Ismail Laarossi

Mr. Ismail Laarossi

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ILIsmail Laarossi
Ismail Laarossi
MQMaría Ángeles Quintela-Incera
María Ángeles Quintela-Incera
Jose Lopez-HigueraJose Lopez-Higuera
Jose Lopez-Higuera
An experimental study of a high temperature distributed optical fiber sensor based on Raman Optical-Time-Domain-Reflectometry (ROTDR) (up to 450 °C) and optical fibers with different coatings (polyimide/carbon, copper, aluminum and gold) is presented. Analysis of the distributed temperature sensor (DTS) measurements determined the most appropriate optical fiber to be used in high temperature industrial environment over long periods of time. To demonstrate the feasibility of this DTS for an industrial application, an optical cable was designed with the appropriate optical fiber and it was hermetically sealed to provide the required mechanical resistance and isolate the fiber from environmental degradations. This cable was used to measure temperature up to 360 °C of an industrial furnace during 7 days.

1 December 2016 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Open access
ILIsmail Laarossi
Ismail Laarossi
RLRuben Ruiz Lombera
Ruben Ruiz Lombera
MQMaria Angeles Quintela
Maria Angeles Quintela
JMJesus Mirapeix
Jesus Mirapeix
DLDomingo Lima
Domingo Lima
Jose Lopez-HigueraJose Lopez-Higuera
Jose Lopez-Higuera
An ultrahigh temperature distributed sensor based on a Raman optical-time-domain-reflectometry (ROTDR) and two types of fibers: a standard multimode fiber and multimode gold-coated fiber are experimentally validated in this paper. A calibration technique has been implemented to correct the dynamic variation of the optical loss in the gold-coated fiber. Distributed temperature measurements up to 600̊ C have been carried out.

13 February 2017 in IEEE Sensors Journal
Verified
Journal Article
Open access
RRRuben Ruiz-Lombera
Ruben Ruiz-Lombera
ILIsmail Laarossi
Ismail Laarossi
LRLuis Rodriguez-Cobo
Luis Rodriguez-Cobo
MQMaria Angeles Quintela
Maria Angeles Quintela
Jose Lopez-HigueraJose Lopez-Higuera
Jose Lopez-Higuera
JMJesus Mirapeix
Jesus Mirapeix
A high-temperature distributed sensor system based on a Brillouin optical time-domain analyzer and a multimode gold-coated fiber is presented in this paper. Distributed measurements of temperatures up to 600 °C are demonstrated with a temperature accuracy of about 10 °C. The system shows a consistent response for repetitive measurements, even considering increasing or decreasing temperature changes. This is the first time to the best of our knowledge that a gold-coated fiber is used for high-temperature distributed measurements in a Brillouin-based system. The proposed solution via the gold-coated fiber allows a feasible deployment in field applications such as industrial scenarios.

9 December 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
ILIsmail Laarossi
Ismail Laarossi
PRPablo Roldán-Varona
Pablo Roldán-Varona
MQM. A. Quintela-Incera
M. A. Quintela-Incera
LRL. Rodríguez-Cobo
L. Rodríguez-Cobo
Jose Lopez-HigueraJose Lopez-Higuera
Jose Lopez-Higuera
In this paper, a novel approach for hybrid systems combining Raman distributed sensors with fiber Bragg grating (FBG) sensors to carry out distributed and quasi-distributed temperature/strain measurements was proposed and experimentally demonstrated. Three FBGs were inscribed by the point-by-point technique in a simple setup for type I femtosecond inscription in a pure silica core multimode gold-coated fiber. Employing a single fiber, temperatures up to 600 °C and strains up to 4144 μɛ approximately were measured simultaneously and without interferences between both distributed and point measurements. Moreover, a new calibration technique was implemented to calibrate the distributed temperature system using the FBG measurements as reference.

13 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
NCNeus Revert Calabuig
Neus Revert Calabuig
ILIsmail Laarossi
Ismail Laarossi
AGAntonio Álvarez González
Antonio Álvarez González
ANAlejandro Pérez Núñez
Alejandro Pérez Núñez
LPLaura González Pérez
Laura González Pérez
ACAbraham Casas
Abraham Casas
A low-cost smart sensor GNSS system has been developed to provide accurate real-time position and orientation measurements on a floating offshore wind platform. The approach chosen to offer a viable and reliable solution for this application is based on the use of the well-known advantages of the GNSS system as the main driver for enhancing the accuracy of positioning. For this purpose, the data reported in this work are captured through a GNSS receiver operating over multiple frequency bands (L1, L2, L5) and combining signals from different constellations of navigation satellites (GPS, Galileo, and GLONASS), and they are processed through the precise point positioning (PPP) and real-time kinematic (RTK) techniques. Furthermore, aiming to improve global positioning, the processing unit fuses the results obtained with the data acquired through an inertial measurement unit (IMU), reaching final accuracy of a few centimeters. To validate the system designed and developed in this proposal, three different sets of tests were carried out in a (i) rotary table at the laboratory, (ii) GNSS simulator, and (iii) real conditions in an oceanic buoy at sea. The real-time positioning solution was compared to solutions obtained by post-processing techniques in these three scenarios and similar results were satisfactorily achieved.

30 May 2016
Verified
Conference Paper
Open access
PDF file
RLRuben Ruiz Lombera
Ruben Ruiz Lombera
JMJesus Mirapeix
Jesus Mirapeix
ILIsmail Laarossi
Ismail Laarossi
LRL. Rodríguez-Cobo
L. Rodríguez-Cobo
Jose Lopez-HigueraJose Lopez-Higuera
Jose Lopez-Higuera
In this paper we propose the employment of sub-pixel algorithms for the estimation of the central frequency of the Brillouin Gain Spectrum in a Brillouin Optical Time Domain Analyzer. The experimental results will show that the proposed solution shows a good performance when the chosen frequency step for the required frequency sweep is high. If the improved computational efficiency in comparison to the traditional Lorentzian fitting is also considered, it can be concluded that this approach may be of great interest for dynamic measurement scenarios.This work has been supported by the Universidad de Cantabria and by the Spanish Ministerio de Ciencia e Innovación through project TEC2013-47264-C2-1-R