group (F = 7.892, p < 0.01). We found four significant skin features that reflect the inherent constitutional attributes of the TE and SE groups in accordance with SCM literature; the visco-elasticity, elasticity hysteresis, perspiration on the forehead and philtrum. Our findings are based on a novel interpretation of the SCM literature and will contribute to developing the constitutional health status evaluation system in SCM.