Jian Liu

Jian Liu


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2019 in Optics Letters
Verified
Journal Article
Open access
PDF file
HZHe Zhang
He Zhang
ZBZichao Bian
Zichao Bian
SJShaowei Jiang
Shaowei Jiang
Jian LiuJian Liu
Jian Liu
PSPengming Song
Pengming Song
GZGuoan Zheng
Guoan Zheng
We report a compact, cost-effective, and field-portable lensless imaging platform for quantitative microscopy. In this platform, the object is placed on top of an image sensor chip without using a lens. We use a low-cost galvo scanner to rapidly scan an unknown laser speckle pattern on the object. To address the positioning repeatability and accuracy issues, we directly recover the positional shifts of the speckle pattern based on the phase correlation of the captured images. To bypass the resolution limit set by the imager pixel size, we employ a sub-sampled ptychographic phase retrieval process to recover the complex object. We validate our approach using a resolution target, phase target, and biological sample. Our results show that accurate, high-quality complex images can be obtained from a lensless dataset with as few as ∼10 images. We also demonstrate the reported approach to achieve a 6.4-mm by 4.6-mm field of view and a half-pitch resolution of 1 μm. The reported approach may provide a quantitative lensless imaging strategy for addressing point-of-care-, global-health-, and telemedicine-related challenges.

3 November 2009 in Applied Optics
Verified
Journal Article
Closed access
PDF file
Jian LiuJian Liu
Jian Liu
JTJiubin Tan
Jiubin Tan
HBHu Bin
Hu Bin
YWYuhang Wang
Yuhang Wang
Improved differential confocal microscopy is proposed to improve axial resolution and to enhance disturbance resistibility of confocal microscopy. The subtraction and sum values of the two defocusing detected signals are divided as the response function. Both ultrahigh signal-to-noise ratio (SNR) and wide range can be selectively obtained by controlling the defocusing amount of the two differential detectors more tightly with the reflectance disturbance resistibility. Since the detecting sensitivity of the proposed confocal microscopy is unrelated to the energy loss of the reflected beam, the multiplicative mode disturbance can be used to measure microstructures made of hybrid materials and overcome the power drift of a laser source during long scanning. In the case of ultrahigh SNR, the axial resolution reaches 1 nm when NA=0.75 and λ=632.8 nm.

9 March 2022 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
DSDeer Su
Deer Su
XWXinwei Wang
Xinwei Wang
GSGuanyu Shang
Guanyu Shang
Xumin DingXumin Ding
Xumin Ding
Shah Nawaz BurokurShah Nawaz Burokur
Shah Nawaz Burokur
HLHaoyu Li
Haoyu Li
Designed metasurfaces, composed of a two-dimensional array of meta-atoms, provide an alternative approach to achieving efficient electromagnetic wave manipulation. Metasurface holography is an emerging and promising imaging technology, with improved image quality and spatial resolution compared to traditional holography. Many devices are fabricated only by coding specific phase responses of the designed metasurfaces. However, the modulation of both the amplitude and phase responses of electromagnetic waves can significantly improve the quality of the holographic image. In this paper, we employ bi-layered split rings as meta-atoms, which can fully control the transmission amplitude and phase independently. Furthermore, we present an algorithm based on the inverse angular spectrum diffraction theory to obtain the amplitude and phase information for the shape and arrangement of the meta-atoms. The proof-of-concept experiments in the microwave regime demonstrate that the inverse angular spectrum diffraction theory shows better image quality than the conventional Gerchberg-Saxton algorithm, especially when the number of meta-atoms is the same or even slightly fewer. The proposed approach provides an innovative and effective method for hologram design and expands the route to versatile applications related to holographic technologies.

18 September 2017 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
CLChenguang Liu
Chenguang Liu
YLYan Liu
Yan Liu
TZTingting Zheng
Tingting Zheng
JTJiubin Tan
Jiubin Tan
Jian LiuJian Liu
Jian Liu
Localisation of axial peaks is essential for height determination in confocal microscopy. Several algorithms have been proposed for reliable height extraction in surface topography measurements. However, most of these algorithms use nonlinear processing, which precludes estimating the peak height uncertainty. A Monte Carlo based standard uncertainty analysis model is developed here to evaluate the precision of height extraction algorithms. The key parameters of this model are the vertical sampling deviation and the size of the scanning pitch. Height extraction uncertainty of the centroid algorithm and nonlinear fitting algorithms were calculated using simulations. Our results offer a reference for selecting algorithms for confocal metrology.

7 December 2022 in Journal of Microscopy
Verified
Journal Article
Closed access
XYXiaoyu You
Xiaoyu You
JLJing Liu
Jing Liu
YLYifei Li
Yifei Li
YJYong Jiang
Yong Jiang
Jian LiuJian Liu
Jian Liu

28 August 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
Jian LiuJian Liu
Jian Liu
JTJiubin Tan
Jiubin Tan
CZChenguang Zhao
Chenguang Zhao
ZGZhenggui Ge
Zhenggui Ge
DZDaqing Zhang
Daqing Zhang
A phase-shift resolving equation is established by combining the phase-shift interference and tomographic ability of a point detector. The theoretical measuring range of confocal microscopy is extended from the single-side linear range of an axial main lobe into the almost complete envelope of an axial main lobe, and the axial tomographic measurement is thus made resistible to the reflectance disturbance and power drift of a laser source. Experimental results indicate that the axial resolution is 0.5nm and lateral precision for grating width measurement is 0.14μm when NA=0.85 and λ=632.8nm. It can therefore be concluded that the proposed phase-shift resolving confocal microscopy can be used to achieve the high axial resolution, wide range and reflectance disturbance inhibition necessary for the measurement of microstructures made of different or hybrid material with high steps.