Adam Nawrocki

Dr. Adam Nawrocki


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2023 in Ecological Indicators
Verified
Journal Article
Open access
ANAdam Nawrocki
Adam Nawrocki
RPRobert Popek
Robert Popek
PSP. Sikorski
P. Sikorski
MWM. Wińska-Krysiak
M. Wińska-Krysiak
CZCh.Y. Zhu
Ch.Y. Zhu
APA. Przybysz
A. Przybysz

23 June 2023 in Environmental Science and Pollution Research
Verified
Journal Article
Open access
PDF file
APArkadiusz Przybysz
Arkadiusz Przybysz
ANAdam Nawrocki
Adam Nawrocki
EMEwa Mirzwa-Mróz
Ewa Mirzwa-Mróz
EPElżbieta Paduch-Cichał
Elżbieta Paduch-Cichał
KKKinga Kimic
Kinga Kimic
RPRobert Popek
Robert Popek
Particulate matter (PM) is one of the most important air pollutants, especially in urban areas. The efficiency of PM biofiltration by plants depends on the morphological features of the foliage. More PM is deposited on complex leaves, covered with thick wax layer, trichomes, epidermal glands, and convex venation. Very few literature reports suggest that also the presence of mycelium of nonparasitic and saprophytic fungi positively affects the accumulation of PM on the leaves. In this work, to our best knowledge, for the first time the effect of the mycelium of the parasitic powdery mildew on the efficiency of PM accumulation by urban greenery was studied. Uninfested and fungus-infested leaves of Acer negundo L., Malus domestica Borkh Quercus robur L., and Berberis vulgaris L. were harvested in July in the center of Warsaw city. The effect of powdery mildew infection on PM accumulation was species-specific. A higher amount of PM on leaves not infected with powdery mildew was found in M. domestica and Q. robur, while in A. negundo and B. vulgaris more PM was accumulated on leaves infected with fungus. All species (except A. negundo) accumulated more of the PM of 0.2–2.5-μm and 2.5–10-μm size fractions on leaves not infected with powdery mildew. One of the greatest consequences of the presence of powdery mildew mycelium on the foliage is most probably reduction of the direct involvement of waxes in PM accumulation and retention processes.

25 June 2025 in Land Degradation & Development
Verified
Journal Article
Closed access
Hanna MoniuszkoHanna Moniuszko
Hanna Moniuszko
Adrian ŁukowskiAdrian Łukowski
Adrian Łukowski
APArkadiusz Przybysz
Arkadiusz Przybysz
ANAdam Nawrocki
Adam Nawrocki
RPRobert Popek
Robert Popek

10 June 2026 in Atmosphere
Verified
Journal Article
Open access
PDF file
Simone PutzoluSimone Putzolu
Simone Putzolu
RITA BARALDIRITA BARALDI
RITA BARALDI
LNLuisa Neri
Luisa Neri
Alessandro ZaldeiAlessandro Zaldei
Alessandro Zaldei
CVCarolina Vagnoli
Carolina Vagnoli
CBCinzia De Benedictis
Cinzia De Benedictis
Students and workers spend much of their day in school and office environments, where poor indoor air quality (IAQ) can negatively affect health and comfort. Indoor vegetation is increasingly proposed as a low-cost nature-based solution (NBS) to improve IAQ. This study evaluated the effects of phytoremediation on IAQ and indoor microclimate in schools across different regions and educational levels, as well as in office environments, under real-world conditions. Several C3 plants (e.g., Chamaedorea, Schefflera, Ficus, Epipremnum, Yucca, and Spathiphyllum) were used, with crassulacean acid metabolism (CAM) plants (Sansevieria) included in selected settings. Temperature, relative humidity, CO2, PM2.5, and PM10 were continuously monitored using intercalibrated low-cost sensors in absence and presence of vegetation. A comparable plant configuration was implemented in offices to assess its effects on volatile organic compounds (VOC). Indoor greenery reduced particulate matter, especially PM10 (18–20%), and improved microclimatic conditions by lowering air temperature (1–2 °C) and increasing relative humidity (6–15%). However, CO2 reductions were limited and context-dependent. In the tested office environments, plant introduction was associated with reduced total VOC concentrations (25–50%). Overall, our results further support that indoor vegetation constitutes a robust, cost-effective nature-based solution (NBS) capable of complementing conventional ventilation systems in both school and office environments.

5 May 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
SPSimone Putzolu
Simone Putzolu
RITA BARALDIRITA BARALDI
RITA BARALDI
LNLuisa Neri
Luisa Neri
Alessandro ZaldeiAlessandro Zaldei
Alessandro Zaldei
CVCarolina Vagnoli
Carolina Vagnoli
CBCinzia De Benedictis
Cinzia De Benedictis
Students and workers spend much of their day in school and office environments, where poor indoor air quality (IAQ) can negatively affect health and comfort. Indoor vegetation is increasingly proposed as a low-cost Nature Based Solution (NBS) to improve IAQ. This study evaluated the effects of phytoremediation on IAQ and indoor microclimate in schools across different regions and educational levels, as well as in office environments, under real-world conditions. Several C3 plant species (e.g., Chamaedorea, Schefflera, Ficus, Epipremnum, Yucca and Spathiphyllum) were used, with Crassulacean Acid Metabolism (CAM) plants (Sansevieria) included in selected settings. Temperature, relative humidity, CO2, PM2.5, and PM10 were continuously monitored using intercalibrated low-cost sensors in absence and presence of vegetation. A comparable plant configuration was implemented in offices to assess effects on volatile organic compounds (VOC). Indoor greenery reduced particulate matters, especially PM10 (18-20%), and improved microclimatic condition by lowering air temperature (1-2 °C) and increasing relative humidity (6-15%). However, CO2 reductions were limited and context-dependent. In office environments, plant introduction was associated with reduced total VOC concentrations (25-50%) without evidence of biogenic VOC emissions. Overall, indoor vegetation represents a robust, low-cost NBS that can complement conventional ventilation systems in educational and occupational settings.

19 April 2023
Verified
Conference Paper
Closed access
ANAdam Nawrocki
Adam Nawrocki
RPRobert Popek
Robert Popek
APArkadiusz Przybysz
Arkadiusz Przybysz