Vicente Bruzzaniti

Dr. Vicente Bruzzaniti


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2022 in Cancers
Verified
Journal Article
Open access
PDF file
DVDiana Valente
Diana Valente
MGMaria Pia Gentileschi
Maria Pia Gentileschi
AGAntonino Guerrisi
Antonino Guerrisi
VBVicente Bruzzaniti
Vicente Bruzzaniti
AMAldo Morrone
Aldo Morrone
AVAlessandra Verdina
Alessandra Verdina
People exposed to ionizing radiation (IR) both for diagnostic and therapeutic purposes is constantly increasing. Since the use of IR involves a risk of harmful effects, such as the DNA DSB induction, an accurate determination of this induced DNA damage and a correct evaluation of the risk–benefit ratio in the clinical field are of key relevance. γH2AX (the phosphorylated form of the histone variant H2AX) is a very early marker of DSBs that can be induced both in physiological conditions, such as in the absence of specific external agents, and by external factors such as smoking, heat, background environmental radiation, and drugs. All these internal and external conditions result in a basal level of γH2AX which must be considered for the correct assessment of the DSBs after IR exposure. In this review we analyze the most common conditions that induce H2AX phosphorylation, including specific exogenous stimuli, cellular states, basic environmental factors, and lifestyles. Moreover, we discuss the most widely used methods for γH2AX determination and describe the principal applications of γH2AX scoring, paying particular attention to clinical studies. This knowledge will help us optimize the use of available methods in order to discern the specific γH2AX following IR-induced DSBs from the basal level of γH2AX in the cells.

27 November 2022 in Buildings
Verified
Journal Article
Open access
PDF file
FCFabio Lo Castro
Fabio Lo Castro
SISergio Iarossi
Sergio Iarossi
GBGiovanni Brambilla
Giovanni Brambilla
RMRaffaele Mariconte
Raffaele Mariconte
MDMaurizio Diano
Maurizio Diano
CGClaudia Giliberti
Claudia Giliberti
Noise in hospital wards adversely affects the physiological processes of both patients and staff and it is a potential risk for communication breakdowns and errors, causing discomfort and problems regarding the healing of patients, as well as stress, fatigue, and annoyance for staff. Several noise sources are present in the wards, such as HVAC systems, alarms, paging, speech, calls, diagnostic equipment, medical devices, and so forth. This paper describes two surveys carried out at an Italian hospital in Rome to investigate the noise in some wards and to collect self-reported assessments from staff about their working environments, even if such assessments were not required for occupational noise exposure evaluation. Self-reported staff evaluations of the working environment quality and the effects of noise on their performances should be investigated. For this purpose, in this study, questionnaires were designed and submitted to staff members. In addition, noise measurements were taken from short-, medium-, and long-term audio recordings processed to determine psychoacoustic parameters, e.g., loudness, sharpness, roughness, and fluctuation strength. Their applications in enclosed spaces can provide additional information on some features of the noise observed in hospital wards, which may influence the perceptions and relevant extra-auditory effects. Even though the results cannot be generalized, they encourage the development of a methodology for noise surveys in hospital wards, including noise measurements and “ad hoc” questionnaires to collect self-reported reactions from exposed staff members.

3 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SUSara Ungania
Sara Ungania
FSFrancesco Maria Solivetti
Francesco Maria Solivetti
MDMarco D’Arienzo
Marco D’Arienzo
FQFrancesco Quagliani
Francesco Quagliani
ISIsabella Sperduti
Isabella Sperduti
AGAntonino Guerrisi
Antonino Guerrisi
Over the last few decades, the need to reduce and optimize patient medical radiation exposure has prompted the introduction of novel reconstruction algorithms in computed tomography (CT). Against this backdrop, the present study aimed to assess whether reduced radiation dose CT images reconstructed with the new-generation adaptive statistical iterative reconstruction (ASiR-V) maintain the same image quality as that of routine image reconstruction. In addition, the optimization of image quality parameters for the ASiR-V algorithm (e.g., an optimal combination of blending percentage and noise index (NI)) was investigated. An abdominal reference phantom was imaged using the routine clinical protocol (fixed noise index of 18 and 40% ASiR reconstruction). Reduced radiation dose CT scans were performed with varying NI (22, 24, and 30) and using the ASiR-V reconstruction algorithm. Quantitative and qualitative analyses of image noise, contrast, and resolution were performed against NI and reconstruction blending percentages. Our results confirm the ability of the ASiR-V algorithm to provide images of high diagnostic quality while reducing the patient dose. All the parameters were improved in ASiR-V images as compared to ASiR. Both quantitative and qualitative analyses showed that the best agreement was obtained for the images reconstructed using ASiR-V with NI24 and a high percentage of blending (70–100%). This preliminary study results show that ASiR-V allows for a significant reduction in patient dose (about 40%) while maintaining a good overall image quality when appropriate NI (i.e., 24) is used.

Verified
Journal Article
Open access
PDF file
DVDavide Valente
Davide Valente
MGMaria Pia Gentileschi
Maria Pia Gentileschi
AVAlessandro Valenti
Alessandro Valenti
MBMassimo Burgio
Massimo Burgio
SSSilvia Soddu
Silvia Soddu
AVAlessandra Verdina
Alessandra Verdina
Recurrent computed tomography (CT) examination has become a common diagnostic procedure for several diseases and injuries. Though each singular CT scan exposes individuals at low doses of low linear energy transfer (LET) radiation, the cumulative dose received from recurrent CT scans poses an increasing concern for potential health risks. Here, we evaluated the biological effects of recurrent CT scans on the DNA damage response (DDR) in human fibroblasts and retinal pigment epithelial cells maintained in culture for five months and subjected to four CT scans, one every four weeks. DDR kinetics and eventual accumulation of persistent-radiation-induced foci (P-RIF) were assessed by combined immunofluorescence for γH2AX and 53BP1, i.e., γH2AX/53BP1 foci. We found that CT scan repetitions significantly increased both the number and size of γH2AX/53BP1 foci. In particular, after the third CT scan, we observed the appearance of giant foci that might result from the overlapping of individual small foci and that do not associate with irreversible growth arrest, as shown by DNA replication in the foci-carrying cells. Whether these giant foci represent coalescence of unrepaired DNA damage as reported following single exposition to high doses of high LET radiation is still unclear. However, morphologically, these giant foci resemble the recently described compartmentalization of damaged DNA that should facilitate the repair of DNA double-strand breaks but also increase the risk of chromosomal translocations. Overall, these results indicate that for a correct evaluation of the damage following recurrent CT examinations, it is necessary to consider the size and composition of the foci in addition to their number.

6 October 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SUSara Ungania
Sara Ungania
MDMarco D’Arienzo
Marco D’Arienzo
SNSandro Nocentini
Sandro Nocentini
MDMarco D'Andrea
Marco D'Andrea
VBVicente Bruzzaniti
Vicente Bruzzaniti
LSLidia Strigari
Lidia Strigari
Radioembolization (RE) with 90Y-microspheres has gained widespread acceptance as a safe and effective technique for treating liver malignancies. Accurate quantification in RE is a key step in treatment planning optimization and is becoming a pressing issue in light of the Directive 2013/59/EURATOM. The aim of this study was to develop a SPECT/CT imaging protocol for quantitative imaging optimization in RE based on cutting edge imaging technology (Symbia IntevoTM system provided with the innovative xSPECT software) and a novel anthropomorphic 3D-printed phantom. In the present study, 99mTc-labeled macroaggregated albumin was used as a surrogate radiopharmaceutical for treatment planning. Gamma camera calibration factors and recovery coefficients were determined performing preliminary SPECT/CT acquisitions of a point source, a cylindrical homogeneous phantom and the NEMA/IEC phantom. Data reconstruction was performed using the built-in xSPECT package, using both the Ordered Subset Expectation–Maximization (OSEM) and the Ordered Subset Conjugated Gradient (OSCG) algorithm. Specific regions of interest (ROIs) were drawn on the MIM 6.1.7 system according to the physical volume. The quantification procedure was validated using the anthropomorphic phantom provided with a fillable liver section and spheres of different diameters (20 mm, 40 mm and a 40 mm spherical shell). The measured activity concentration in all geometries is consistent within 4%, demonstrating that the xSPECT software permit an absolute quantification in anthropomorphic geometry largely within the 10% recommended from the manufacturer. Caution is advised in the presence of spherical objects with a necrotic core, as underestimations in the order of 20% were obtained.