Joanna Maszybrocka

Dr. Joanna Maszybrocka

University of Silesia in Katowice, Faculty of Science and Technology, Institute of Materials Engineering
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2019 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Open access
PDF file
JMJoanna Maszybrocka
Joanna Maszybrocka
Bartosz GapińskiBartosz Gapiński
Bartosz Gapiński
MDMichał Dworak
Michał Dworak
GSGrzegorz Skrabalak
Grzegorz Skrabalak
ASAndrzej Stwora
Andrzej Stwora
Selective laser melting technology makes it possible to produce 3D cellular lattice structures with controlled porosity. The paper reflects to machining and examination of structures with predefined distribution, shape and size of the pores. In the study, the porous structures of Ti6Al4V were investigated. The tests were carried out using structures of spatial architecture of Schwarz D TPMS geometry with a total porosity of 60% and 80% and various pore sizes. Dimensional accuracy of additively manufactured structures was measured in relation to the 3D model. Geometry of the final structure differed from the CAD model in the range ± 0.3 mm. The surface morphology and porosity of the solid struts were also checked. The mechanical properties of the structures were determined in a static compression test.

1 August 2018 in Materials Characterization
Verified
Journal Article
Closed access
Grzegorz DerczGrzegorz Dercz
Grzegorz Dercz
IMIzabela Matuła
Izabela Matuła
MZMaciej Zubko
Maciej Zubko
AKAlicja Kazek-Kęsik
Alicja Kazek-Kęsik
JMJoanna Maszybrocka
Joanna Maszybrocka
IJIzabela Jendrzejewska
Izabela Jendrzejewska

19 January 2025 in Coatings
Verified
Journal Article
Open access
PDF file
BŁBożena Łosiewicz
Bożena Łosiewicz
POPatrycja Osak
Patrycja Osak
DNDelfina Nowińska
Delfina Nowińska
JMJoanna Maszybrocka
Joanna Maszybrocka
The development of dental implants has significantly advanced due to technological innovations aimed at improving their performance and patient outcomes. This work presents key factors influencing the success of dental implants, including osseointegration, which is the direct connection between living bone and the implant surface, and the various surface modifications that enhance this process. This review highlights the importance of surface roughness, chemical composition, and the use of bioactive coatings to promote better integration with surrounding bone tissue. Innovations such as nanotechnology, 3D printing, and smart surfaces are paving the way for more effective and personalized dental implant solutions. This review underscores the importance of ongoing research and development to improve success rates, enhance patient comfort, and reduce healing times. It focuses on creating cost-effective, reliable methods that integrate multiple functions, such as combining antibacterial and osteoconductive properties to improve overall implant performance.

10 February 2022 in Materials
Verified
Journal Article
Open access
PDF file
JMJoanna Maszybrocka
Joanna Maszybrocka
MDMichał Dworak
Michał Dworak
GNGrażyna Dominika Nowakowska
Grażyna Dominika Nowakowska
POPatrycja Osak
Patrycja Osak
BŁBożena Łosiewicz
Bożena Łosiewicz
Three-dimensional printing is a dynamically developing field of industry. Its main advantage is the small amount of waste, no need to use specialized tools, and easy control of the mechanical properties of the printed model. One of the most popular techniques of 3D printing is FDM. The main factor influencing the mechanical properties of 3D-printed materials is the filling density. The aim of this study was to determine the mechanical properties of porous structures with a porosity gradient of PLA samples printed using the FDM technique. The accuracy of mapping the structures by computed tomography was assessed, and then a static compression test was performed. It has been shown that the strength properties increased with the increase in the filling density. The highest value of compression strength, amounting to 41.2 MPa, was observed for samples made of PLA with an 80% filling degree, whereas the lowest value of compression strength was found in PLA-T samples with a filling degree of 10%, reaching only 0.6 MPa. It was found that not only the core filling density, but also the outer layers, influences the mechanical properties. The assessment of spatial architecture allowed for a qualitative and quantitative assessment. The obtained images from the computed tomograph showed that the designed sample models were correctly reproduced in the entire volume.

18 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
BŁBożena Łosiewicz
Bożena Łosiewicz
POPatrycja Osak
Patrycja Osak
JMJoanna Maszybrocka
Joanna Maszybrocka
JKJulian Kubisztal
Julian Kubisztal
Sebastian StachSebastian Stach
Sebastian Stach
Titanium Grade 4 (Ti G4) is the most commonly used material for dental implants due to its excellent mechanical properties, chemical stability and biocompatibility. A thin, self-passive oxide layer with protective properties to corrosion is formed on its surface. However, the spontaneous TiO2 layer is chemically unstable. In this work, the impact of autoclaving time on corrosion resistance of Ti G4 in artificial saliva solution with pH = 7.4 at 37 °C was studied. Ti G4 was sandblasted with white Al2O3 particles and autoclaved for 30–120 min. SEM, EDS, 2D roughness profiles, confocal laser scanning microscopy, and a Kelvin scanning probe were used for the surface characterization of the Ti G4 under study. In vitro corrosion resistance tests were conducted using open circuit potential, polarization curves, and electrochemical impedance spectroscopy measurements. It was found that Sa parameter, electron work function, and thickness of the oxide layers, determined based on impedance measurements, increased after autoclaving. The capacitive behavior and high corrosion resistance of tested materials were revealed. The improvement in the corrosion resistance after autoclaving was due to the presence of oxide layers with high chemical stability. The optimal Ti G4 surface for dentistry can be obtained by sandblasting with Al2O3 with an average grain size of 53 µm, followed by autoclaving for 90 min.

1 February 2017 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
Verified
Journal Article
Open access
PDF file
JMJoanna Maszybrocka
Joanna Maszybrocka
ASA. Stwora
A. Stwora
Bartosz GapińskiBartosz Gapiński
Bartosz Gapiński
GSG. Skrabalak
G. Skrabalak
Małgorzata KarolusMałgorzata Karolus
Małgorzata Karolus
Construction of metallic implants with a porous structure that mimics the biomechanical properties of bone is one of the challenges of orthopedic regenerative medicine. The selective laser sintering technique (SLS) allows the production of complex geometries based on three-dimensional model, which offers the prospect of preparing porous metal implants, in which stiffness and porosity can be precisely adjusted to the individual needs of the patient. This requires an interdisciplinary approach to design, manufacturing and testing of porous structures manufactured by selective sintering. An important link in this process is the ability to assess the surface topography of the struts of porous structure. The paper presents a qualitative assessment of the surface morphology based on SEM studies and methodology that allows for quantitative assessment of stereometric structure based on micro-tomographic measurements.