Nischal Mishra

Mr. Nischal Mishra


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2014 in Remote Sensing
Verified
Journal Article
Open access
PDF file
BMBrian Markham
Brian Markham
JBJulia Barsi
Julia Barsi
GKGeir Kvaran
Geir Kvaran
LOLawrence Ong
Lawrence Ong
EKEdward Kaita
Edward Kaita
DHDennis Helder
Dennis Helder
The Landsat-8 Operational Land Imager (OLI) was radiometrically calibrated prior to launch in terms of spectral radiance, using an integrating sphere source traceable to National Institute of Standards and Technology (NIST) standards of spectral irradiance. It was calibrated on-orbit in terms of reflectance using diffusers characterized prior to launch using NIST traceable standards. The radiance calibration was performed with an uncertainty of ~3%; the reflectance calibration to an uncertainty of ~2%. On-orbit, multiple calibration techniques indicate that the sensor has been stable to better than 0.3% to date, with the exception of the shortest wavelength band, which has degraded about 1.0%. A transfer to orbit experiment conducted using the OLI’s heliostat-illuminated diffuser suggests that some bands increased in sensitivity on transition to orbit by as much as 5%, with an uncertainty of ~2.5%. On-orbit comparisons to other instruments and vicarious calibration techniques show the radiance (without a transfer to orbit adjustment), and reflectance calibrations generally agree with other instruments and ground measurements to within the uncertainties. Calibration coefficients are provided with the data products to convert to either radiance or reflectance units.

16 December 2014 in Remote Sensing
Verified
Journal Article
Open access
PDF file
NMNischal Mishra
Nischal Mishra
MHMd Obaidul Haque
Md Obaidul Haque
LLLarry Leigh
Larry Leigh
DADavid Aaron
David Aaron
DHDennis Helder
Dennis Helder
BMBrian Markham
Brian Markham
This study evaluates the radiometric consistency between Landsat-8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+) using cross calibration techniques. Two approaches are used, one based on cross calibration between the two sensors using simultaneous image pairs, acquired during an underfly event on 29–30 March 2013. The other approach is based on using time series of image statistics acquired by these two sensors over the Libya 4 pseudo invariant calibration site (PICS) (+28.55°N, +23.39°E). Analyses from these approaches show that the reflectance calibration of OLI is generally within ±3% of the ETM+ radiance calibration for all the reflective bands from visible to short wave infrared regions when the ChKur solar spectrum is used to convert the ETM+ radiance to reflectance. Similar results are obtained comparing the OLI radiance calibration directly with the ETM+ radiance calibration and the results in these two different physical units (radiance and reflectance) agree to within ±2% for all the analogous bands. These results will also be useful to tie all the Landsat heritage sensors from Landsat 1 MultiSpectral Scanner (MSS) through Landsat-8 OLI to a consistent radiometric scale.

7 January 2015 in Remote Sensing
Verified
Journal Article
Open access
PDF file
JCJeffrey Czapla-Myers
Jeffrey Czapla-Myers
JMJoel McCorkel
Joel McCorkel
NANikolaus Anderson
Nikolaus Anderson
KTKurtis Thome
Kurtis Thome
SBStuart Biggar
Stuart Biggar
NMNischal Mishra
Nischal Mishra
This paper presents the vicarious calibration results of Landsat 8 OLI that were obtained using the reflectance-based approach at test sites in Nevada, California, Arizona, and South Dakota, USA. Additional data were obtained using the Radiometric Calibration Test Site, which is a suite of instruments located at Railroad Valley, Nevada, USA. The results for the top-of-atmosphere spectral radiance show an average difference of −2.7, −0.8, 1.5, 2.0, 0.0, 3.6, 5.8, and 0.7% in OLI bands 1–8 as compared to an average of all of the ground-based measurements. The top-of-atmosphere spectral reflectance shows an average difference of 1.6, 1.3, 2.0, 1.9, 0.9, 2.1, 3.1, and 2.1% from the ground-based measurements. Except for OLI band 7, the spectral radiance results are generally within ±5% of the design specifications, and the reflectance results are generally within ±3% of the design specifications. The results from the data collected during the tandem Landsat 7 and 8 flight in March 2013 indicate that ETM+ and OLI agree to each other to within ±2% in similar bands in top-of-atmosphere spectral radiance, and to within ±4% in top-of-atmosphere spectral reflectance.

12 February 2014 in Remote Sensing
Verified
Journal Article
Open access
PDF file
NMNischal Mishra
Nischal Mishra
DHDennis Helder
Dennis Helder
AAAmit Angal
Amit Angal
JCJason Choi
Jason Choi
XXXiaoxiong Xiong
Xiaoxiong Xiong
The objective of this paper is to report the improvements in an empirical absolute calibration model developed at South Dakota State University using Libya 4 (+28.55°, +23.39°) pseudo invariant calibration site (PICS). The approach was based on use of the Terra MODIS as the radiometer to develop an absolute calibration model for the spectral channels covered by this instrument from visible to shortwave infrared. Earth Observing One (EO-1) Hyperion, with a spectral resolution of 10 nm, was used to extend the model to cover visible and near-infrared regions. A simple Bidirectional Reflectance Distribution function (BRDF) model was generated using Terra Moderate Resolution Imaging Spectroradiometer (MODIS) observations over Libya 4 and the resulting model was validated with nadir data acquired from satellite sensors such as Aqua MODIS and Landsat 7 (L7) Enhanced Thematic Mapper (ETM+). The improvements in the absolute calibration model to account for the BRDF due to off-nadir measurements and annual variations in the atmosphere are summarized. BRDF models due to off-nadir viewing angles have been derived using the measurements from EO-1 Hyperion. In addition to L7 ETM+, measurements from other sensors such as Aqua MODIS, UK-2 Disaster Monitoring Constellation (DMC), ENVISAT Medium Resolution Imaging Spectrometer (MERIS) and Operational Land Imager (OLI) onboard Landsat 8 (L8), which was launched in February 2013, were employed to validate the model. These satellite sensors differ in terms of the width of their spectral bandpasses, overpass time, off-nadir-viewing capabilities, spatial resolution and temporal revisit time, etc. The results demonstrate that the proposed empirical calibration model has accuracy of the order of 3% with an uncertainty of about 2% for the sensors used in the study.

1 November 2016 in Remote Sensing of Environment
Verified
Journal Article
Closed access
NMNischal Mishra
Nischal Mishra
DHDennis Helder
Dennis Helder
JBJulia Barsi
Julia Barsi
BMBrian Markham
Brian Markham

31 December 2014 in Remote Sensing
Verified
Journal Article
Open access
PDF file
FPFrank Pesta
Frank Pesta
SBSuman Bhatta
Suman Bhatta
DHDennis Helder
Dennis Helder
NMNischal Mishra
Nischal Mishra
Landsat 8 is the first satellite in the Landsat mission to acquire spectral imagery of the Earth using pushbroom sensor instruments. As a result, there are almost 70,000 unique detectors on the Operational Land Imager (OLI) alone to monitor. Due to minute variations in manufacturing and temporal degradation, every detector will exhibit a different behavior when exposed to uniform radiance, causing a noticeable striping artifact in collected imagery. Solar collects using the OLI’s on-board solar diffuser panels are the primary method of characterizing detector level non-uniformity. This paper reports on an approach for using a side-slither maneuver to estimate relative detector gains within each individual focal plane module (FPM) in the OLI. A method to characterize cirrus band detector-level non-uniformity using deep convective clouds (DCCs) is also presented. These approaches are discussed, and then, correction results are compared with the diffuser-based method. Detector relative gain stability is assessed using the side-slither technique. Side-slither relative gains were found to correct streaking in test imagery with quality comparable to diffuser-based gains (within 0.005% for VNIR/PAN; 0.01% for SWIR) and identified a 0.5% temporal drift over a year. The DCC technique provided relative gains that visually decreased striping over the operational calibration in many images.