Evangelos-Nikolaos Madias

Mr. Evangelos-Nikolaos Madias

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Electronics
Verified
Journal Article
Open access
PDF file
George AdamGeorge Adam
George Adam
Panagiotis KontaxisPanagiotis Kontaxis
Panagiotis Kontaxis
Lambros DoulosLambros Doulos
Lambros Doulos
EMEvangelos-Nikolaos Madias
Evangelos-Nikolaos Madias
CBConstantinos A. Bouroussis
Constantinos A. Bouroussis
FTFrangiskos V. Topalis
Frangiskos V. Topalis
Although with the advent of the LEDs the energy consumption in buildings can be reduced by 50%, there exists a potential for energy savings due to lighting controls. Moreover, lighting controls can ensure that the near zero energy requirements by EU can be achieved for near zero energy buildings (nZEBs). For this reason, more sophisticated lighting controls must be proposed in order to take full advantage of LEDs and their flexibility concerning dimming. This paper proposes the architecture of an embedded computer camera controller for monitoring and management of image data, which is applied in various control cases, and particularly in digitally controlled lighting devices. The proposed system deals with real-time monitoring and management of a GigE camera input. An in-house developed algorithm using MATLAB enables the identification of areas in luminance values. The embedded microcontroller is part of a complete lighting control system with an imaging sensor in order to measure and control the illumination of several working areas of a room. The power consumption of the proposed lighting system was measured and was compared with the power consumption of a typical photosensor. The functional performance and operation of the proposed camera control system architecture was evaluated based upon a BeagleBone Black microcontroller board.

4 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
Lambros DoulosLambros Doulos
Lambros Doulos
Aris TsangrassoulisAris Tsangrassoulis
Aris Tsangrassoulis
EMEvangelos-Nikolaos Madias
Evangelos-Nikolaos Madias
Spyros NiavisSpyros Niavis
Spyros Niavis
AKAntonis Kontadakis
Antonis Kontadakis
Stelios ZerefosStelios Zerefos
Stelios Zerefos
Daylight utilization significantly contributes to energy savings in office buildings. However, daylight integration requires careful design so as to include variations in daylight availability and maintain a balance between factors such as lighting quality and heat gain or loss. Designers with proper planning can not only improve the visual environment and create higher-quality spaces, but simultaneously minimize energy costs for buildings. The utilization of photosensors can exploit the benefits of daylighting by dimming the lighting system, so that no excessive luminous flux is produced, thus leading to energy savings as well as visual contentment. However, the human factor is crucial for the proper function of a lighting control system. Without its acceptance from the users, energy savings can be minimized or even negligible. The objective of this paper is to present a post-occupancy evaluation regarding occupant satisfaction and acceptance in relation to daylighting in offices equipped with automated daylight controls. In addition, the response of the users was compared with lighting measurements that were performed during the post-occupancy evaluation. Three case studies of office buildings with installed daylight-harvesting systems were examined. The age of the occupants was a crucial factor concerning their satisfaction in relation to the lighting levels. Aged users were more comfortable with lighting levels over 500lx, while young users were satisfied with 300lx. The impact of different control algorithms was outlined, with the integral reset algorithm performing poorly. The acceptance of the users for the closed loop systems maintained the expected energy savings of the daylight harvesting technique. Most of the occupants preferred to use daylight as a light source combined with artificial light but having the control to either override or switch it on and off at will. The results shown that a post-occupancy survey along with lighting measurements are significant for making an office environment a humancentric one.

8 July 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
EMEvangelos-Nikolaos Madias
Evangelos-Nikolaos Madias
KCKonstantinos Christodoulou
Konstantinos Christodoulou
VAVasilios P. Androvitsaneas
Vasilios P. Androvitsaneas
ASAikaterini Skalkou
Aikaterini Skalkou
SSSophia Sotiropoulou
Sophia Sotiropoulou
Lambros DoulosLambros Doulos
Lambros Doulos

20 April 2019 in Operational Research
Verified
Journal Article
Closed access
PDF file
EMEvangelos-Nikolaos Madias
Evangelos-Nikolaos Madias
Lambros DoulosLambros Doulos
Lambros Doulos
Panagiotis KontaxisPanagiotis Kontaxis
Panagiotis Kontaxis
FTFrangiskos V. Topalis
Frangiskos V. Topalis

2 June 2020 in Operational Research
Verified
Journal Article
Closed access
PDF file
EMEvangelos-Nikolaos Madias
Evangelos-Nikolaos Madias
Lambros DoulosLambros Doulos
Lambros Doulos
Panagiotis KontaxisPanagiotis Kontaxis
Panagiotis Kontaxis
FTFrangiskos V. Topalis
Frangiskos V. Topalis

23 December 2024 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
MTM. Tomasovits
M. Tomasovits
Stelios ZerefosStelios Zerefos
Stelios Zerefos
ATA. Tsangrassoulis
A. Tsangrassoulis
Thanos BalafoutisThanos Balafoutis
Thanos Balafoutis
RVRebeka Vital
Rebeka Vital
Lambros DoulosLambros Doulos
Lambros Doulos