Kanendra Naidu

Dr. Kanendra Naidu


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
MKM. Karimi
M. Karimi
Hazlie MokhlisHazlie Mokhlis
Hazlie Mokhlis
KNKanendra Naidu
Kanendra Naidu
SUS. Uddin
S. Uddin
ABA.H.A. Bakar
A.H.A. Bakar

1 January 2017 in Energy
Verified
Journal Article
Closed access
SSShivashankar Sukumar
Shivashankar Sukumar
Hazlie MokhlisHazlie Mokhlis
Hazlie Mokhlis
Saad MekhilefSaad Mekhilef
Saad Mekhilef
KNKanendra Naidu
Kanendra Naidu
Mazaher KarimiMazaher Karimi
Mazaher Karimi

9 December 2020 in IEEE Access
Verified
Journal Article
Open access
BIbazilah ismail
bazilah ismail
NOOR IZZRI ABDUL WAHABNOOR IZZRI ABDUL WAHAB
NOOR IZZRI ABDUL WAHAB
MOMohammad Lutfi Othman
Mohammad Lutfi Othman
MRMohd Amran Mohd Radzi
Mohd Amran Mohd Radzi
KNKanendra Naidu
Kanendra Naidu
MNMuhammad Najwan Mat Naain
Muhammad Najwan Mat Naain
With the modernization of power grids, the network optimal utilization is essential to ensure that voltage profile at each bus is maintained within an acceptable range, voltage stability of the system is enhanced, power losses in lines are minimized, reliability and security of system are improved and etc. These can be achieved by introducing reactive power compensation devices such as Flexible Alternating Current Transmission System (FACTS) devices, Custom Power (CP) devices, synchronous condenser, capacitor bank and etc in distribution or transmission networks. Optimal location and sizing of the reactive power compensation devices are significantly important to ensure sufficient investment onto this device. Recently, most of conducted studies had focused on the techniques for determining the optimal location and sizing of various reactive power compensation devices in the power system using various indices proposed in the literature to access the power loss, voltage stability, voltage profile and line loadability. However, no review paper had discussed on the application of the existing indices adopted in the available techniques for solving the optimal location and sizing problems for all types of reactive power compensation devices. In this paper, current literature survey on optimal location and sizing of reactive power compensations had been discussed which includes analytical, conventional, metaheuristic and hybrid based approaches. The main objectives are to reduce power losses, to mitigate voltage deviations, to increase voltage stability and to improve reliability and security of the system.

1 February 2014 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
KNKanendra Naidu
Kanendra Naidu
Hazlie MokhlisHazlie Mokhlis
Hazlie Mokhlis
ABA.H.A. Bakar
A.H.A. Bakar

1 December 2014 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
KNKanendra Naidu
Kanendra Naidu
Hazlie MokhlisHazlie Mokhlis
Hazlie Mokhlis
ABA.H.A. Bakar
A.H.A. Bakar
VTV. Terzija
V. Terzija
HIH.A. Illias
H.A. Illias

25 July 2019 in Electronics
Verified
Journal Article
Open access
PDF file
MJM. Kamran Joyo
M. Kamran Joyo
YRYarooq Raza
Yarooq Raza
SAS. Faiz Ahmed
S. Faiz Ahmed
MBM. M. Billah
M. M. Billah
KKKushsairy Kadir
Kushsairy Kadir
ZYZukhairi Mohd Yusof
Zukhairi Mohd Yusof
This paper proposes a nature inspired, meta-heuristic optimization technique to tune a proportional-integral-derivative (PID) controller for a robotic arm exoskeleton RAX-1. The RAX-1 is a two-degrees-of-freedom (2-DOFs) upper limb rehabilitation robotic system comprising two joints to facilitate shoulder joint movements. The conventional tuning of PID controllers using Ziegler-Nichols produces large overshoots which is not desirable for rehabilitation applications. To address this issue, nature inspired algorithms have recently been proposed to improve the performance of PID controllers. In this study, a 2-DOF PID control system is optimized offline using particle swarm optimization (PSO) and artificial bee colony (ABC). To validate the effectiveness of the proposed ABC-PID method, several simulations were carried out comparing the ABC-PID controller with the PSO-PID and a classical PID controller tuned using the Zeigler-Nichols method. Various investigations, such as determining system performance with respect to maximum overshoot, rise and settling time and using maximum sensitivity function under disturbance, were carried out. The results of the investigations show that the ABC-PID is more robust and outperforms other tuning techniques, and demonstrate the effective response of the proposed technique for a robotic manipulator. Furthermore, the ABC-PID controller is implemented on the hardware setup of RAX-1 and the response during exercise showed minute overshoot with lower rise and settling times compared to PSO and Zeigler-Nichols-based controllers.