Toshiyuki Satoh

Toshiyuki Satoh


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2014 in International Journal of Computers Communications & Control
Verified
Journal Article
Open access
PDF file
TSToshiyuki Satoh
Toshiyuki Satoh
KKKotaro Kaneko
Kotaro Kaneko
NSNaoki Saito
Naoki Saito
A practical approach for improving tracking performance of the predictive functional control (PFC) is proposed. The disturbance observer is utilized to nominalize the actual plant and to reduce the predicted output error in the PFC algorithm by canceling not only constant but also high-order disturbances. The proposed control scheme is experimentally validated on a single axis table drive system and is compared with the standard PFC and the industrial cascade control. The experimental results prove the effectiveness of the proposed disturbance observer-based PFC scheme.

26 July 2024 in Actuators
Verified
Journal Article
Open access
PDF file
NSNaoki Saito
Naoki Saito
TSToshiyuki Satoh
Toshiyuki Satoh
NSNorihiko Saga
Norihiko Saga
In this paper, we propose a double air chambers artificial muscle to eliminate the hysteresis in the extension and contraction movement of pneumatic artificial muscles. In this paper, the basic structure of the double air chambers artificial muscle is a rubberless artificial muscle with a particularly large hysteresis loop. The double air chambers artificial muscle aims to eliminate hysteresis by directly pressurizing the inside and outside of the air chamber and actively deforming the air chamber. The hysteresis is reduced by the pressure outside of the air chamber (external pressure). Since the appropriate external pressure varies depending on the contraction force and amount of contraction, we proposed a method to regulate the appropriate external pressure by feedback control. The experimental results show that hysteresis was eliminated in the static characteristics. It was also found that the output gain decreased, and the phase lag increased as the target frequency increased. The output gain did not change with increasing load. The phase lag tended to improve with the PID controller compared to the PI controller. These results suggest that the combination of double air chambers artificial muscle and external pressure-regulated feedback control can achieve non-hysteresis position control, and it is useful as an actuator in mechatronic systems.

19 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
NSNorihiko Saga
Norihiko Saga
KSKunio Shimada
Kunio Shimada
DIDouhaku Inamori
Douhaku Inamori
NSNaoki Saito
Naoki Saito
TSToshiyuki Satoh
Toshiyuki Satoh
JNJun-ya Nagase
Jun-ya Nagase
Shortage of labor and increased work of young people are causing problems in terms of care and welfare of a growing proportion of elderly people. This is a looming social problem because people of advanced ages are increasing. Necessary in the fields of care and welfare, pneumatic artificial muscles in actuators of robots are being examined. Pneumatic artificial muscles have a high output per unit of weight, and they are soft, similarly to human muscles. However, in previous research of robots using pneumatic artificial muscles, rigid sensors were often installed at joints and other locations due to the robots’ structures. Therefore, we developed a smart actuator that integrates a bending sensor that functions as a human muscle spindle; it can be externally attached to the pneumatic artificial muscle. This paper reports a smart artificial muscle actuator that can sense contraction, which can be applied to developed self-monitoring and robot posture control.

26 June 2019 in Industrial Robot: the international journal of robotics research and application
Verified
Journal Article
Closed access
NSNaoki Saito
Naoki Saito
TSToshiyuki Satoh
Toshiyuki Satoh
NSNorihiko Saga
Norihiko Saga
Purpose: The purpose of this study is to confirm that the body weight load reduction system which is developed by us is effective to reduce the knee joint force of the walking user. This system is driven by pneumatic artificial muscle, functions as a mobile walking assist system. Design/methodology/approach: The developed body weight load reduction system driven by rubber-less artificial muscle (RLAM) was tested experimentally. Simple force feedback control is applied to the RLAM. The system moves as synchronized with vertical movement of the walking user. The knee joint force during walking experiments conducted using this system is estimated by measurement of floor reaction force and position data of lower limb joints. Findings: The knee joint force during walking is reduced when using this system. This system contributes to smooth change of knee joint force when the lower limb contacts the floor. Practical implications: This lightweight body weight load reduction system is particularly effective for realizing easy-to-use mobile walking assist system. Originality/value: A lightweight body weight load reduction system using pneumatic artificial muscle is a novel proposal. Additionally, these new evaluation results demonstrate its effectiveness for reducing knee joint force during walking.

15 July 2024 in Electronics
Verified
Journal Article
Open access
PDF file
NSNorihiko Saga
Norihiko Saga
YOYukina Okawa
Yukina Okawa
TSTakuma Saga
Takuma Saga
TSToshiyuki Satoh
Toshiyuki Satoh
NSNaoki Saito
Naoki Saito
Most BCI systems used in neurorehabilitation detect EEG features indicating motor intent based on machine learning, focusing on repetitive movements, such as limb flexion and extension. These machine learning methods require large datasets and are time consuming, making them unsuitable for same-day rehabilitation training following EEG measurements. Therefore, we propose a BMI system based on fuzzy inference that bypasses the need for specific EEG features, introducing an algorithm that allows patients to progress from measurement to training within a few hours. Additionally, we explored the integration of electromyography (EMG) with conventional EEG-based motor intention estimation to capture continuous movements, which is essential for advanced motor function training, such as skill improvement. In this study, we developed an algorithm that detects the initial movement via EEG and switches to EMG for subsequent movements. This approach ensures real-time responsiveness and effective handling of continuous movements. Herein, we report the results of this study.

23 March 2023 in Information Sciences
Verified
Journal Article
Closed access
TSToshiyuki Satoh
Toshiyuki Satoh
SNShun Nishizawa
Shun Nishizawa
JNJun-ya Nagase
Jun-ya Nagase
NSNaoki Saito
Naoki Saito
NSNorihiko Saga
Norihiko Saga