Michael Höft

Dr. Michael Höft

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AKAnne Kittmann
Anne Kittmann
PDPhillip Durdaut
Phillip Durdaut
SZSebastian Zabel
Sebastian Zabel
JRJens Reermann
Jens Reermann
JSJulius Schmalz
Julius Schmalz
Eckhard QuandtEckhard Quandt
Eckhard Quandt
We present a comprehensive study of a magnetic sensor system that benefits from a new technique to substantially increase the magnetoelastic coupling of surface acoustic waves (SAW). The device uses shear horizontal acoustic surface waves that are guided by a fused silica layer with an amorphous magnetostrictive FeCoSiB thin film on top. The velocity of these so-called Love waves follows the magnetoelastically-induced changes of the shear modulus according to the magnetic field present. The SAW sensor is operated in a delay line configuration at approximately 150 MHz and translates the magnetic field to a time delay and a related phase shift. The fundamentals of this sensor concept are motivated by magnetic and mechanical simulations. They are experimentally verified using customized low-noise readout electronics. With an extremely low magnetic noise level of ≈100 pT/ $$\sqrt{{\rm{Hz}}}$$ Hz , a bandwidth of 50 kHz and a dynamic range of 120 dB, this magnetic field sensor system shows outstanding characteristics. A range of additional measures to further increase the sensitivity are investigated with simulations.

11 July 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
EYE. Yarar
E. Yarar
SSS. Salzer
S. Salzer
VHV. Hrkac
V. Hrkac
APA. Piorra
A. Piorra
MHMichael Höft
Michael Höft
Eckhard QuandtEckhard Quandt
Eckhard Quandt
Prior investigations on magnetoelectric (ME) thin film sensors using amorphous FeCoSiB as a magnetostrictive layer and AlN as a piezoelectric layer revealed a limit of detection (LOD) in the range of a few pT/Hz1/2 in the mechanical resonance. These sensors are comprised of a Si/SiO2/Pt/AlN/FeCoSiB layer stack, as dictated by the temperatures required for the deposition of the layers. A low temperature deposition route of very high quality AlN allows the reversal of the deposition sequence, thus allowing the amorphous FeCoSiB to be deposited on the very smooth Si substrate. As a consequence, the LOD could be enhanced by almost an order of magnitude reaching 400 fT/Hz1/2 at the mechanical resonance of the sensor. Giant ME coefficients (αME) as high as 5 kV/cm Oe were measured. Transmission electron microscopy investigations revealed highly c-axis oriented growth of the AlN starting from the Pt-AlN interface with local epitaxy.

1 February 2018 in Measurement
Verified
Journal Article
Closed access
JRJens Reermann
Jens Reermann
PDPhillip Durdaut
Phillip Durdaut
SSSebastian Salzer
Sebastian Salzer
TDThomas Demming
Thomas Demming
APAndré Piorra
André Piorra
GSGerhard Schmidt
Gerhard Schmidt

2 May 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
PHP. Hayes
P. Hayes
SSS. Salzer
S. Salzer
JRJ. Reermann
J. Reermann
EYE. Yarar
E. Yarar
VRV. Röbisch
V. Röbisch
Eckhard QuandtEckhard Quandt
Eckhard Quandt
Magnetoelectric thin film composites have demonstrated their potential to detect sub-pT magnetic fields if mechanical resonances (typically few hundred Hz to a few kHz) are utilized. At low frequencies (1–100 Hz), magnetic field-induced frequency conversion has enabled wideband measurements with resonance-enhanced sensitivities by using the nonlinear characteristics of the magnetostriction curve. Nevertheless, the modulation with a magnetic field with a frequency close to the mechanical resonance results in a number of drawbacks, which are, e.g., size and energy consumption of the sensor as well as potential crosstalk in sensor arrays. In this work, we demonstrate the feasibility of an electric frequency conversion of a magnetoelectric sensor which would overcome the drawbacks of magnetic frequency conversion. This magnetoelectric sensor consists of three functional layers: an exchange biased magnetostrictive multilayer showing a high piezomagnetic coefficient without applying a magnetic bias field, a non-linear piezoelectric actuation layer and a linear piezoelectric sensing layer. In this approach, the low frequency magnetic signal is shifted into the mechanical resonance of the sensor, while the electric modulation frequency is chosen to be either the difference or the sum of the resonance and the signal frequency. Using this electric frequency conversion, a limit of detection in the low nT/Hz1/2 range was shown for signals of low frequency.

28 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
EEEric Elzenheimer
Eric Elzenheimer
CBChristin Bald
Christin Bald
EEErik Engelhardt
Erik Engelhardt
JHJohannes Hoffmann
Johannes Hoffmann
PHPatrick Hayes
Patrick Hayes
Gerhard SchmidtGerhard Schmidt
Gerhard Schmidt
Dedicated research is currently being conducted on novel thin film magnetoelectric (ME) sensor concepts for medical applications. These concepts enable a contactless magnetic signal acquisition in the presence of large interference fields such as the magnetic field of the Earth and are operational at room temperature. As more and more different ME sensor concepts are accessible to medical applications, the need for comparative quality metrics significantly arises. For a medical application, both the specification of the sensor itself and the specification of the readout scheme must be considered. Therefore, from a medical user’s perspective, a system consideration is better suited to specific quantitative measures that consider the sensor readout scheme as well. The corresponding sensor system evaluation should be performed in reproducible measurement conditions (e.g., magnetically, electrically and acoustically shielded environment). Within this contribution, an ME sensor system evaluation scheme will be described and discussed. The quantitative measures will be determined exemplarily for two ME sensors: a resonant ME sensor and an electrically modulated ME sensor. In addition, an application-related signal evaluation scheme will be introduced and exemplified for cardiovascular application. The utilized prototype signal is based on a magnetocardiogram (MCG), which was recorded with a superconducting quantum-interference device. As a potential figure of merit for a quantitative signal assessment, an application specific capacity (ASC) is introduced. In conclusion, this contribution highlights metrics for the quantitative characterization of ME sensor systems and their resulting output signals in biomagnetism. Finally, different ASC values and signal-to-noise ratios (SNRs) could be clearly presented for the resonant ME sensor (SNR: −90 dB, ASC: 9.8×10−7 dB Hz) and also the electrically modulated ME sensor (SNR: −11 dB, ASC: 23 dB Hz), showing that the electrically modulated ME sensor is better suited for a possible MCG application under ideal conditions. The presented approach is transferable to other magnetic sensors and applications.

8 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PHP. Hayes
P. Hayes
Matic Jovičević-KlugMatic Jovičević-Klug
Matic Jovičević-Klug
STS. Toxværd
S. Toxværd
PDP. Durdaut
P. Durdaut
VSV. Schell
V. Schell
Eckhard QuandtEckhard Quandt
Eckhard Quandt
Magnetoelectric (ME) thin film composites consisting of sputtered piezoelectric (PE) and magnetostrictive (MS) layers enable for measurements of magnetic fields passively, i.e. an AC magnetic field directly generates an ME voltage by mechanical coupling of the MS deformation to the PE phase. In order to achieve high field sensitivities a magnetic bias field is necessary to operate at the maximum piezomagnetic coefficient of the MS phase, harnessing mechanical resonances further enhances this direct ME effect size. Despite being able to detect very small AC field amplitudes, exploiting mechanical resonances directly, implies a limitation to available signal bandwidth along with the inherent inability to detect DC or very low frequency magnetic fields. The presented work demonstrates converse ME modulation of thin film Si cantilever composites of mesoscopic dimensions (25 mm × 2.45 mm × 0.35 mm), employing piezoelectric AlN and magnetostrictive FeCoSiB films of 2 µm thickness each. A high frequency mechanical resonance at about 515 kHz leads to strong induced voltages in a surrounding pickup coil with matched self-resonance, leading to field sensitivities up to 64 kV/T. A DC limit of detection of 210 pT/Hz1/2 as well as about 70 pT/Hz1/2 at 10 Hz, without the need for a magnetic bias field, pave the way towards biomagnetic applications.