De-Ning Pei

Prof. De-Ning Pei


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2024 in Human Gene Therapy
Verified
Journal Article
Closed access
XQXi Qin
Xi Qin
QYQikun Yu
Qikun Yu
XLXiang Li
Xiang Li
WJWei Jiang
Wei Jiang
XSXinchang Shi
Xinchang Shi
CLChenggang Liang
Chenggang Liang
Currently, adeno-associated virus (AAV) is one of the primary gene delivery vectors in gene therapy, facilitating long-term in vivo gene expression. Despite being imperative, it is incredibly challenging to precisely assess AAV particle distribution according to the sedimentation coefficient and identify impurities related to capsid structures. This study performed the systematic methodological validation of quantifying the AAV empty and full capsid ratio. This includes specificity, accuracy, precision, linearity, and parameter variables involving the sedimentation velocity analytical ultracentrifugation (SV-AUC) method. Specifically, SV-AUC differentiated among the empty, partial, full, and high sedimentation coefficient substance (HSCS) AAV particles while evaluating their sedimentation heterogeneity. The intermediate precision analysis of HE (high percentage of empty capsid) and HF (high percentage of full capsid) samples revealed that the specific species percentage, such as empty or full, was more significant than 50%. Moreover, the relative standard deviation (RSD) could be within 5%. Even for empty or partially less than 15%, the RSD could be within 10%. The accuracy recovery rates of empty capsid were between 103.9% and 108.7% across three different mixtures. When the measured percentage of specific species was more significant than 14%, the recovery rate was between 77.9% and 106.6%. Linearity analysis revealed an excellent linear correlation between the empty, partial, and full in the HE samples. The AAV samples with as low as 7.4 × 10 11 cp/mL AAV could be accurately quantified with SV-AUC. The parameter variable analyses revealed that variations in cell alignment significantly affected the overall results. Still, the detection wavelength of 235 nm slightly influenced the empty, partial, and full percentages. Minor detection wavelength changes showed no impact on the sedimentation coefficient of these species. However, the temperature affected the measured sedimentation coefficient. These results validated the SV-AUC method to quantify AAV. This study provides solutions to AAV empty and full capsid ratio quantification challenges and the subsequent basis for calibrating the AAV empty capsid system suitability substance. Because of the AAV structure and potential variability complexity in detection, we jointly calibrated empty capsid system suitability substance with three laboratories to accurately detect the quantitative AAV empty and full capsid ratio. The empty capsid system suitability substance could be used as an external reference to measure the performance of the instrument. The results could be compared with multiple QC (quality control) laboratories based on the AAV vector and calibration accuracy. This is crucial for AUC to be used for QC release and promote gene therapy research worldwide.

25 October 2019 in Molecules
Verified
Journal Article
Open access
PDF file
LYLei Yu
Lei Yu
CJChuncui Jia
Chuncui Jia
WYWenrong Yao
Wenrong Yao
DPDe-Ning Pei
De-Ning Pei
XQXi Qin
Xi Qin
JWJun-Zhi Wang
Jun-Zhi Wang
Soluble glycoprotein 130 kDa (sgp130)-Fc fusion protein, an innovative therapeutic bio-macromolecular drug specifically targeting IL-6 trans-signaling, proved to have good potential for application in the treatment of chronic inflammatory diseases. A simple and quick bioassay for sgp130-Fc was developed in this study. First, a stable reporter cell line was obtained by transfecting CHO-K1 cells with a sis-inducible element (SIE)-driving luciferase reporter gene (CHO/SIE-Luc). Sgp130-Fc could inhibit the expression of luciferase induced by IL-6/sIL-6Rα complex, and the dose–response curve fitted the four-parameter logistic model, with 50% inhibitive concentration (IC50) being about 500 ng/mL and detection range between 40 and 5000 ng/mL. Both the intra-assay and inter-assay coefficient of variation (CV) were below 10.0%, and the accuracy estimates ranged from 94.1% to 106.2%. The assay indicated a good linearity (R² = 0.99) in the range of 50% to 150% of optimized initial concentration. No significant difference was found between the test results of new assay and BAF3/gp130 proliferation assay (unpaired t test, p = 0.4960, n = 6). The dose-response effect and copy number of the luciferase gene was basically unchanged after long-term culture (up to passage 60), demonstrating the stability of CHO/SIE-Luc cells. These results suggested that the new reporter assay was suited to routine potency determination of therapeutic sgp130-Fc.

15 May 2025 in Molecules
Verified
Journal Article
Open access
PDF file
DPDe-Ning Pei
De-Ning Pei
XLXiang Li
Xiang Li
HBHua Bi
Hua Bi
WFWenhong Fan
Wenhong Fan
HWHeng Wang
Heng Wang
CLChenggang Liang
Chenggang Liang
Adeno-associated virus (AAV) is a promising gene therapy vector due to its high transduction efficiency, low pathogenicity, low immunogenicity, and the ability to mediate the long-term stable expression of exogenous genes. The viral particle titer is an essential quality attribute of recombinant adeno-associated virus (rAAV) gene therapy products. Multiangle light scattering (MALS) is an important means of directly measuring the absolute molecular weight and distribution of macromolecular drugs. This study established and validated a method based on SEC-UV-MALS-RI tandem technology for accurately determining rAAV particle titers. The verification results indicated that the method exhibited good specificity, linearity, precision, accuracy, and durability. Several collaborative laboratories used this method to calibrate the standard substances needed for rAAV particle titer determination. The results suggested that combining the SEC-MALS method with standard substances enables the rapid and accurate measurement of the viral particle titers in rAAV gene therapy products.

31 August 2020 in Molecules
Verified
Journal Article
Open access
PDF file
LYLei Yu
Lei Yu
LTLei Tao
Lei Tao
YZYinghua Zhao
Yinghua Zhao
YLYonghong Li
Yonghong Li
DPDe-Ning Pei
De-Ning Pei
CRChunming Rao
Chunming Rao
Recombinant human IFNα2b (rhIFNα2b), as an important immune-related protein, has been widely used in clinic for decades. It is also at the forefront of the recent emergence of biosimilar medicines, with numerous products now available worldwide. Although with the same amino acid sequence, recombinant proteins are generally heterogeneous due to post-translational modification and chemical reactions during expression, purification, and long-term storage, which could have significant impact on the final product quality. So therapeutic rhIFNα2b must be closely monitored to ensure consistency, safety, and efficacy. In this study, we compared seven rhIFNα2b preparations from six manufacturers in China and one in America, as well as four batches of rhIFNα2b preparations from the same manufacturer, measuring IFNα2b variants and site-specific modifications using a developed LC/Q-TOF approach. Three main forms of N-terminus, cysteine, methionine, and acetylated cysteine were detected in five rhIFNα2b preparations produced in E. coli (1E~5E) and one in Pseudomonas (6P), but only the native form with N-terminal cysteine was found in rhIFNα2b preparation produced in Saccharomyces cerevisiae (7Y). Two samples with the lowest purity (4E and 6P), showed the highest level of acetylation at N-terminal cysteine and oxidation at methionine. The level of oxidation and deamidation varied not only between samples from different manufacturers but also between different batches of the same manufacturer. Although variable between samples from different manufacturers, the constitution of N-terminus and disulfide bonds was relatively stable between different batches, which may be a potential indicator for batch consistency. These findings provide a valid reference for the stability evaluation of the production process and final products.

17 October 2025 in Biophysica
Verified
Journal Article
Open access
PDF file
QMQiang Ma
Qiang Ma
LZLiuqiang Zhu
Liuqiang Zhu
XLXiang Li
Xiang Li
DPDe-Ning Pei
De-Ning Pei
LYLei Yu
Lei Yu
JWJun-Zhi Wang
Jun-Zhi Wang
Human granulocyte colony-stimulating factor (hG-CSF) is primarily used to treat neutropenia induced by cancer chemotherapy and bone marrow transplantation. The current identification test for hG-CSF relies on Western blot (WB), a labor-intensive and technically demanding method. This study aimed to screen and prepare an anti-hG-CSF nanobody to identify and quantify hG-CSF, with the ultimate goal of developing colloidal gold-labeled nanobody test strips for rapid identification. An alpaca was immunized with hG-CSF, and the VHH gene sequence encoding the anti-hG-CSF nanobody was obtained through sequencing following phage display library construction and multiple rounds of biopanning. The nanobody C68, obtained from screening, was expressed by E. coli, and its physicochemical properties such as molecular weight, isoelectric point, and affinity were characterized after purification. WB analysis demonstrated excellent performance of the nanobody in identification tests in terms of specificity, limit of detection (LOD), applicability with products from various manufacturers, and thermal stability. Additionally, we established an ELISA method for hG-CSF quantification utilizing the nanobody C68 and conducted methodological validation. Finally, colloidal gold-based test strips were constructed using the nanobody C68, with a LOD of 30 μg/mL, achieving rapid identification for hG-CSF. This study represents a novel application of nanobodies in pharmaceutical testing and offers valuable insights for developing identification tests for other recombinant protein drugs.

23 May 2026 in Molecules
Verified
Journal Article
Open access
PDF file
YGYing Guo
Ying Guo
XQXi Qin
Xi Qin
JZJing Zhang
Jing Zhang
HBHua Bi
Hua Bi
SHShuting Hou
Shuting Hou
CLChenggang Liang
Chenggang Liang
Currently, the most commonly used methods for detecting Mycoplasma are the culture method and the indicator cell culture method. However, both approaches exhibit low sensitivity and are incapable of detecting low-concentration contamination. In addition, the detection period may extend up to 28 days, which is unsuitable for rapid screening and may delay timely contamination control measures. To address these limitations, a Mycoplasma detection method based on nucleic acid amplification technology (NAT) was developed following a comparative analysis of gene sequences from various Mycoplasma species. The method was validated with respect to its detection performance and its applicability to biological product samples. DNA was extracted from Mycoplasma-contaminated samples using a magnetic bead-based nucleic acid extraction method. Universal primers were designed based on the highly conserved 16S rRNA gene sequence of Mycoplasma, and amplification was performed using multiplex quantitative PCR (qPCR) with fluorescent probes. The limit of detection (LOD) was established based on statistics of 24 replicates. Method specificity and robustness were evaluated according to the guidelines set by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH Q2), while sample applicability was assessed in accordance with the European Pharmacopoeia (EP) . The NAT-based Mycoplasma detection method enabled rapid, qualitative identification of Mycoplasma contamination. The validated LOD was 10 CFU/mL, and the method met predefined requirements for sensitivity, specificity, and robustness. To assess applicability, real biological product samples, including monoclonal antibodies, antibody fusion proteins, bispecific antibodies, and trispecific antibodies, were spiked with 10 CFU/mL of standard Mycoplasma strains. All spiked samples tested positive. These findings confirm that the NAT-based Mycoplasma detection method is suitable for process control and product release testing in the production of biological products.