Habiba Begum

Habiba Begum

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2021 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
HBHabiba Begum
Habiba Begum
JQJingui Qian
Jingui Qian
Joshua LeeJoshua Lee
Joshua Lee
This paper investigates the characteristics of higher-order transverse mode fully clamped membrane resonators that are piezoelectrically transduced as a class of resonators that completely seal the domain above the resonator from the domain below. Such isolation between the top and bottom of a resonator is preferable when encasing the device in a microfluidic cell for liquid-phase sensing measurements, a setup that can be beneficial for sensing applications. Most fully clamped membrane resonators are hampered by low liquid-phase quality factor ( Q ) and large motional resistance ( R m ). This paper describes the design of higher-order transverse (2, 2) mode square membrane and (2, 0) mode circular membrane resonators, and the effect of device scaling on liquid-phase Q and R m . We show a best-case liquid-phase R m of 54 kΩ and Q of 270 among the various membrane sizes tested. This level of liquid-phase Q is higher than some contour mode resonators. Compared to other fully clamped membrane resonators in the literature, the results here represent a significant improvement in both R m and Q , highlighting the potential of these membrane resonators for liquid-phase mass sensing applications.

25 March 2022 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
JQJingui Qian
Jingui Qian
HBHabiba Begum
Habiba Begum
Joshua LeeJoshua Lee
Joshua Lee
We have developed a hybrid device that fuses the techniques of acoustofluidic localization and resonator-based mass sensing of particles in liquid-phase for in-situ analysis in a $\mu \text{L}$ droplet. An elliptic plate resonator (EPR) was used in this work to verify the capability of acoustofluidic manipulation on a resonator chip. Particles were focused on the EPR by the acoustic tweezers to increase the effectiveness of detection. The EPR has a reasonably high liquid-phase quality factor ( ${Q}$ ) and low motional resistance ( ${R}_{m}$ ) to allow the detection of focused particles in liquid. Moreover, the resonator chip can be detached from the acoustic tweezing device without damage. This allows replacement of just the chip when required. A potential application of this work is organizing and sensing cells on-chip using the concepts herein.

3 January 2025 in Applied Physics Reviews
Verified
Journal Article
Closed access
JQJingui Qian
Jingui Qian
YWYue Wang
Yue Wang
YXYuhang Xue
Yuhang Xue
HBHabiba Begum
Habiba Begum
RFRichard Fu
Richard Fu
Joshua LeeJoshua Lee
Joshua Lee
Micro- and nano-electromechanical systems resonators have been regarded as powerful tools for precision mass detection, and their abilities to measure these in a liquid environment open various opportunities for biosensing, chemical analysis, and environmental monitoring. Apart from overcoming issues of fluidic damping and electrical interfaces, there is a great challenge of bringing microanalytes to these devices with the required precision and scaling for high throughput sensing. Herein, we address the above challenges by proposing a self-excited localized acoustic manipulation methodology based on a piezoelectric micromechanical diaphragm resonator (PMDR). Such a PMDR integrates acoustofluidics and mass sensing functions in tandem on a single device. Particle enrichment is realized within tens of seconds and the limit of detection is enhanced by mitigating common issues such as low capture rate and non-uniform distribution. The developed PMDR is versatile in its applicability to a range of particle sizes and densities for both acoustofluidic actuation and in situ mass sensing. This work addresses long-term technical challenges of inaccurate and inefficient measurement of liquid phase resonance mass sensing with great application potentials in biochemical detection and environmental monitoring.

19 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Marco BauMarco Bau
Marco Bau
Marco FerrariMarco Ferrari
Marco Ferrari
HBHabiba Begum
Habiba Begum
AAAbid Ali
Abid Ali
Joshua LeeJoshua Lee
Joshua Lee
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari
A technique and electronic circuit for contactless electromagnetic interrogation of piezoelectric micro-electromechanical system (MEMS) resonator sensors are proposed. The adopted resonator is an aluminum-nitride (AlN) thin-film piezoelectric-on-silicon (TPoS) disk vibrating in radial contour mode at about 6.3 MHz. The MEMS resonator is operated in one-port configuration and it is connected to a spiral coil, forming the sensor unit. A proximate electronic interrogation unit is electromagnetically coupled through a readout coil to the sensor unit. The proposed technique exploits interleaved excitation and detection phases of the MEMS resonator. A tailored electronic circuit manages the periodic switching between the excitation phase, where it generates the excitation signal driving the readout coil, and the detection phase, where it senses the transient decaying response of the resonator by measuring through a high-impedance amplifier the voltage induced back across the readout coil. This approach advantageously ensures that the readout frequency of the MEMS resonator is first order independent of the interrogation distance between the readout and sensor coils. The reported experimental results show successful contactless readout of the MEMS resonator independently from the interrogation distance over a range of 12 mm, and the application as a resonant sensor for ambient temperature and as a resonant acoustic-load sensor to detect and track the deposition and evaporation processes of water microdroplets on the MEMS resonator surface.

1 June 2019
Verified
Conference Paper
Closed access
HBHabiba Begum
Habiba Begum
AAAbid Ali
Abid Ali
Joshua LeeJoshua Lee
Joshua Lee
We present, for the first time, mass sensitivity measurements of a novel resonant mode based on a disk resonator that delivers the one of the highest Q-factors among resonators tested in liquid (Q of 362). The mode of interest is referred to as the Button-like (BL) mode as its associated lateral strain profile resembles a shirt button. In the context of mass sensing, the high Q-factor of the BL mode enhances mass resolution. Its motional resistance (R m ) in water is 5.3kΩ, which greatly eases the difficulty in designing control circuits. In this paper, we measured the mass sensitivity of the device by depositing chrome (Cr) on the bottom surface of the device through a back cavity. The resonator has a measured mass sensitivity of 17.2ppm/ng for uniformly deposited mass on the resonator’s surface.

25 December 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HBHabiba Begum
Habiba Begum
JQJingui Qian
Jingui Qian
Joshua LeeJoshua Lee
Joshua Lee
Key to realizing practical resonators for liquid-phase sensing applications is efficient electromechanical transduction and reasonable Q in liquid, which determine the motional resistance (Rm). Both lower Rm and high liquid phase Q are important for realizing a more stable close-loop oscillator to allow a lower detection limit. But Rm usually increases when scaling down resonator size, leading to weak output signals in liquid. This paper describes a piezoelectrically transduced micromechanical elliptical plate resonator (EPR) targeting liquid-phase sensing applications. The proposed EPR delivers lower Rm relative to other disk-based modes and has a reasonable Q in water. These two features are critical for eventually realizing a closed-loop system to enable real-time frequency tracking for sensing applications. The low Rm arises from enhanced transduction efficiency associated with the modal lateral strain profile. The EPR’s moderate liquid phase Q stems from transducing a stiff lateral bulk mode that increases energy storage. The proposed EPR can be scaled down more efficiently compared to other disk-based modes in the limit of mode shape distortion by anchors when scaling down the resonator below a threshold. Experimental results in water are demonstrated for a 500 μm by 400 μm EPR, which delivers an Rm of only 2.68 kΩ in water without feedthrough cancellation. Scaling down the device to 300 μm by 200 μm, we demonstrate an Rm of just 5.5 kΩ and Q of 245 in water. The proposed EPR topology boasts the lowest Rm among resonators immersed in liquid after normalizing over the device area.