Guolin Li

Dr. Guolin Li


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2020 in Microwave and Optical Technology Letters
Verified
Journal Article
Closed access
PDF file
GLGuolin Li
Guolin Li
KMKun Ma
Kun Ma
YJYue Jiao
Yue Jiao
QJQingzhi Jiang
Qingzhi Jiang
XZXuena Zhang
Xuena Zhang
DSDi Song
Di Song

22 April 2023 in Infrared Physics & Technology
Verified
Journal Article
Closed access
GLGuolin Li
Guolin Li
YSYimeng Song
Yimeng Song
HZHao Zhao
Hao Zhao
EDEnting Dong
Enting Dong
JLJiarui Li
Jiarui Li
FZFuli Zhao
Fuli Zhao

23 August 2022 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
GLGuolin Li
Guolin Li
YWYunhui Wu
Yunhui Wu
ZZZecheng Zhang
Zecheng Zhang
XZXuena Zhang
Xuena Zhang
KMKun Ma
Kun Ma
QLQiang Li
Qiang Li

6 January 2023 in Measurement
Verified
Journal Article
Closed access
GLGuolin Li
Guolin Li
XZXuena Zhang
Xuena Zhang
ZZZecheng Zhang
Zecheng Zhang
YWYunhui Wu
Yunhui Wu
HZHao Zhao
Hao Zhao
SZShenqiang Zhai
Shenqiang Zhai

9 December 2024 in Photoacoustics
Verified
Journal Article
Open access
Weilin YeWeilin Ye
Weilin Ye
LHLinfeng He
Linfeng He
WLWeihao Liu
Weihao Liu
ZYZhile Yuan
Zhile Yuan
KZKaiyuan Zheng
Kaiyuan Zheng
GLGuolin Li
Guolin Li
Traditional beat frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) are limited by short energy accumulation times and the necessity of a decay period, leading to weaker signals and longer measurement cycles. Herein, we present a novel optomechanical energy-enhanced (OEE-) BF-QEPAS technique for fast and sensitive gas sensing. Our approach employs periodic pulse-width modulation (PWM) of the laser signal with an optimized duty cycle, maintaining the quartz tuning fork's (QTF) output at a stable steady-state level by applying stimulus signals at each half-period and allowing free vibration in alternate half-periods to minimize energy dissipation. This method enhances optomechanical energy accumulation in the QTF, resulting in an approximate 33-fold increase in response speed and a threefold increase in signal intensity compared to conventional BF-QEPAS. We introduce an energy efficiency coefficient K to quantify the relationship between transient signal amplitude and measurement duration, exploring its dependence on the modulation signal's period and duty cycle. Theoretical analyses and numerical simulations demonstrate that the maximum K occurs at a duty cycle of 50 % and an optimized beat frequency Δf of 30 Hz. Experimental results using methane reveal a detection limit of 2.17 ppm with a rapid response time of 33 ms. The OEE-BF-QEPAS technique exhibits a wide dynamic range with exceptional linearity over five orders of magnitude and a record noise-equivalent normalized absorption (NNEA) coefficient of 9.46 × 10−10 W cm−1 Hz−1/2. Additionally, a self-calibration method is proposed for correcting resonant frequency shifts. The proposed method holds immense potential for applications requiring fast and precise gas detection.

26 November 2019 in Frontiers in Physics
Verified
Journal Article
Open access
PDF file
GLGuolin Li
Guolin Li
EDEnting Dong
Enting Dong
WJWen-Hai Ji
Wen-Hai Ji
A near-infrared trace CO2 detection system was experimentally demonstrated based on an 1,580 nm distributed feedback (DFB) laser using a cascaded integrator comb (CIC) filter-assisted wavelength modulation spectroscopy (WMS) technique and a digital lock-in amplifier (DLIA). An 1,580 nm DFB laser emitting at 1,579.1 nm was selected as the light source. A multi-pass cell (MPGC with a 30 m- long path) was adopted as the absorption cell. A DLIA was developed to extract the second harmonic WMS (WMS-2f) signal. The cascade-integrated comb filter (CICF) and the finite impulse response (FIR) low-pass filter (LPF) were combined in the DLIA to improve the performance of DLIA. Three methods of PD (Peak detection), LIA, CICF-assisted WMS, and DLIA were adopted to detect the CO2 concentration levels and the anti-interference performance of each detection method was analyzed. The experimental results indicated that compared with the peak detection and the lock-in amplifier method of the CICF-assisted WMS and DLIA developed in this manuscript had the highest linearity and precision. When the integration time is 3s, the LOD of the system was predicted to be 0.0812 ppm. Due to the advantages of high sensitivity, a low detection limit and a rapid response, the CO2 detection system reported in this manuscript has a good application prospect in the area of oilfield associated gases detection.