Pedro Fonseca

Dr. Pedro Fonseca

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2021 in Scientific Data
Verified
Journal Article
Open access
PDF file
LMLuís Moreira
Luís Moreira
Joana FigueiredoJoana Figueiredo
Joana Figueiredo
PFPedro Fonseca
Pedro Fonseca
João Paulo Vilas-BoasJoão Paulo Vilas-Boas
João Paulo Vilas-Boas
Cristina SantosCristina Santos
Cristina Santos
Understanding the lower limb kinematic, kinetic, and electromyography (EMG) data interrelation in controlled speeds is challenging for fully assessing human locomotion conditions. This paper provides a complete dataset with the above-mentioned raw and processed data simultaneously recorded for sixteen healthy participants walking on a 10 meter-flat surface at seven controlled speeds (1.0, 1.5, 2.0, 2.5, 3.0, 3.5, and 4.0 km/h). The raw data include 3D joint trajectories of 24 retro-reflective markers, ground reaction forces (GRF), force plate moments, center of pressures, and EMG signals from Tibialis Anterior, Gastrocnemius Lateralis, Biceps Femoris, and Vastus Lateralis. The processed data present gait cycle-normalized data including filtered EMG signals and their envelope, 3D GRF, joint angles, and torques. This study details the experimental setup and presents a brief validation of the data quality. The presented dataset may contribute to (i) validate and enhance human biomechanical gait models, and (ii) serve as a reference trajectory for personalized control of robotic assistive devices, aiming an adequate assistance level adjusted to the gait speed and user’s anthropometry.

31 August 2018 in Sports
Verified
Journal Article
Open access
PDF file
VRVincenzo Rago
Vincenzo Rago
JBJoão Brito
João Brito
Pedro FigueiredoPedro Figueiredo
Pedro Figueiredo
TCThiago Carvalho
Thiago Carvalho
TFTiago Fernandes
Tiago Fernandes
ARAntonio Rebelo
Antonio Rebelo
The aim of this study was to analyze the concurrent validity, test–retest reliability, and capacity to detect changes of four different portable devices used to measure a wide range of neuromuscular parameters derived from countermovement jump (CMJ). An accelerometric device (Myotest), a jump mat (Ergojump), an optical device (Optojump), and a smartphone app (MyJump) were simultaneously examined for concurrent validity against gold-standard measures (motion-capture system and a force platform). Twenty-two CMJ-derived variables were collected from 15 healthy male subjects (n = 60 CMJs). Contraction time (CT) and eccentric duration (EccD) measurements obtained from the Myotest were moderately to largely associated with and not different from force platform measurements (r = 0.31 to 0.64, ES = 0.11 to 0.18) and showed moderate test-retest reliability (intraclass correlation coefficient (ICC) = 0.92 to 0.97, coefficient of variation (CV) = 3.8 to 8.0%). Flight time (FT) and jump height (JH) from Ergojump, Optojump, and MyJump showed moderate to strong associations with gold-standard measurements (r = 0.57 to 0.98) and good test–retest reliability (ICC = 0.54 to 0.97, CV = 1.8 to 4.2). However, all portable devices underestimated JH (ES = 1.25 to 2.75). Independent of the instrument used, the analyzed CMJ variables showed good capacity to detect changes (standard error of measurement (SEM) < smallest worthwhile change (SWC)), with the exception of rate of force and rate of power development parameters, which showed marginal capacity (SEM > SWC). The Myotest is preferable to measure temporal parameters during ground contact, whereas Ergojump, Optojump, and MyJump devices may be preferable to measure FT and JH, with the Optojump being the most accurate.

8 March 2019 in Sports
Verified
Journal Article
Open access
PDF file
EGEduardo Guimarães
Eduardo Guimarães
Adam Baxter-JonesAdam Baxter-Jones
Adam Baxter-Jones
Jose MaiaJose Maia
Jose Maia
PFPedro Fonseca
Pedro Fonseca
ASAmérico Santos
Américo Santos
MJManuel António Janeira
Manuel António Janeira
This study investigated the roles of growth, maturation, physical fitness, and technical skills on selection onto an under-14 years basketball team. The sample consisted of 150 male players, aged 13.3 ± 0.7 years, divided into selected (SE—top players chosen by coaching staff to form an elite regional team) and non-selected (NSE—remaining players) groups. Anthropometry, body composition, biological maturation, and training experience data were collected using standard procedures. Physical fitness was assessed using the Yo-Yo IE2, sit-ups, handgrip, squat jump, countermovement jump, 3 kg medicine ball throw, 20 m sprint, and T-Test. Technical skills were acquired using the American Alliance for Health, Physical Education, Recreation, and Dance (AAHPERD)’s basketball-specific test battery. Groups were compared using a Student’s t test and multivariate analysis of covariance (MANCOVA), with training experience and biological maturation as covariates. A forward stepwise discriminant function analysis was employed to identify variables that maximized the separation between groups. The results showed that SE players were taller, had greater fat-free mass, greater strength, power, and agility, and were technically more skillful compared with NSE players (p < 0.05) when controlling for training experience and maturation. It was also found that players were best discriminated by the 3 kg medicine ball throw and control dribble, revealing the importance of qualified training to achieve excellence in youth basketball. 92.7% of the basketballers were correctly classified into their original groups. It is therefore confirmed that the additional effects of training experience and biological maturation positively influenced the performance of young basketball players. We recommend that coaches focus not only on players’ body sizes, but also on their skill level, especially during adolescence, when selecting teams in order to promote sustainable long-term development.

20 February 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
MCMarcelo de Castro
Marcelo de Castro
MMMarco Meucci
Marco Meucci
DSDenise Paschoal Soares
Denise Paschoal Soares
PFPedro Fonseca
Pedro Fonseca
Marcio Borgonovo-SantosMarcio Borgonovo-Santos
Marcio Borgonovo-Santos
João Paulo Vilas-BoasJoão Paulo Vilas-Boas
João Paulo Vilas-Boas
WalkinSense is a new device designed to monitor walking. The aim of this study was to measure the accuracy and repeatability of the gait analysis performed by the WalkinSense system. Descriptions of values recorded by WalkinSense depicting typical gait in adults are also presented. A bench experiment using the Trublu calibration device was conducted to statically test the WalkinSense. Following this, a dynamic test was carried out overlapping the WalkinSense and the Pedar insoles in 40 healthy participants during walking. Pressure peak, pressure peak time, pressure-time integral, and mean pressure at eight-foot regions were calculated. In the bench experiments, the repeatability (i) among the WalkinSense sensors (within), (ii) between two WalkinSense devices, and (iii) between the WalkinSense and the Trublu devices was excellent. In the dynamic tests, the repeatability of the WalkinSense (i) between stances in the same trial (within-trial) and (ii) between trials was also excellent (ICC > 0.90). When the eight-foot regions were analyzed separately, the within-trial and between-trials repeatability was good-to-excellent in 88% (ICC > 0.80) of the data and fair in 11%. In short, the data suggest that the WalkinSense has good-to-excellent levels of accuracy and repeatability for plantar pressure variables.

1 March 2024 in International Journal of Sports Physiology and Performance
Verified
Journal Article
Closed access
PDF file
Manoel J. RiosManoel J. Rios
Manoel J. Rios
Klaus Magno BeckerKlaus Magno Becker
Klaus Magno Becker
AMAna Sofia Monteiro
Ana Sofia Monteiro
PFPedro Fonseca
Pedro Fonseca
DPDavid Pyne
David Pyne
Ricardo FernandesRicardo Fernandes
Ricardo Fernandes
Purpose: Fran is one of the most popular CrossFit benchmark workouts used to control CrossFitters’ improvements. Detailed physiological characterization of Fran is needed for a more specific evaluation of CrossFitters’ training performance improvements. The aim of the study was to analyze the oxygen uptake () kinetics and characterize the energy system contributions and the degree of postexercise fatigue of the unbroken Fran. Methods: Twenty trained CrossFitters performed Fran at maximal exertion. and heart-rate kinetics were assessed at baseline and during and post-Fran. Blood lactate and glucose concentrations and muscular fatigue were measured at baseline and in the recovery period. Results: A marked increase in kinetics was observed at the beginning of Fran, remaining elevated until the end (: 49.2 [3.7] mL·kg−1·min−1, amplitude: 35.8 [5.2] mL·kg−1·min−1, time delay: 4.7 [2.5] s and time constant: 23.7 [11.1] s; mean [SD]). Aerobic, anaerobic lactic, and alactic pathways accounted for 62% (4%), 26% (4%), and 12% (2%) of energy contribution. Reduction in muscle function in jumping ability (jump height: 8% [6%], peak force: 6% [4%], and maximum velocity: 4% [2%]) and plank prone test (46% [20%]) was observed in the recovery period. Conclusions: The Fran unbroken workout is a high-intensity effort associated with an elevated metabolic response. This pattern of energy response highlights the primary contribution of aerobic energy metabolism, even during short and very intense CrossFit workouts, and that recovery can take >24 hours due to cumulative fatigue.

18 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JLJoão Mendes Lopes
João Mendes Lopes
Joana FigueiredoJoana Figueiredo
Joana Figueiredo
PFPedro Fonseca
Pedro Fonseca
JCJoao Jose Cerqueira
Joao Jose Cerqueira
João Paulo Vilas-BoasJoão Paulo Vilas-Boas
João Paulo Vilas-Boas
Cristina SantosCristina Santos
Cristina Santos
Energy expenditure is a key rehabilitation outcome and is starting to be used in robotics-based rehabilitation through human-in-the-loop control to tailor robot assistance towards reducing patients’ energy effort. However, it is usually assessed by indirect calorimetry which entails a certain degree of invasiveness and provides delayed data, which is not suitable for controlling robotic devices. This work proposes a deep learning-based tool for steady-state energy expenditure estimation based on more ergonomic sensors than indirect calorimetry. The study innovates by estimating the energy expenditure in assisted and non-assisted conditions and in slow gait speeds similarly to impaired subjects. This work explores and benchmarks the long short-term memory (LSTM) and convolutional neural network (CNN) as deep learning regressors. As inputs, we fused inertial data, electromyography, and heart rate signals measured by on-body sensors from eight healthy volunteers walking with and without assistance from an ankle-foot exoskeleton at 0.22, 0.33, and 0.44 m/s. LSTM and CNN were compared against indirect calorimetry using a leave-one-subject-out cross-validation technique. Results showed the suitability of this tool, especially CNN, that demonstrated root-mean-squared errors of 0.36 W/kg and high correlation (ρ > 0.85) between target and estimation (R¯2 = 0.79). CNN was able to discriminate the energy expenditure between assisted and non-assisted gait, basal, and walking energy expenditure, throughout three slow gait speeds. CNN regressor driven by kinematic and physiological data was shown to be a more ergonomic technique for estimating the energy expenditure, contributing to the clinical assessment in slow and robotic-assisted gait and future research concerning human-in-the-loop control.