Salvatore Mauro

Dr. Salvatore Mauro

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Ocean Engineering
Verified
Journal Article
Closed access
FOFabrizio Ortolani
Fabrizio Ortolani
SMSalvatore Mauro
Salvatore Mauro
GDGiulio Dubbioso
Giulio Dubbioso

Verified
Journal Article
Open access
PDF file
FOFabrizio Ortolani
Fabrizio Ortolani
GDGiulio Dubbioso
Giulio Dubbioso
RMRoberto Muscari
Roberto Muscari
SMSalvatore Mauro
Salvatore Mauro
AMAndrea Di Mascio
Andrea Di Mascio
The understanding of the performance of a propeller in realistic operative conditions is nowadays a key issue for improving design techniques, guaranteeing safety and continuity of operation at sea, and reducing maintenance costs. In this paper, a summary of the recent research carried out at CNR-INSEAN devoted to the analysis of propeller loads in realistic operative scenarios, with particular emphasis on the in-plane loads, is presented. In particular, the experimental results carried out on a free running maneuvering model equipped with a novel force transducer are discussed and supported by C F D (Computational Fluid Dynamics) analysis and the use of a simplified propeller model, based on Blade Element Momentum Theory, with the aim of achieving a deeper understanding of the mechanisms that govern the functioning of the propeller in off-design. Moreover, the analysis includes the scaling factors that can be used to obtain a prediction from model measurements, the propeller radial force being the primary cause of failures of the shaft bearings. In particular, the analysis highlighted that cavitation at full scale can cause the increment of in-plane loads by about 20% with respect to a non-cavitating case, that that in-plane loads could be more sensitive to cavitation than thrust and torque, and that Reynolds number effect is negligible. For the analysis of cavitation, an alternative version of the B E M T solver, improved with cavitation linear theory, was developed.

4 July 2018 in ACTA IMEKO
Verified
Journal Article
Open access
ABAlper Biber
Alper Biber
AKAta Can Korakci
Ata Can Korakci
AGAlexander Golick
Alexander Golick
SRStephen Robinson
Stephen Robinson
GHGary Hayman
Gary Hayman
PDPer Davidsson
Per Davidsson
The project entitled “UNderwater Acoustic Calibration standards for frequencies beLOW 1 kHz” (“UNAC-LOW”), currently active within the European Metrology Programme for Innovation and Research (EMPIR), is presented by describing its objectives and current activities. The project aims at developing the metrological capacity of the European Union (EU) for the calibration of hydrophones and autonomous recording systems for the frequency range between 20 Hz and 1 kHz, for which traceability is presently not fully available. In this way, EU metrological capacities for absolute measurement of underwater sound will be improved, with a direct effect on the implementation of regulation and EU Directives that require underwater acoustic measurements to be traceable. After having completed the initial project tasks regarding the review of existing methods and the design of the experimental setups, comparison measurements between the project partners are currently under way and their results will be validated and presented upon project end after first quarter of 2019. To ensure long-term operation of the calibration capabilities by each partner, a coherent EU metrology strategy for underwater acoustics will be developed as one of the main project outcomes. Current activities include the implementation of the calibration setups developed in earlier stages of the project for both hydrophones and autonomous recorders. The methods that shall be used for hydrophones are the pressure method in a closed chamber and the standing wave tube method. For autonomous recorders, in addition to the above methods, calibrations will be performed using free-field methods in different open-water test sites possessing suitable characteristics for low frequency measurements.