X-ray phase imaging provides higher sensitivity to polymer materials made of light elements than the sensitivity provided by conventional X-ray transmission imaging that relies on absorption contrast. High-speed X-ray phase imaging has recently been studied using pink-beam synchrotron radiation and a Talbot interferometer to enable dynamic observation. In this study, we adopted high-speed X-ray phase imaging for the inner visualization of polymer materials under laser engraving. A sequence of phase-stepping-based phase imaging with a temporal resolution of 5 ms was established by synchronizing an X-ray detector with the linear motions of a grating and a sample. The laser and X-ray paths were aligned orthogonally, and the engraving region was observed from the material surface in the depth direction, in which ablation followed by bubble formation with a certain time delay was demonstrated.
18 February 2026 in Journal of Synchrotron Radiation
We report on the coherence evaluation of the beamline BL09W at NanoTerasu (Tohoku University, Japan) and demonstrate X-ray multi-contrast imaging using an X-ray Talbot interferometer. Fringe visibility was measured in both the horizontal and vertical directions and analyzed to estimate the effective source size of the X-ray beam. The estimated source size in the horizontal direction was consistent with the design specification, confirming the validity of the measurements. In the vertical direction, the high visibility, exceeding 70%, indicates the remarkably high spatial coherence of the source. Multi-contrast computed tomography was successfully performed, simultaneously reconstructing absorption, phase and small-angle scattering contrasts. These results establish BL09W as a versatile beamline for coherence-based X-ray imaging.
Acoustic cavitation, also called ultrasonic cavitation, can produce aggressive intensity leading to cavitation erosion due to high pressure wave amplitudes, and impact forces on surfaces. However, its intensity changes drastically with the standoff distance between the vibratory horn and workpiece surface. The type of cavitation bubble collapse at the proximity on the surface has been found in two-fold, implosion of bubbles causing erosion of the surface and causation of microjets on the surface, with hemispherical collapse being more aggressive than microjet-type collapse. It has also been confirmed that the frequency of intense bubble collapse is less than one-tenth of the vibration frequency. This study aims to elucidate the mechanism underlying the generation of intense acoustic cavitation bubble collapse. The acoustic cavitation phenomenon was observed using high-speed X-ray imaging with synchrotron radiation at SPring-8 while varying with the standoff distance. Cavitation noise was simultaneously recorded using a hydrophone over 1,000 vibration cycles. It was found that hemispherical bubble collapse produced intense cavitation noise and that hemispherical bubbles gradually grew larger over several vibration cycles. The maximum size of the hemispherical bubble varied with the standoff distance, reaching a peak at a certain standoff distance where cavitation noise amplitude was also maximum.
Acoustic cavitation, which is also called as ultrasonic cavitation, induced by ultrasonic vibration has been used to evaluate cavitation erosion resistance of materials, ultrasonic machiningand chemical engineering. It was known that a large impact does not occur with every cycle of ultrasonic vibration, but rather once every few cycles; however, the mechanism behind this remains unclear. Regarding cavitation collapse, a microjet-type collapse—in which spherical bubble generates a microjet in the bubble—is well known; consequently, it has been believed that ultrasonic cavitation also produces microjet-type collapse. In the present paper, to investigate which type of acoustic cavitation generate intense impacts, acoustic cavitation was investigated by high-speed X-ray imaging with synchrotron radiation at SPring-8 whilst varying the oscillation amplitude by changing with power of ultrasonic vibration from 60–100 %. The oscillation amplitude within the range tested was approximately 41–69 μm. The surface roughness of the tip of the vibratory horn was measured to evaluate plastic deformation associated with cavitation erosion. Within the range of vibration amplitudes tested, hemispherical bubbles were observed, and it was found that the volume of these hemispherical bubbles correlated with the amount of plastic deformation.
1 January 2023 in Journal of Advanced Simulation in Science and Engineering
X-ray phase contrast image has higher sensitivity to materials with light elements than the conventional absorption contrast. Phase image measurement technique using diffraction gratings can be used in the laboratory. Furthermore, X-ray phase microscope using the diffraction gratings has been also developed. However, phase measurement with diffraction gratings has a drawback that the spatial resolution is limited to the grating period. To overcome this problem, a scanning system using a triangular phase grating has recently been proposed, which is expected to archive a large field of view and a high spatial resolution. This study aims to investigate the feasibility of the system and a deep understanding of the optical system by simulation.
1 January 2024 in Journal of Advanced Simulation in Science and Engineering
The phase contrast image has higher sensitivity to materials with light elements than the conventional absorption contrast. The phase image is obtained by computer processing of the measured fringe image. The Fourier transform method is known as a method to obtain a phase image from a single fringe image. However, the method cannot produce images with high spatial resolution. In this study, we present a method to obtain phase images with high spatial resolution using machine learning.