Jingmei Zhang

Dr. Jingmei Zhang

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2021 in Anesthesiology
Verified
Journal Article
Open access
PDF file
DDDaosong Dong
Daosong Dong
MZMingfang Zhao
Mingfang Zhao
JZJingmei Zhang
Jingmei Zhang
MHMing Huang
Ming Huang
YWYanwei Wang
Yanwei Wang
TSTao Song
Tao Song
Background: Neurolytic splanchnic nerve block is used to manage pancreatic cancer pain. However, its impact on survival and quality of life remains controversial. The authors’ primary hypothesis was that pain relief would be better with a nerve block. Secondarily, they hypothesized that analgesic use, survival, and quality of life might be affected. Methods: This randomized, double-blind, parallel-armed trial was conducted in five Chinese centers. Eligible patients suffering from moderate to severe pain conditions were randomly assigned to receive splanchnic nerve block with either absolute alcohol (neurolysis) or normal saline (control). The primary outcome was pain relief measured on a visual analogue scale. Opioid consumption, survival, quality of life, and adverse effects were also documented. Analgesics were managed using a protocol common to all centers. Patients were followed up for 8 months or until death. Results: Ninety-six patients (48 for each group) were included in the analysis. Pain relief with neurolysis was greater for the first 3 months (largest at the first month; mean difference, 0.7 [95% CI, 0.3 to 1.0]; adjusted P < 0.001) compared with placebo injection. Opioid consumption with neurolysis was lower for the first 5 months (largest at the first month; mean difference, 95.8 [95% CI, 67.4 to 124.1]; adjusted P < 0.001) compared with placebo injection. There was a significant difference in survival (hazard ratio, 1.56 [95% CI, 1.03 to 2.35]; P = 0.036) between groups. A significant reduction in survival in neurolysis was found for stage IV patients (hazard ratio, 1.94 [95% CI, 1.29 to 2.93]; P = 0.001), but not for stage III patients (hazard ratio, 1.08 [95% CI, 0.59 to 1.97]; P = 0.809). No differences in quality of life were observed. Conclusions: Neurolytic splanchnic nerve block appears to be an effective option for controlling pain and reducing opioid requirements in patients with unresectable pancreatic cancer. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:

10 June 2013 in Journal of Systems Engineering and Electronics
Verified
Journal Article
Closed access
YHYiqing Huang
Yiqing Huang
CSChangyin Sun
Changyin Sun
CQChengshan Qian
Chengshan Qian
JZJingmei Zhang
Jingmei Zhang
LWLi Wang
Li Wang
A novel gain-scheduled switching control method for the longitudinal motion of a flexible air-breathing hypersonic vehicle (FAHV) is proposed. Firstly, velocity and altitude are selected as scheduling variables, a polytopic linear parameter varying (LPV) model is developed to represent the complex nonlinear longitudinal dynamics of the FAHV. Secondly, based on the obtained polytopic LPV model, the flight envelope is divided into four smaller subregions, and four gain-scheduled controllers are designed for these parameter subregions. Then, by the defined switching characteristic function, these gain-scheduled controllers are switched in order to guarantee the closed-loop FAHV system to be asymptotically stable and satisfy a given tracking error performance criterion. The condition of gain-scheduled switching controller synthesis is given in terms of linear matrix inequalities (LMIs) which can be easily solved by using standard software packages. Finally, simulation results show the effectiveness of the presented method.

14 June 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LPLei Pan
Lei Pan
JZJunru Zhang
Junru Zhang
JZJingmei Zhang
Jingmei Zhang
YPYi Pang
Yi Pang
BWBeibei Wang
Beibei Wang
DXDongxing Xu
Dongxing Xu
Nine-switch converter (NSC) has been presented as a dual-output converter with common frequency (CF) or different frequency (DF) operation modes. This paper proposes a novel space-vector modulation (SVM) method for the NSC that supports both the CF and DF modes. This method is based on the simplification of the space-vector diagram of NSC into that of six-switch converter, and the SVM method for NSC can be done like conventional SSC. The proposed voltage vector selection method without using common logical xor operation and the calculation method for dwelling times of voltage vectors are described in detail. In addition, the modulation indices for two ac terminals of NSC have been analyzed deeply, and the derived fitting equations can guide engineering application. The performance of the proposed SVM is verified by the simulation and experimental results, and the low total harmonic distortions and harmonic components for phase currents prove the effectiveness of the proposed method.

16 March 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JZJingmei Zhang
Jingmei Zhang
YPYi Pang
Yi Pang
KWKai Wang
Kai Wang
DXDongxing Xu
Dongxing Xu
LPLei Pan
Lei Pan
In this paper, the equivalent mechanism between Nine-Switch Converter (NSC) and the two Six-Switch Converters (SSCs) is explained in detail. In order to achieve the decoupling of the Upper and Lower AC terminals, the concept of Virtual-Leg is proposed and the decoupling model of NSC is established based on Virtual-Legs. In this model, the NSC is equivalent to dual constrained SSCs. Continually, the Space vector modulation (SVM) method of NSC is proposed based on dual constrained SSCs modulation for both Common Frequency (CF) and Different Frequency (DF) modes. In the proposed modulation method, the concept of Space Vector Distance Function (SVDF) is proposed. SVDF represents the actual switching times between any two actual working states of NSC. The closer distance between the two actual states is, the smaller actual switching loss will be. Using the modulation method, the NSC can realize the independent control of two sets of three-phase AC voltage and achieve the same control performance as the dual SSCs. The validity of the proposed converter is verified through simulations and experiments.

9 December 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KWKai Wang
Kai Wang
JZJingmei Zhang
Jingmei Zhang
YPYi Pang
Yi Pang
DXDongxing Xu
Dongxing Xu
LPLei Pan
Lei Pan
This paper proposes a doubly fed induction generator (DFIG) wind energy conversion system (WECS) based on nine-switch converter (NSC). In this paper, a new concept of Virtual-Leg is proposed, and the equivalent mechanism between the NSC and the dual six-switch converter is first proposed in this research. Furthermore, a mathematical model of the NSC based on the unipolar binary logic switching function is established. In order to simplify the mathematical model of the NSC-based DFIG-WECS, the parameters mapping relationship between the NSC with loads and the NSC-based DFIG-WECS under dq coordinate system is given. Meanwhile, the Adaptive Resonant PI (AR-PI) current controller based on the resonant controller, the PI controller, and the adaptive genetic algorithm is applied for the DFIG wind generation system. As a result, harmonic current content, overshoot, and dynamic response speed of the NSC-based DFIG-WECS have been significantly improved. Finally, the simulations and experimental results verify the validity and reliability of the proposed mathematical model and control algorithm.

8 March 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
LPLei Pan
Lei Pan
JZJunru Zhang
Junru Zhang
JZJingmei Zhang
Jingmei Zhang
KWKai Wang
Kai Wang
YPYi Pang
Yi Pang
BWBeibei Wang
Beibei Wang
A new topology of a three-level neutral-point-clamped fifteen-switch inverter is proposed. The FSI topology consists of three legs, of which each consists of five switches and two diodes. Afifteen-switch invertercan independently drive two three-phase loads. In addition, a new space vector modulation method suitable for thefifteen-switch inverter to drive two three-phase loads is described in detail; moreover, the space vector modulation method is suitable for both common-frequency and difference-frequency working modes of an FSI. The application on independent control of two three-phase loads for an FSI is verified well by simulations and experiments.