As passive rehabilitation training with fixed trajectory ignores the active participation of patients, in order to increase the active participation of patients and improve the effect of rehabilitation training, this paper proposes an innovative adaptive sliding mode variable admittance (ASMVA) controller for the Lower Limb Rehabilitation Exoskeleton Robot. The ASMVA controller consists of an outer loop with variable admittance controller and an inner loop with an adaptive sliding mode controller. It estimates the wearer’s active muscle strength and movement intention by judging the deviation between the actual and standard interaction force of the wearer’s leg and the exoskeleton, thereby adaptively changing admittance controller parameters to alter training intensity. Three healthy volunteers engaged in further experimental studies, including trajectory tracking experiments with no admittance, fixed admittance, and variable admittance adjustment. The experimental results show that the proposed ASMVA control scheme has high control accuracy. Besides, the ASMVA can not only increase training intensity according to the active muscle strength of the patient during positive movement intention (so as to increase active participation of the patient), but also increase the amount of trajectory adjustment during negative movement intention to ensure the safety of the patient.
The surface electromyography (sEMG) signal has been used for volitional control of robotic assistive devices. There are still challenges in improving system performance accuracy and signal processing to remove systematic noise. This study presents procedures and a pilot validation of the EMG-driven speed-control of exoskeleton and integrated treadmill with a goal to provide better interaction between a user and the system. The gait cycle duration (GCD) was extracted from sEMG signals using the autocorrelation algorithm and Bayesian fusion algorithm. GCDs of various walking speeds were then programmed to control the motion speed of exoskeleton robotic system. The performance and efficiency of this sEMG-controlled robotic assistive ambulation system was tested and validated among 6 healthy volunteers. The results demonstrated that the autocorrelation algorithm extracted the GCD from individual muscle contraction. The GCDs of individual muscles had variability between different walking steps under a designated walking speed. Bayesian fusion algorithms processed the GCDs of multiple muscles yielding a final GCD with the least variance. The fused GCD effectively controlled the motion speeds of exoskeleton and treadmill. The higher amplitude of EMG signals with shorter GCD was found during a faster walking speed. The algorithms using fused GCDs and gait stride length yielded trajectory joint motion tracks in a shape of sine curve waveform. The joint angles of the exoskeleton measured by a decoder mounted on the hip turned out to be in sine waveforms. The hip joint motion track of the exoskeleton matched the angles projected by trajectory curve generated by computer algorithms based on the fused GCDs with high agreement. The EMG-driven speed-control provided the human-machine inter-limb coordination mechanisms for an intuitive speed control of the exoskeleton-treadmill system at the user’s intents. Potentially the whole system can be used for gait rehabilitation of incomplete spinal cord hemispheric stroke patients as goal-directed and task-oriented training tool.
A nanoscale representative volume element has been developed to investigate the effect of interphase geometry and property on the mechanical behavior of silica/epoxy resin nanocomposites. The role of interphase–matrix bonding was also examined. Results suggested that interphase modulus and interfacial bonding conditions had significant influence on the effective stiffness of nanocomposites, while its sensitivities with respect to both the thickness and the gradient property of the interphase was minimal. The stiffer interphase demonstrated a higher load-sharing capacity, which also increased the stress distribution uniformity within the resin nanocomposites. Under the condition of imperfect interfacial bonding, the effective stiffness of nanocomposites was much lower, which was in good agreement with the documented experimental observations. This work could shed some light on the design and manufacturing of resin nanocomposites.
In response to the need for an exoskeleton to quickly identify the wearer’s movement mode in the mixed control mode, this paper studies the impact of different feature parameters of the surface electromyography (sEMG) signal on the accuracy of human motion pattern recognition using multilayer perceptrons and long short-term memory (LSTM) neural networks. The sEMG signals are extracted from the seven common human motion patterns in daily life, and the time domain and frequency domain features are extracted to build a feature parameter dataset for training the classifier. Recognition of human lower extremity movement patterns based on multilayer perceptrons and the LSTM neural network were carried out, and the final recognition accuracy rates of different feature parameters and different classifier model parameters were compared in the process of establishing the dataset. The experimental results show that the best accuracy rate of human motion pattern recognition using multilayer perceptrons is 95.53%, and the best accuracy rate of human motion pattern recognition using the LSTM neural network is 96.57%.
The estimation of multijoint angles is of great significance in the fields of lower limb rehabilitation, motion control, and exoskeleton robotics. Accurate joint angle estimation helps assess joint function, assist in rehabilitation training, and optimize robotic control strategies. However, estimating multijoint angles in different movement patterns, such as walking, obstacle crossing, squatting, and knee flexion–extension, using surface electromyography (sEMG) signals remains a challenge. In this study, a model is proposed for the continuous motion estimation of multijoint angles in the lower limb (CB-TCN: temporal convolutional network + convolutional block attention module + temporal convolutional network). The model integrates temporal convolutional networks (TCNs) with convolutional block attention modules (CBAMs) to enhance feature extraction and improve prediction accuracy. The model effectively captures temporal features in lower limb movements, while enhancing attention to key features through the attention mechanism of CBAM. To enhance the model’s generalization ability, this study adopts a sliding window data augmentation method to expand the training samples and improve the model’s adaptability to different movement patterns. Through experimental validation on 8 subjects across four typical lower limb movements, walking, obstacle crossing, squatting, and knee flexion–extension, the results show that the CB-TCN model outperforms traditional models in terms of accuracy and robustness. Specifically, the model achieved R2 values of up to 0.9718, RMSE as low as 1.2648°, and NRMSE values as low as 0.05234 for knee angle prediction during walking. These findings indicate that the model combining TCN and CBAM has significant advantages in predicting lower limb joint angles. The proposed approach shows great promise for enhancing lower limb rehabilitation and motion analysis.