Julian Kubisztal

Dr. Julian Kubisztal

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2007 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
JKJulian Kubisztal
Julian Kubisztal
ABA Budniok
A Budniok
ALA Lasia
A Lasia

1 September 2008 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
JKJulian Kubisztal
Julian Kubisztal
ABA. Budniok
A. Budniok

6 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
MPMagdalena Popczyk
Magdalena Popczyk
JKJulian Kubisztal
Julian Kubisztal
Andrzej S. SwinarewAndrzej S. Swinarew
Andrzej S. Swinarew
Zbigniew WaśkiewiczZbigniew Waśkiewicz
Zbigniew Waśkiewicz
Arkadiusz StanulaArkadiusz Stanula
Arkadiusz Stanula
Beat KnechtleBeat Knechtle
Beat Knechtle
The paper presents research on evaluation of corrosion resistance of Ni-W alloy coatings subjected to heat treatment. The corrosion resistance was tested in 5% NaCl solution by the use of potentiodynamic polarization technique and electrochemical impedance spectroscopy. Characteristics of the Ni-W coatings after heat treatment were carried out using scanning electron microscopy, scanning Kelvin probe technique and X-ray diffraction. Suggested reasons for the improvement of properties of the heat treated Ni-W coating, obtained at the lowest current density value (125 mA∙cm−2), are the highest tungsten content (c.a. 25 at.%) as well as the smallest and the most homogeneous electrochemically active surface area.

18 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
BŁBożena Łosiewicz
Bożena Łosiewicz
POPatrycja Osak
Patrycja Osak
JMJoanna Maszybrocka
Joanna Maszybrocka
JKJulian Kubisztal
Julian Kubisztal
Sebastian StachSebastian Stach
Sebastian Stach
Titanium Grade 4 (Ti G4) is the most commonly used material for dental implants due to its excellent mechanical properties, chemical stability and biocompatibility. A thin, self-passive oxide layer with protective properties to corrosion is formed on its surface. However, the spontaneous TiO2 layer is chemically unstable. In this work, the impact of autoclaving time on corrosion resistance of Ti G4 in artificial saliva solution with pH = 7.4 at 37 °C was studied. Ti G4 was sandblasted with white Al2O3 particles and autoclaved for 30–120 min. SEM, EDS, 2D roughness profiles, confocal laser scanning microscopy, and a Kelvin scanning probe were used for the surface characterization of the Ti G4 under study. In vitro corrosion resistance tests were conducted using open circuit potential, polarization curves, and electrochemical impedance spectroscopy measurements. It was found that Sa parameter, electron work function, and thickness of the oxide layers, determined based on impedance measurements, increased after autoclaving. The capacitive behavior and high corrosion resistance of tested materials were revealed. The improvement in the corrosion resistance after autoclaving was due to the presence of oxide layers with high chemical stability. The optimal Ti G4 surface for dentistry can be obtained by sandblasting with Al2O3 with an average grain size of 53 µm, followed by autoclaving for 90 min.

25 April 2021 in Coatings
Verified
Journal Article
Open access
PDF file
Krzysztof AniołekKrzysztof Aniołek
Krzysztof Aniołek
BŁBożena Łosiewicz
Bożena Łosiewicz
JKJulian Kubisztal
Julian Kubisztal
POPatrycja Osak
Patrycja Osak
ASAgnieszka Stróż
Agnieszka Stróż
Sławomir KaptaczSławomir Kaptacz
Sławomir Kaptacz
Titanium and its alloys are among the most promising biomaterials for medical applications. In this work, the isothermal oxidation of Ti-6Al-7Nb biomedical alloy towards improving its mechanical properties, corrosion resistance, and bioactivity has been developed. The oxide layers were formed at 600, 700, and 800 °C for 72 h. Scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), 3D profilometry, and microindentation test, were used to characterize microstructure, surface geometrical structure, and the hardness of the diphase (α + β) Ti-6Al-7Nb alloy after oxidation, respectively. In vitro corrosion resistance tests were carried out in a saline solution at 37 °C using the open-circuit potential method and potentiodynamic measurements. Electronic properties in the air were studied using the Scanning Kelvin Probe (SKP) technique. The bioactivity test was conducted by soaking the alkali- and heat-treated samples in simulated body fluid for 7 days. The presence of apatite was confirmed using SEM/EDS and Fourier Transform Infrared Spectroscopy (FTIR) studies. The thickness of oxide layers formed increased with the temperature growth from 0.25 to 5.48 µm. It was found that with increasing isothermal oxidation temperature, the surface roughness, hardness, corrosion resistance, and contact potential difference increased. The Ti-6Al-7Nb alloy after oxidation revealed the HAp-forming ability in a biological environment.

1 January 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
JKJulian Kubisztal
Julian Kubisztal
MKMarian Kubisztal
Marian Kubisztal