With the modernization of power grids, the network optimal utilization is essential to ensure that voltage profile at each bus is maintained within an acceptable range, voltage stability of the system is enhanced, power losses in lines are minimized, reliability and security of system are improved and etc. These can be achieved by introducing reactive power compensation devices such as Flexible Alternating Current Transmission System (FACTS) devices, Custom Power (CP) devices, synchronous condenser, capacitor bank and etc in distribution or transmission networks. Optimal location and sizing of the reactive power compensation devices are significantly important to ensure sufficient investment onto this device. Recently, most of conducted studies had focused on the techniques for determining the optimal location and sizing of various reactive power compensation devices in the power system using various indices proposed in the literature to access the power loss, voltage stability, voltage profile and line loadability. However, no review paper had discussed on the application of the existing indices adopted in the available techniques for solving the optimal location and sizing problems for all types of reactive power compensation devices. In this paper, current literature survey on optimal location and sizing of reactive power compensations had been discussed which includes analytical, conventional, metaheuristic and hybrid based approaches. The main objectives are to reduce power losses, to mitigate voltage deviations, to increase voltage stability and to improve reliability and security of the system.
Modern power utilization has been forced to operate close to their stability limits, which may lead to voltage instability or collapse owing to the stressed operating conditions of networks. This raises the need to develop a new technique to predict the level of voltage security under different operating conditions to detect critical lines or buses that operate close to its stability limit. This study proposes a new line voltage stability index (BVSI) to identify weak lines and buses for various loading conditions and network configurations. Comparative studies between the existing voltage stability indices (VSIs) and the proposed index have been performed to comprehensively highlight the indices’ foundation, performance, and overall behavior for several different IEEE benchmark test systems; 14-bus, 30-bus, 118-bus test systems and 33-bus radial distribution system. The sensitivity towards different loading conditions due to variables such as active power, reactive power, angular difference between sending and receiving bus voltage, line resistance, and shunt admittance, which have been neglected in the formulation of VSIs, are briefly discussed. The findings of this work are aimed to provide a general guideline for other researchers in selecting the appropriate VSIs for various applications, particularly in solving optimization problems such as distributed generation (DG) and reactive power compensation (RPC) placement, optimal power flow, optimal reactive power dispatch, optimal network reconfiguration for various loading occasions, and different networks. Lastly, the application of the proposed index has been adopted as an analytical approach for solving optimal location and sizing of DG(s) problems. The results prove the effectiveness of the proposed index in accessing the voltage stability state and stress condition of lines. Besides, the proposed approach also capable of determining the potential candidate bus for single DG location and sizing effectively.
1 June 2022 in Bulletin of Electrical Engineering and Informatics
The increasing demand for hybrid energy systems based on renewable energy sources has enabled the new dimension for multi-input converter (MIC). Various topologies have been introduced over the last decade. However, most of these topologies have several drawbacks in terms of design complexity or efficiency. Therefore, this research aims to introduce a multi-input DC-DC converter for hybrid renewable energy applications. The proposed multi-input converter is able to hybridize different sources such as solar PV array and PEMFC. Analysis and simulation have been carried out for the double input two-phase interleaved converter in operating the boost mode. The proposed converter is designed in matlab simulink by using interleaved boost converter method to achieve a boosted and smoothened output. The proposed topology has shown a remarkable performance in terms of output voltage boosting, voltage ripple reduction as well as enhanced efficiency through interleaved boosting technique. From the simulation results, it can be observed that the proposed converter can gain high efficiency which is higher than 97%. The obtained results have been validated with previously published works and the proposed technique has been proven to yield compatible and improved outcomes.
Reliability is an essential role in electricity business as the demand is rising rapidly. Recently, Microgrid technologies have been implemented in the traditional centralized grid in order to mitigate the power disturbance. Many researchers have proposed different configurations of the Microgrid with a constitution of renewable energy sources such as Photovoltaic Plant, Wind Plant and back up supply such as Battery Storage and Uninterruptible Power Supply that offer the reliability improvements. This paper proposes a method of modelling the Photovoltaic plant and Uninterruptible Power Supply system for a small commercial load in OrCAD PSpice simulation tool by implementing the interconnected configuration to perform the reliability estimation test.