Tohid Rahimi

Dr. Tohid Rahimi

Department of Electronics, Carleton University, Ottawa, ON, Canada
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2021 in IEEE Access
Verified
Journal Article
Open access
Tohid RahimiTohid Rahimi
Tohid Rahimi
LDLei Ding
Lei Ding
HGHossein Gholizadeh
Hossein Gholizadeh
RSReza Sharifi Shahrivar
Reza Sharifi Shahrivar
RFRasoul Faraji
Rasoul Faraji
This paper presents a novel design of step-up DC-DC converters whose merits are: (i) The continuity of the input current has been kept; (ii) The polarity of the output voltage has been kept positive which provides the same ground of the input source and load; (iii) The low voltage gain of the quadratic converters has been solved that it can increase the input voltage to 10 times more by the low value of the duty cycle; (iv) Apart from the high value of the voltage gain, the semiconductors’ voltage and current stresses were lower than the output voltage and input current of the converter which are the highest value of the voltage and current respectively and semiconductor based components do not suffer from high value of the current/voltage stresses; (v) Additionally, the voltage/current stresses are low, and the efficiency is good according to its 90 percent value. The analysis of the non-ideal voltage gain has been done and its better function has been deduced by comparing it with the recently proposed non-isolated topologies. Additionally, the non-isolated voltage gain has been studied for different output power levels. The efficiency has been extracted and discussed for varying duty cycles and output power based on ignoring some losses. Experimental results and simulation outcomes from the PLECS software have been compared along with theoretical relationships. The prototype of the topology has been tested at 100 W output power, 100 V output voltage, and 10 V input voltage.

19 May 2021 in IEEE Access
Verified
Journal Article
Open access
Tohid RahimiTohid Rahimi
Tohid Rahimi
LDLei Ding
Lei Ding
MKMostafa Kheshti
Mostafa Kheshti
RFRasoul Faraji
Rasoul Faraji
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Gibran David Agundis TinajeroGibran David Agundis Tinajero
Gibran David Agundis Tinajero
Due to the high penetration of renewable energy resources in microgrids (MGs), the grid inertia becomes low which leads to the grid to be vulnerable to large disturbances. The energy storage devices can play an important role to enhance the inertia of MGs. However, due to the high investment cost of storages or their dp/dt limitation, the installed energy storages cannot cover the challenge of high df/dt. A prominent solution to solve the problem is to use the inertia response of the wind generators. However, relatively high second frequency nadir is the main drawback of using the inertia response of the wind generators which may impose an extensive disturbance to MGs. Accordingly, a coordinated operation strategy for MGs between wind generator and hybrid energy storage (HES) system is proposed in this paper. In addition, to improve the inertia response of the MG; providing high-quality communication infrastructures with low delay and increasing the Ultracapacitor capacity have been paid attention. In this paper, the costs of the installed Ultracapacitor and quality of communication services are defined as the operation cost. Guaranteeing enough frequency damping for the MG with low operation cost are two conflict objectives. Therefore, a multi-objective optimization method is used to set the controllers' values and reduce the operation cost. The results confirmed that the effectiveness of the proposed strategy to control hybrid power storage in coordination with the wind generator and the frequency recovery process is improved. Also, employing the optimum values guaranteed the frequency damping effectively with low operation cost. The Integral Absolute Error (IAE) value and operation cost are reduced by 13.6% and 32%, respectively. Also, the simulation results show that the maximum MG frequency deviation and maximum df/dt is well compatible with different standards in the presence of load perturbations and different wind speeds.

28 April 2021 in IEEE Access
Verified
Journal Article
Open access
RFRasoul Faraji
Rasoul Faraji
LDLei Ding
Lei Ding
Tohid RahimiTohid Rahimi
Tohid Rahimi
MKMostafa Kheshti
Mostafa Kheshti
Md. Rabiul IslamMd. Rabiul Islam
Md. Rabiul Islam
In this paper, a new high efficiency soft-switching non-isolated three-port converter (TPC) is proposed. In the conventional TPC, three switches are required to process power in different directions between inputs and output. Providing soft-switching condition for all switches using a low number of auxiliary components is a challenging task. In this paper, the conventional TPC topology is modified by changing its structure and adding a simple auxiliary circuit such that all switches operate under soft-switching condition in all operating modes. To reduce the volume of the converter, the magnetic components are integrated using a coupled inductor in the auxiliary soft-switching cell. In this paper, various converter operating modes are presented, and design considerations are discussed. Finally, a prototype 200 W, 100 V converter is implemented in the laboratory, and the theoretical analysis is validated by the experimental results.

26 September 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Tohid RahimiTohid Rahimi
Tohid Rahimi
Md. Rabiul IslamMd. Rabiul Islam
Md. Rabiul Islam
Hossein GholizadehHossein Gholizadeh
Hossein Gholizadeh
SMSaeed Mahdizadeh
Saeed Mahdizadeh
EAEbrahim Afjei
Ebrahim Afjei
This paper introduces a novel topology of the proposed converter that has these merits: (i) the topology of the converter is based on conventional boost and buck-boost converters, which has caused its simplicity; (ii) the voltage gain of the converter has provided higher values by the lower value of the duty cycle; (iii) due to the use of high-efficiency conventional topologies in its structure, the efficiency of the converter keeps its high value for a great interval of duty cycle; (iv) besides the increase of the voltage gain, the current/voltage stresses of the semiconductors have been kept low; (v) the continuous input current of this converter reduces the current stress of the capacitor in the input filter. It is worth noting that the proposed converter has been discussed in both ideal and non-ideal modes. Moreover, the operation of the converter has been discussed in both continuous/discontinuous current modes. The advantages of the converter have been compared with recently suggested converters. In addition, the different features of the converter have been discussed for different conditions. In the small-signal analysis, the appropriate compensator has been designed. Finally, the simulation and experimental results have been reported for 90 W output power, 90 V output voltage, 3-times voltage gain, and 100 kHz switching frequency.

19 May 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
RFRasoul Faraji
Rasoul Faraji
LDLei Ding
Lei Ding
Tohid RahimiTohid Rahimi
Tohid Rahimi
MKMostafa Kheshti
Mostafa Kheshti
In this article, the inherent fault-tolerant capability of the soft-switching cell for boost-based dc-dc converters is investigated. The main switch of boost-based dc-dc converters withstands high-temperature stress, which is expected to be failed with a higher probability than other devices. Providing soft-switching condition for the main switch and employing fault-tolerant capability are effective approaches to solve this problem. When a fault occurs for the main switch, the proposed converter can be reconfigured such that the soft-switching cell can change its duty to continue the normal operation of the converter without interruption. Inherent redundancy, low failure rate, high integration, and high efficiency are the specifications of the presented converter. The reliability analyses are presented and the functionality of the active soft-switching cell to provide soft-switching condition and fault-tolerant capability are verified by experimental results.

19 August 2022 in Symmetry
Verified
Journal Article
Open access
PDF file
Darioush RazmiDarioush Razmi
Darioush Razmi
ZZZhenbin Zhang
Zhenbin Zhang
ADAlireza Davari
Alireza Davari
Tohid RahimiTohid Rahimi
Tohid Rahimi
YMYuntao Miao
Yuntao Miao
ZZZhenbin Zhang
Zhenbin Zhang
In recent years, in response to increasing environmental concerns, advances in renewable energy technology and reduced costs have caused a significant increase in the penetration of distributed generation resources in distribution networks. Nonetheless, the connection of distributed generation resources to distribution networks has created new challenges in the control, operation, and management of network reliability. This article is a review on the model predictive control (MPC) for distributed energy resources (DER) in microgrids. The solutions of MPC for energy conversion of solar photovoltaic, wind, and energy storage systems are covered in detail. MPC’s applications for increasing reliability of grid-connected converters under (a)symmetrical grid faults are also discussed. The promising potentials of the applications of MPC to the stable multi-variable control performance of DERs are highlighted. This work reflects strong symmetry on MPC control strategies and provides guidance map for readers to facilitate future research works in these exciting fields.
1