Seung-Woo Yang

Seung-Woo Yang

Auto-generated profile, based on publicly available information

Seung-Woo Yang

Radiation Therapy Technology and Standards, Korea Institute of Radiological and Medical Sciences, Seoul, Korea

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2024 in Journal of Instrumentation
Verified
Journal Article
Closed access
SYS.W. Yang
S.W. Yang
SPS.K. Park
S.K. Park
KKKi-Hwan Kim
Ki-Hwan Kim
Volumetric modulated arc therapy represents the latest technology in radiotherapy. It involves continuous modification of the multi-leaf collimator spatial distribution, dose rate, and gantry rotational speed, necessitating a dosimeter with high spatial resolution and exceptional sensitivity per unit volume. In particular, cesium-based inorganic perovskites have been studied for various applications, spanning from photoconductor solar cells to radiation detectors. These perovskites are renowned for their outstanding attributes, including thermal stability, inorganic stability, and light absorption capacity. Despite such advantageous characteristics, CsPbI3 materials have only been investigated in radiodiagnostics, with limited exploration in radiotherapy. To address this gap, this study verified the viability of CsPbI3 materials, note for their outstanding radiation detection efficiency, as dosimeters capable of measuring the radiation detection performance for radiotherapy devices. The reproducibility, linearity, and percent depth dose (PDD) were evaluated under the application of photon and electron beams in linear accelerators. The reproducibility assessment revealed impressive results, with the relative standard deviation registering at 0.53%, 0.32%, and 0.38% under electron beam energies of 6, 9, and 12 MeV and 0.45%, and 0.89% under photon beam energies of 6 and 15 MV. Moreover, the linearity test revealed an R 2 value of 0.9999, indicating high linearity, at 6, 9, and 12 MeV and at 6 and 15 MV. The PDD graphs drawn for the CsPbI3 dosimeter fabricated in this study showed that the D max points were consistent. The novel CsPbI3 dosimeter demonstrated a level of detection performance that satisfied all criteria; reproducibility, linearity, and PDD. The results collectively indicated that the CsPbI3 dosimeter can be used for dosimeters in radiotherapy devices.

1 March 2024 in Journal of Instrumentation
Verified
Journal Article
Closed access
SYSeung-Woo Yang
Seung-Woo Yang
YSYo-Han Shin
Yo-Han Shin
JJJae-Hoon Jung
Jae-Hoon Jung
HCHeung-Lae Cho
Heung-Lae Cho
SPSung-Kwang Park
Sung-Kwang Park
Quality assurance (QA) of electron beams must be performed regularly to ensure accurate radiation therapy. Therefore, a QA dosimeter for electron beams is required for accurate electron beam QA measurement. In this study, the electron beam detection performance of CsPbBr3 material was measured. And it was evaluated whether it could be applied as a QA dosimeter for electron beams. To evaluate feasibility, reproducibility, linearity, and PDD were measured, and evaluated at 6 MeV, 9 MeV, and 12 MeV energies of the linear accelerator. The reproducibility evaluation results showed relative standard deviations of 1.06% at 6 MeV, 1.39% at 9 MeV, and 1.49% at 12 MeV. Linearity result evaluation, the coefficient of determination R2 was presented as 0.9996, 0.9994, and 0.9992 at energies of 6, 9, and 12 MeV, respectively. When PDD was measured using the manufactured dosimeter, Dmax points for each energy band of 6, 9, and 12 MeV were shown. The CsPbBr3 relative dosimeter produced in this study shows detection performance that satisfies the evaluation criteria of reproducibility, linearity, and PDD. These results mean that the CsPbBr3 dosimeter is feasible as a QA dosimeter dedicated to electron beams.

1 September 2024 in Journal of Instrumentation
Verified
Journal Article
Closed access
SYS.W. Yang
S.W. Yang
YSY.H. Shin
Y.H. Shin
SPS.K. Park
S.K. Park
Methylammonium lead iodide (MAPbI3) perovskite is a well-known organic-inorganic lead halide perovskite that has gained much attention because of its advantages such as a high absorption coefficient for radiation absorption, high carrier mobility, high defect tolerance, and outstanding solution processability. In this study, we aimed to fabricate radiation detection sensors and relative dosimeters using MAPbI3 and evaluate their applicability as quality assurance (QA) equipment for brachytherapy. MAPbI3 film dosimeters of various thicknesses were fabricated, and their responses to Iridium-192 source were evaluated to determine the suitable thickness for radiation detection sensors. Additionally, the ability to use the fabricated QA relative dosimeter for brachytherapy was determined based on the results of reproducibility and linearity evaluations. The evaluation of the reproducibility of the fabricated MAPbI3 radiation detection sensors with thicknesses of 150 and 225 μm showed standard deviations of 0.51% and 1.14%, respectively, which met the evaluation criterion of ≤ 1.5%. The evaluation of linearity indicated R2 values of 0.9999 and 0.9998, respectively, which met the criterion of ≥ 0.9990. The results clearly demonstrated that the MAPbI3 dosimeter fabricated during this study may be used as a QA relative dosimeter for brachytherapy.

1 September 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
YSYohan Shin
Yohan Shin
YYYungi Yeom
Yungi Yeom
SYSeungwoo Yang
Seungwoo Yang
MHMoojae Han
Moojae Han
HCHeunglae Cho
Heunglae Cho
SPSungkwang Park
Sungkwang Park
CsPbI3, a perovskite material, has garnered significant attention in solar cell research owing to its unique crystal structure and optimal band-gap energy. Recently, CsPbI3 has also been explored for use in dosimeters in the radiotherapeutic field. This study analyzes the reaction characteristics of CsPbI3 to the 192Ir radioisotope, focusing on how the material thickness influences performance. The aim of this study is to identify the optimal thickness and measurement conditions of CsPbI3. Before fabricating the sensor for evaluation, CsPbI3 is synthesized using CsI and PbI2 precursors. Operational voltage factors are determined by analyzing the dark current and photocurrent from four unit-cell sensors with CsPbI3 thicknesses ranging from 100 to 250 μm. These voltage factors are then applied to evaluate the linearity and repeatability in each sensor. The results of the operational voltage factor tests indicate that +2 V/μm provides optimal electrical stability and measurement efficiency. All sensors demonstrate a high linearity (R 2 > 0.9990) and satisfy the repeatability criterion (CV < 1.5%), although thicker sensors exhibit higher CV values. Notably, the 250 μm sensor has a margin of error of < 0.1% for repeatability, indicating potential challenges in maintaining performance under varying environmental conditions. Further analysis reveals a positive correlation between sensor thickness and sensitivity. Based on these findings, a +400 V operational voltage is recommended for application to a 200 μm thick sensor as the optimal condition for stable and efficient measurements with CsPbI3-based sensors. Future studies involving various radiotherapy equipment and diverse types and energies of radiation are necessary to establish comprehensive optimized conditions for radiotherapeutic quality assurance.

1 November 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
YSYohan Shin
Yohan Shin
YYYungi Yeom
Yungi Yeom
SYSeungwoo Yang
Seungwoo Yang
MHMoojae Han
Moojae Han
JKJinyoung Kim
Jinyoung Kim
SPSungkwang Park
Sungkwang Park
CsPb-based perovskites are promising materials for solar cells because of their low unit production cost and high efficiency. Among them, halide materials have also attracted research attention in the field of radiation therapy. In this study, we analyzed the characteristics of CsPbI 2 Cl — a CsPb-based halide perovskite — under high-energy radiation at levels equivalent to those used in clinical therapy to evaluate its feasibility for quality assurance (QA) in radiation therapy. We fabricated a CsPbI 2 Cl-based sensor after synthesizing CsPbI 2 Cl from its precursors, i.e., CsCl and PbI 2 , and evaluated the linearity, repeatability, dose-rate dependence, and percent depth dose (PDD) under irradiation with energy of 6 and 15 MV. All the evaluated parameters except for the PDD met the criteria ( R 2 > 0.99900 and CV< 1.5%). However, PDD 20/10 , which is one of the criteria for PDD, exhibited errors of 6.34% and 3.74% for 6 and 15 MV, respectively, compared with the ionization chamber, which provides the reference value for actual QA. This may be due to the unique response characteristics of semiconductor-based dosimeters and the high atomic number of the components of CsPbI 2 Cl. According to the results, the CsPbI 2 Cl-based sensor developed in this study was evaluated for its reliability and stability against high-energy radiation, but it still needs to be improved for depth-dose measurement. With follow-up studies for improving the sensor structure and considering additional variables, we expect that this sensor can be employed as a dosimeter for clinical QA.