Marco Bau

Dr. Marco Bau

Department of Information Engineering (DII), University of Brescia, Via Branze 38, I 25123 Brescia, Italy
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2011 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
Marco FerrariMarco Ferrari
Marco Ferrari
Marco BauMarco Bau
Marco Bau
MGM. Guizzetti
M. Guizzetti
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari

1 August 2010 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
BAB. Andò
B. Andò
SBS. Baglio
S. Baglio
Marco BauMarco Bau
Marco Bau
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari
Emilio SardiniEmilio Sardini
Emilio Sardini
CTC. Trigona
C. Trigona

1 August 2018 in AEU - International Journal of Electronics and Communications
Verified
Journal Article
Closed access
MDMarco Demori
Marco Demori
Marco BauMarco Bau
Marco Bau
Marco FerrariMarco Ferrari
Marco Ferrari
VFVittorio Ferrari
Vittorio Ferrari

9 September 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
MDMarco Demori
Marco Demori
Marco BauMarco Bau
Marco Bau
Marco FerrariMarco Ferrari
Marco Ferrari
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari
Coil-coupled passive sensors can be interrogated without contact, exploiting the magnetic coupling between two coils forming a telemetric proximity link. A primary coil connected to the interface circuit forms the readout unit, while a passive sensor connected to a secondary coil forms the sensor unit. This work is focused on the interrogation of sensor units based on resonance, denoted as resonant sensor units, in which the readout signals are the resonant frequency and, possibly, the quality factor. Specifically, capacitive and electromechanical piezoelectric resonator sensor units are considered. Two interrogation techniques, namely a frequency-domain technique and a time-domain technique, have been analyzed, that are theoretically independent of the coupling between the coils which, in turn, ensure that the sensor readings are not affected by the interrogation distance. However, it is shown that the unavoidable parasitic capacitance in parallel to the readout coil introduces, for both techniques, an undesired dependence of the readings on the interrogation distance. This effect is especially marked for capacitance sensor units. A compensation circuit is innovatively proposed to counteract the effects of the parasitic input capacitance, and advantageously obtain distance-independent readings in real operating conditions. Experimental tests on a coil-coupled capacitance sensor with resonance at 5.45 MHz have shown a deviation within 1.5 kHz, i.e., 300 ppm, for interrogation distances of up to 18 mm. For the same distance range, with a coil-coupled quartz crystal resonator with a mechanical resonant frequency of 4.432 MHz, variations of less than 1.8 Hz, i.e., 0.5 ppm, have been obtained.

8 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MRMichele Rosso
Michele Rosso
ANAlessandro Nastro
Alessandro Nastro
Marco BauMarco Bau
Marco Bau
Marco FerrariMarco Ferrari
Marco Ferrari
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari
Raffaele ArditoRaffaele Ardito
Raffaele Ardito
This work proposes a mono-axial piezoelectric energy harvester based on the innovative combination of magnetic plucking and indirect impacts, e.g., impacts happening on the package of the harvester. The harvester exploits a permanent magnet placed on a non-magnetic mass, free to move within a predefined bounded region located in front of a piezoelectric bimorph cantilever equipped with a magnet as the tip mass. When the harvester is subjected to a low-frequency external acceleration, the moving mass induces an abrupt deflection and release of the cantilever by means of magnetic coupling, followed by impacts of the same mass against the harvester package. The combined effect of magnetic plucking and indirect impacts induces a frequency up-conversion. A prototype has been designed, fabricated, fastened to the wrist of a person by means of a wristband, and experimentally tested for different motion levels. By setting the magnets in a repulsive configuration, after 50 s of consecutive impacts induced by shaking, an energy of 253.41 μJ has been stored: this value is seven times higher compared to the case of harvester subjected to indirect impacts only, i.e., without magnetic coupling. This confirms that the combination of magnetic plucking and indirect impacts triggers the effective scavenging of electrical energy even from low-frequency non-periodical mechanical movements, such as human motion, while preserving the reliability of piezoelectric components.

2 June 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Marco BauMarco Bau
Marco Bau
Marco FerrariMarco Ferrari
Marco Ferrari
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari
A technique for contactless electromagnetic interrogation of AT-cut quartz piezoelectric resonator sensors is proposed based on a primary coil electromagnetically air-coupled to a secondary coil connected to the electrodes of the resonator. The interrogation technique periodically switches between interleaved excitation and detection phases. During the excitation phase, the resonator is set into vibration by a driving voltage applied to the primary coil, whereas in the detection phase, the excitation signal is turned off and the transient decaying response of the resonator is sensed without contact by measuring the voltage induced back across the primary coil. This approach ensures that the readout frequency of the sensor signal is to a first order approximation independent of the interrogation distance between the primary and secondary coils. A detailed theoretical analysis of the interrogation principle based on a lumped-element equivalent circuit is presented. The analysis has been experimentally validated on a 4.432 MHz AT-cut quartz crystal resonator, demonstrating the accurate readout of the series resonant frequency and quality factor over an interrogation distance of up to 2 cm. As an application, the technique has been applied to the measurement of liquid microdroplets deposited on a 4.8 MHz AT-cut quartz crystal. More generally, the proposed technique can be exploited for the measurement of any physical or chemical quantities affecting the resonant response of quartz resonator sensors.