Hassan Abdolpour

Dr. Hassan Abdolpour


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2016 in Composite Structures
Verified
Journal Article
Closed access
HAHassan Abdolpour
Hassan Abdolpour
JGJulio Garzón-Roca
Julio Garzón-Roca
GEGonçalo Escusa
Gonçalo Escusa
JSJosé M. Sena-Cruz
José M. Sena-Cruz
JBJoaquim António Oliveira de Barros
Joaquim António Oliveira de Barros
MVMaria Isabel Brito Valente
Maria Isabel Brito Valente

1 August 2022 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Open access
PDF file
HAHassan Abdolpour
Hassan Abdolpour
PNPaweł Niewiadomski
Paweł Niewiadomski
Łukasz SadowskiŁukasz Sadowski
Łukasz Sadowski
AKArkadiusz Kwiecień
Arkadiusz Kwiecień
The main novelty of this study is producing Ultra High-Performance Self Compacting Mortar (UHPSCM) incorporated Recycled Steel Fibre (RSF) from waste tires. For this purpose, different mix compositions including 0%, 1%, and 3% RSF content in terms of volume were proposed. Self-compacting ability was assessed using mini-cone tests, while nondestructive testing has been used to evaluate the effect of RSF inclusion on the compaction of UHPSCM constituent materials. Mechanical performances were investigated using compression and unnotched flexural tests. Residual flexural strength in both service limit state (SLS), ultimate limit state (ULS), and two equivalent flexural strengths were evaluated under notched flexural tests and analysed using statistical approaches. Concrete Damage Plasticity (CDP) has been employed for the analysis behaviour of developed mortars under different loadings. Additionally, an element deletion approach was used to evaluate the fracture of UHPSCM under compression and flexural loadings. The experimental results showed that adding 1% and 3% of RSF resulted in decreasing workability by 3% and 22%, respectively. Improving compressive strength by 16% and 22% and flexural by 7% and 8% were noticed in the case of samples with 1% and 3% fiber, respectively, in 28 days. In spite of the significant improvement of post-cracking behaviour of samples with 3% of RSF, this behaviour was insignificant for the samples with 1% of RSF. However, with less amount of fibre inclusion, brittle failure can be altered to ductile failure. Moreover, the behaviour of the tested specimens under different loadings was successfully predicted using Finite Element (FE) simulations. Graphical abstract

4 August 2022 in Journal of Cleaner Production
Verified
Journal Article
Open access
HAHassan Abdolpour
Hassan Abdolpour
PNPaweł Niewiadomski
Paweł Niewiadomski
Łukasz SadowskiŁukasz Sadowski
Łukasz Sadowski
ACAgnieszka Ewa Chowaniec-Michalak
Agnieszka Ewa Chowaniec-Michalak

1 August 2017 in Journal of Composites for Construction
Verified
Journal Article
Closed access
HAHassan Abdolpour
Hassan Abdolpour
GEGoncalo Escusa
Goncalo Escusa
Jose Sena-CruzJose Sena-Cruz
Jose Sena-Cruz
MVMaria Isabel Brito Valente
Maria Isabel Brito Valente
JBJoaquim António Oliveira de Barros
Joaquim António Oliveira de Barros
Throughout this paper, a new system for connecting composite sandwich wall panels is proposed. The relevant structural components are investigated with the aim of utilizing these panels as insulated wall elements in building applications or prefabricated modular systems. The adopted sandwich wall panels are composed of hand-layup glass fiber–reinforced polymer (GFRP) outer skins and low-density closed polyurethane (PU) foam core. The sandwich wall panels present an overall geometry of 2,880×960×64  mm3 . One challenge of the proposed new system that was examined included joining the panels in the longitudinal direction (along their height) and transversally connecting (along their width) to other structural elements, similar to beams at the bottom and top. The structural performance of the sandwich wall panels was experimentally tested and thereafter analytically assessed in two cases: (1) single wall panels; and (2) two jointed wall panels. Outward localized GFRP wrinkling, followed by global buckling was observed as the dominant failure mode in both cases. Further, the capability of the proposed connection system to increase the axial load capacity of the jointed panels was evaluated. The study illustrates that axial capacity of two jointed sandwich wall panels, compared to the single sandwich wall panel, increased substantially from 91 to 152% depending on the failure modes.

28 September 2017 in Journal of Composite Materials
Verified
Journal Article
Closed access
HAHassan Abdolpour
Hassan Abdolpour
JGJulio Garzón-Roca
Julio Garzón-Roca
GEGonçalo Escusa
Gonçalo Escusa
JSJosé M Sena-Cruz
José M Sena-Cruz
JBJoaquim António Oliveira de Barros
Joaquim António Oliveira de Barros
MVMaria Isabel Brito Valente
Maria Isabel Brito Valente
The present paper explores a new modular floor prototype to be used in emergency houses. The prototype is composed of a frame structure made of glass-fibre-reinforced polymer tubular pultruded profiles, a slab made of sandwich panels with a polyurethane foam core and glass-fibre-reinforced polymer skins, and a tailored connection system that provides integrity between assembled components. A series of experimental tests are carried out including flexural tests on a single panel, on two and three connected panels, and on the assembled floor prototype. The behaviour of the panels is analysed when they are not considered part of the glass-fibre-reinforced polymer framed structure, namely the failure mechanisms and the efficiency of the proposed connection system between the panels. The performance of the floor prototype to support typical load conditions of residential houses is also assessed. Additionally, an analytical model was used to deeper study the behaviour of the developed sandwich panels, connection system and the modular floor prototype.

7 June 2018 in Journal of Composite Materials
Verified
Journal Article
Closed access
HAHassan Abdolpour
Hassan Abdolpour
JGJulio Garzón-Roca
Julio Garzón-Roca
PMPouya Hmh Mameghani
Pouya Hmh Mameghani
The present paper explores different techniques for increasing flexural performance of composite sandwich panels made of hand-layup glass fiber reinforced polymer skins and low density closed cell polyurethane foam core. An experimental program compares the performance of simple panels face to the use of transversal and longitudinal internal glass fiber reinforced polymer ribs and the installation of a strain hardening cementitious base composite top layer over the panels. Based on the experimental results, finite element models are also developed to simulate the flexural behavior of tested panels and conducted an in depth analysis of the techniques studied. Obtained experimental and numerical results show that the use of internal glass fiber reinforced polymer ribs (especially in longitudinal direction) along with the use of strain hardening cementitious base composite significantly and effectively increases the flexural performance of sandwich panels. The high stiffness to weight ratio capacity of the panels attained by applying the proposed method enables its use in rehabilitation of historical places. Furthermore, the proposed techniques could be helpful for strengthening available composite sandwich panels.