Ki-Hwan Kim

Dr. Ki-Hwan Kim


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2022 in Cancers
Verified
Journal Article
Open access
PDF file
MKMyeongsoo Kim
Myeongsoo Kim
UHUi-Jung Hwang
Ui-Jung Hwang
KPKyeongyun Park
Kyeongyun Park
DKDohyeon Kim
Dohyeon Kim
HKHaksoo Kim
Haksoo Kim
임L임영경 Young Kyung Lim
임영경 Young Kyung Lim
The feasibility of proton minibeam radiation therapy (pMBRT) using a multislit collimator (MSC) and a scattering device was evaluated for clinical use at a clinical proton therapy facility. We fabricated, through Monte Carlo (MC) simulations, not only an MSC with a high peak-to-valley dose ratio (PVDR) at the entrance of the proton beam, to prevent radiation toxicity, but also a scattering device to modulate the PVDR in depth. The slit width and center-to-center distance of the diverging MSC were 2.5 mm and 5.0 mm at the large end, respectively, and its thickness and available field size were 100 mm and 76 × 77.5 mm2, respectively. Spatially fractionated dose distributions were measured at various depths using radiochromic EBT3 films and also tested on bacterial cells. MC simulation showed that the thicker the MSC, the higher the PVDR at the phantom surface. Dosimetric evaluations showed that lateral dose profiles varied according to the scatterer’s thickness, and the depths satisfying PVDR = 1.1 moved toward the surface as their thickness increased. The response of the bacterial cells to the proton minibeams’ depth was also established, in a manner similar to the dosimetric pattern. Conclusively, these results strongly suggest that pMBRT can be implemented in clinical centers by using MSC and scatterers.

1 July 2023 in Journal of Instrumentation
Verified
Journal Article
Closed access
SYS.W. Yang
S.W. Yang
SPS.K. Park
S.K. Park
CMC.W. Moon
C.W. Moon
KKKi-Hwan Kim
Ki-Hwan Kim
In brachytherapy, quality assurance (QA) is a prerequisite to minimize the dose irradiation to the healthy tissues in patients during treatment, as it evaluates the accuracy of the dose applied to the patients as well as the accuracy of the position of the irradiation. Therefore, a strong emphasis has been placed on brachytherapy QA in clinical practice. This study assessed the suitability of a CsPbI3 dosimeter for the brachytherapy QA system. To verify the reliability of the unit cell sensor fabricated with CsPbI3, the electrical parameters were evaluated, after which the position dependence of the sensor was analyzed. A high level of reliability (R 2 > 0.99) and reproducibility (relative standard deviation < 1.5%) were observed. The maximal value measured at the isocenter of the sensor as the distance of the dosimeter from the irradiation source was gradually decreased. When the optimal angle was assessed, the variation was as high as 5.01 nC depending on the form of the 192Ir source. Therefore, the CsPbI3 dosimeter fabricated in this study is a suitable substitute for the conventional QA dosimeter.

22 February 2021 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
NSNazia Neelam Shehzadi
Nazia Neelam Shehzadi
CYChul-Young Yi
Chul-Young Yi
KKKi-Hwan Kim
Ki-Hwan Kim
JJJaeuk Jang
Jaeuk Jang
UHUi-Jung Hwang
Ui-Jung Hwang
YSYoung Min Seong
Young Min Seong

1 April 2024 in Journal of Instrumentation
Verified
Journal Article
Closed access
SYS.W. Yang
S.W. Yang
SPS.K. Park
S.K. Park
KKKi-Hwan Kim
Ki-Hwan Kim
Volumetric modulated arc therapy represents the latest technology in radiotherapy. It involves continuous modification of the multi-leaf collimator spatial distribution, dose rate, and gantry rotational speed, necessitating a dosimeter with high spatial resolution and exceptional sensitivity per unit volume. In particular, cesium-based inorganic perovskites have been studied for various applications, spanning from photoconductor solar cells to radiation detectors. These perovskites are renowned for their outstanding attributes, including thermal stability, inorganic stability, and light absorption capacity. Despite such advantageous characteristics, CsPbI3 materials have only been investigated in radiodiagnostics, with limited exploration in radiotherapy. To address this gap, this study verified the viability of CsPbI3 materials, note for their outstanding radiation detection efficiency, as dosimeters capable of measuring the radiation detection performance for radiotherapy devices. The reproducibility, linearity, and percent depth dose (PDD) were evaluated under the application of photon and electron beams in linear accelerators. The reproducibility assessment revealed impressive results, with the relative standard deviation registering at 0.53%, 0.32%, and 0.38% under electron beam energies of 6, 9, and 12 MeV and 0.45%, and 0.89% under photon beam energies of 6 and 15 MV. Moreover, the linearity test revealed an R 2 value of 0.9999, indicating high linearity, at 6, 9, and 12 MeV and at 6 and 15 MV. The PDD graphs drawn for the CsPbI3 dosimeter fabricated in this study showed that the D max points were consistent. The novel CsPbI3 dosimeter demonstrated a level of detection performance that satisfied all criteria; reproducibility, linearity, and PDD. The results collectively indicated that the CsPbI3 dosimeter can be used for dosimeters in radiotherapy devices.

31 December 2022 in Progress in Medical Physics
Verified
Journal Article
Open access
PDF file
UHUi-Jung Hwang
Ui-Jung Hwang
BMByong Jun Min
Byong Jun Min
MKMeyoung Kim
Meyoung Kim
KKKi-Hwan Kim
Ki-Hwan Kim
Ui-Jung Hwang, Byong Jun Min, Meyoung Kim, Ki-Hwan Kim. Progress in Medical Physics 2022;33:37-52. https://doi.org/10.14316/pmp.2022.33.4.37

28 April 2018 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
UHUi-Jung Hwang
Ui-Jung Hwang
DSDongho Shin
Dongho Shin
SLSe Byeong Lee
Se Byeong Lee
YLYoung Kyung Lim
Young Kyung Lim
JJJong Hwi Jeong
Jong Hwi Jeong
KKKi-Hwan Kim
Ki-Hwan Kim
To apply a scintillating fiber dosimetry system to measure the range of a proton therapy beam, a new method was proposed to correct for the quenching effect on measuring an spread out Bragg peak (SOBP) proton beam whose range is modulated by a range modulator wheel. The scintillating fiber dosimetry system was composed of a plastic scintillating fiber (BCF-12), optical fiber (SH 2001), photo multiplier tube (H7546), and data acquisition system (PXI6221 and SCC68). The proton beam was generated by a cyclotron (Proteus-235) in the National Cancer Center in Korea. It operated in the double-scattering mode and the spread out of the Bragg peak was achieved by a spinning range modulation wheel. Bragg peak beams and SOBP beams of various ranges were measured, corrected, and compared to the ion chamber data. For the Bragg peak beam, quenching equation was used to correct the quenching effect. On the proposed process of correcting SOBP beams, the measured data using a scintillating fiber were separated by the Bragg peaks that the SOBP beam contained, and then recomposed again to reconstruct an SOBP after correcting for each Bragg peak. The measured depth-dose curve for the single Bragg peak beam was well corrected by using a simple quenching equation. Correction for SOBP beam was conducted with a newly proposed method. The corrected SOBP signal was in accordance with the results measured with an ion chamber. We propose a new method to correct for the SOBP beam from the quenching effect in a scintillating fiber dosimetry system. This method can be applied to other scintillator dosimetry for radiation beams in which the quenching effect is shown in the scintillator.