Ji-yeon Han

Dr. Ji-yeon Han

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
DKD. Kim
D. Kim
YHY.J. Heo
Y.J. Heo
HJH.W. Jeong
H.W. Jeong
JBJ.W. Baek
J.W. Baek
JHJi-yeon Han
Ji-yeon Han
HBH.J. Baek
H.J. Baek
BACKGROUND AND PURPOSE: Contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolution (SPACE) with the delay alternating with nutation for tailored excitation (DANTE) pulse could suppress the blood flow signal and provide a higher contrast-to-noise ratio of enhancing lesion-to-brain parenchyma than the MPRAGE sequence. The purpose of our study was to evaluate the usefulness of SPACE with DANTE compared with MPRAGE for detecting brain metastases. MATERIALS AND METHODS: Seventy-one patients who underwent contrast-enhanced SPACE with DANTE and MPRAGE sequences and who were suspected of having metastatic lesions were included. Two neuroradiologists determined the number of enhancing lesions, and diagnostic performance was evaluated using figure of merit, sensitivity, positive predictive value, interobserver agreement, and reading time. Contrast-to-noise ratiolesion/parenchyma and contrast-to-noise ratiowhite matter/gray matter were also assessed. RESULTS: SPACE with DANTE (observer one, 328; observer two, 324) revealed significantly more small (<5 mm) enhancing lesions than MPRAGE (observer one, 175; observer two, 150) (P < 0.001 for observer 1, P ≤ .0001 for observer 2). Furthermore, SPACE with DANTE showed significantly higher figure of merit and sensitivity and shorter reading time than MPRAGE for both observers. The mean contrast-to-noise ratiolesion/parenchyma of SPACE with DANTE (52.3 ± 43.1) was significantly higher than that of MPRAGE (17.5 ± 19.3) (P ≤ .0001), but the mean contrast-to-noise ratiowhite matter/gray matter of SPACE with DANTE (−0.65 ± 1.39) was significantly lower than that of MPRAGE (3.08 ± 1.39) (P ≤ .0001). CONCLUSIONS: Compared with MPRAGE, SPACE with DANTE significantly improves the detection of brain metastases.

1 January 2021 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
HCHyejeung Choo
Hyejeung Choo
SLSun Joo Lee
Sun Joo Lee
DKDong Wook Kim
Dong Wook Kim
YLYoo Jin Lee
Yoo Jin Lee
JBJin Wook Baek
Jin Wook Baek
YHYoung Jin Heo
Young Jin Heo
Choo HJ, et al. Korean J Radiol. 2021 May;22:e70. https://doi.org/10.3348/kjr.2020.0548

27 December 2022 in Acta Radiologica
Verified
Journal Article
Closed access
DKDasom Kim
Dasom Kim
JHJi-yeon Han
Ji-yeon Han
JBJin Wook Baek
Jin Wook Baek
HLHo Young Lee
Ho Young Lee
HCHwa Jin Cho
Hwa Jin Cho
GSGi Won Shin
Gi Won Shin
Background: Computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) is highly affected by respiratory motion; however, respiratory motion of target nodule during the PTNB and its effect on CT-guided lung biopsy have not been studied. Purpose: To investigate the effect of the respiratory motion of pulmonary nodules on CT-guided PTNB. Material and Methods: We retrospectively reviewed the procedural CT scans of 426 pulmonary nodules that underwent PTNB during quiet breathing. Maximal and average respiratory motions were measured using the difference of table position of the targeted nodule between multiple procedural scans. Diagnostic performance, complications, and technical factors of PTNB in nodules with large motion (maximal motion >1 cm) were compared with those in nodules with small motion (≤1 cm). Results: The mean maximal and average respiratory motions between tidal volume breathing were 5.4 ± 4.4 and 2.7 ± 2.6 mm, respectively. Sensitivity and accuracy were 93.1% and 96.1% in nodules with large motion, compared with 94.7% and 95.9% in nodules with small motion, respectively. Respiratory targeting ( P < 0.001), needle modulation ( P < 0.001), motion artifact of target ( P < 0.001), target disappearance from scans ( P < 0.001), and number of performed CT scans ( P < 0.001) were significantly higher in the large motion group, with no significant difference in radiation dose and complications between the groups. Conclusion: The respiratory motion of pulmonary nodules during CT-guided PTNB may cause technical difficulties but does not affect diagnostic performance nor complications associated with PTNB.

1 November 2024 in Neurointervention
Verified
Journal Article
Open access
PDF file
JBJinwook Baek
Jinwook Baek
HJHae Woong Jeong
Hae Woong Jeong
JHJi-yeon Han
Ji-yeon Han
YHYoung Jin Heo
Young Jin Heo
SYSooyoung Yun
Sooyoung Yun
SKSung Tae Kim
Sung Tae Kim
Purpose: In this study, we determined whether there were significant differences in procedure time, radiation dose, fluoroscopy time, and total contrast media dose when unruptured wideneck bifurcation aneurysms (WNBAs) were treated with the Woven EndoBridge (WEB) device and stent-assisted coil (SAC) embolization.Materials and Methods: The WEB device and SAC embolization (14:17) were used to treat 31 cases of internal carotid artery bifurcation, anterior communicating artery, middle cerebral artery bifurcation, and basilar bifurcation aneurysms between August 2021 and December 2022. The procedure time, radiation dose, fluoroscopy time, and total contrast medium dose between the 2 treatment groups were compared and analyzed. In the WEB device group, the results between operators were compared, and the follow-up radiologic outcomes were investigated.Results: The procedure and fluoroscopy times were significantly shorter in the WEB device group. Radiation and total contrast media dose were also significantly smaller in the WEB device, but there was no significant difference in results between operators. The follow-up radiological outcome showed adequate occlusion in 83.3% (10/12) of cases.Conclusion: The WEB device can be used as an alternative treatment method among the available endovascular treatment methods for WNBAs to reduce radiation exposure and the dose of contrast media when used adequately with appropriate indications.

1 September 2022 in Current Medical Imaging
Verified
Journal Article
Closed access
PDF file
JPJinyoung Park
Jinyoung Park
GSGeojeong Seo
Geojeong Seo
ELEunjoo Lee
Eunjoo Lee
JHJi-yeon Han
Ji-yeon Han
DKDasom Kim
Dasom Kim
HPHa Young Park
Ha Young Park
Introduction: Angiolipoleiomyoma (ALLM) is a rare hamartomatous tumor of mesenchymal origin composed of smooth muscle, mature adipose tissue, and blood vessels in various proportions. Because of its histologic similarity to renal angiomyolipoma (AML), it is also called uterine angiomyolipoma. Preoperative diagnosis of uterine ALLM is very challenging due to its uncommon incidence and absence of established characteristic imaging findings. Case description: A 50-year-old multiparous female patient visited our institution for gynecologic screening. Transvaginal sonography (TVS), Abdominopelvic computed tomography (CT), and pelvic magnetic resonance imaging (MRI) revealed large well-defined masses involving the posterior uterine wall with rectal indentation. The patient underwent a total abdominal hysterectomy for this tumor and the histopathological diagnosis was uterine ALLM. Conclusion: This report would contribute to understanding and establishing the radiologic findings of the uterine ALLM. Considering the benign characteristics and favorable prognosis of this rare tumor, familiarity with its imaging findings by radiologists will guide clinicians in better patient management and prevention of unnecessary radical surgery.

1 January 2024 in Journal of the Korean Society of Radiology
Verified
Journal Article
Open access
PDF file
JPJi Young Park
Ji Young Park
JHJi-yeon Han
Ji-yeon Han
SCSeok Jin Choi
Seok Jin Choi
JBJin Wook Baek
Jin Wook Baek
SYSu Young Yun
Su Young Yun
SHSungMin Hong
SungMin Hong
박지영, et al. J Korean Soc Radiol. 2024 Feb;85:e29. https://doi.org/10.3348/jksr.2023.0093