Kaiyuan Zheng

Dr. Kaiyuan Zheng


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2024 in Photoacoustics
Verified
Journal Article
Open access
Weilin YeWeilin Ye
Weilin Ye
LHLinfeng He
Linfeng He
WLWeihao Liu
Weihao Liu
ZYZhile Yuan
Zhile Yuan
KZKaiyuan Zheng
Kaiyuan Zheng
GLGuolin Li
Guolin Li
Traditional beat frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) are limited by short energy accumulation times and the necessity of a decay period, leading to weaker signals and longer measurement cycles. Herein, we present a novel optomechanical energy-enhanced (OEE-) BF-QEPAS technique for fast and sensitive gas sensing. Our approach employs periodic pulse-width modulation (PWM) of the laser signal with an optimized duty cycle, maintaining the quartz tuning fork's (QTF) output at a stable steady-state level by applying stimulus signals at each half-period and allowing free vibration in alternate half-periods to minimize energy dissipation. This method enhances optomechanical energy accumulation in the QTF, resulting in an approximate 33-fold increase in response speed and a threefold increase in signal intensity compared to conventional BF-QEPAS. We introduce an energy efficiency coefficient K to quantify the relationship between transient signal amplitude and measurement duration, exploring its dependence on the modulation signal's period and duty cycle. Theoretical analyses and numerical simulations demonstrate that the maximum K occurs at a duty cycle of 50 % and an optimized beat frequency Δf of 30 Hz. Experimental results using methane reveal a detection limit of 2.17 ppm with a rapid response time of 33 ms. The OEE-BF-QEPAS technique exhibits a wide dynamic range with exceptional linearity over five orders of magnitude and a record noise-equivalent normalized absorption (NNEA) coefficient of 9.46 × 10−10 W cm−1 Hz−1/2. Additionally, a self-calibration method is proposed for correcting resonant frequency shifts. The proposed method holds immense potential for applications requiring fast and precise gas detection.

27 August 2025 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
ZPZihang Peng
Zihang Peng
YMYuting Min
Yuting Min
MPMingquan Pi
Mingquan Pi
KZKaiyuan Zheng
Kaiyuan Zheng
FSFang Song
Fang Song
Chuantao ZhengChuantao Zheng
Chuantao Zheng
This study proposes to employ slow light-enhanced mode multiplexing in infrared absorption spectroscopy for on-chip multi-gas detection. The 1D PCW generates a slow odd mode within the 1520–1555 nm range, and a slow even mode within 1615–1665 nm.