Johannes Hoffmann

Mr. Johannes Hoffmann

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
EEEric Elzenheimer
Eric Elzenheimer
CBChristin Bald
Christin Bald
EEErik Engelhardt
Erik Engelhardt
JHJohannes Hoffmann
Johannes Hoffmann
PHPatrick Hayes
Patrick Hayes
Gerhard SchmidtGerhard Schmidt
Gerhard Schmidt
Dedicated research is currently being conducted on novel thin film magnetoelectric (ME) sensor concepts for medical applications. These concepts enable a contactless magnetic signal acquisition in the presence of large interference fields such as the magnetic field of the Earth and are operational at room temperature. As more and more different ME sensor concepts are accessible to medical applications, the need for comparative quality metrics significantly arises. For a medical application, both the specification of the sensor itself and the specification of the readout scheme must be considered. Therefore, from a medical user’s perspective, a system consideration is better suited to specific quantitative measures that consider the sensor readout scheme as well. The corresponding sensor system evaluation should be performed in reproducible measurement conditions (e.g., magnetically, electrically and acoustically shielded environment). Within this contribution, an ME sensor system evaluation scheme will be described and discussed. The quantitative measures will be determined exemplarily for two ME sensors: a resonant ME sensor and an electrically modulated ME sensor. In addition, an application-related signal evaluation scheme will be introduced and exemplified for cardiovascular application. The utilized prototype signal is based on a magnetocardiogram (MCG), which was recorded with a superconducting quantum-interference device. As a potential figure of merit for a quantitative signal assessment, an application specific capacity (ASC) is introduced. In conclusion, this contribution highlights metrics for the quantitative characterization of ME sensor systems and their resulting output signals in biomagnetism. Finally, different ASC values and signal-to-noise ratios (SNRs) could be clearly presented for the resonant ME sensor (SNR: −90 dB, ASC: 9.8×10−7 dB Hz) and also the electrically modulated ME sensor (SNR: −11 dB, ASC: 23 dB Hz), showing that the electrically modulated ME sensor is better suited for a possible MCG application under ideal conditions. The presented approach is transferable to other magnetic sensors and applications.

17 July 2023 in Nano Energy
Verified
Journal Article
Closed access
MGMartha Gerhardt
Martha Gerhardt
LZLukas Zimoch
Lukas Zimoch
CDChristian Dorn
Christian Dorn
EEEric Elzenheimer
Eric Elzenheimer
CBChristin Bald
Christin Bald
RARainer Adelung
Rainer Adelung

30 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JHJohannes Hoffmann
Johannes Hoffmann
SRSebastian Roldan-Vasco
Sebastian Roldan-Vasco
KKKarolin Krüger
Karolin Krüger
MNMalte Florian Niekiel
Malte Florian Niekiel
Clint HansenClint Hansen
Clint Hansen
Gerhard SchmidtGerhard Schmidt
Gerhard Schmidt
The swallowing process involves complex muscle coordination mechanisms. When alterations in such mechanisms are produced by neurological conditions or diseases, a swallowing disorder known as dysphagia occurs. The instrumental evaluation of dysphagia is currently performed by invasive and experience-dependent techniques. Otherwise, non-invasive magnetic methods have proven to be suitable for various biomedical applications and might also be applicable for an objective swallowing assessment. In this pilot study, we performed a novel approach for deglutition evaluation based on active magnetic motion sensing with permanent magnet cantilever actuators. During the intake of liquids with different consistency, we recorded magnetic signals of relative movements between a stationary sensor and a body-worn actuator on the cricoid cartilage. Our results indicate the detection capability of swallowing-related movements in terms of a characteristic pattern. Consequently, the proposed technique offers the potential for dysphagia screening and biofeedback-based therapies.

30 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JHJohannes Hoffmann
Johannes Hoffmann
EEEric Elzenheimer
Eric Elzenheimer
CBChristin Bald
Christin Bald
Clint HansenClint Hansen
Clint Hansen
WMWalter Maetzler
Walter Maetzler
Gerhard SchmidtGerhard Schmidt
Gerhard Schmidt
Magnetoelectric (ME) sensors with a form factor of a few millimeters offer a comparatively low magnetic noise density of a few pT/Hz in a narrow frequency band near the first bending mode. While a high resonance frequency (kHz range) and limited bandwidth present a challenge to biomagnetic measurements, they can potentially be exploited in indirect sensing of non-magnetic quantities, where artificial magnetic sources are applicable. In this paper, we present the novel concept of an active magnetic motion sensing system optimized for ME sensors. Based on the signal chain, we investigated and quantified key drivers of the signal-to-noise ratio (SNR), which is closely related to sensor noise and bandwidth. These considerations were demonstrated by corresponding measurements in a simplified one-dimensional motion setup. Accordingly, we introduced a customized filter structure that enables a flexible bandwidth selection as well as a frequency-based separation of multiple artificial sources. Both design goals target the prospective application of ME sensors in medical movement analysis, where a multitude of distributed sensors and sources might be applied.

16 December 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
EEErik Engelhardt
Erik Engelhardt
EEEric Elzenheimer
Eric Elzenheimer
JHJohannes Hoffmann
Johannes Hoffmann
CMChristy Meledeth
Christy Meledeth
NFNorbert Frey
Norbert Frey
Gerhard SchmidtGerhard Schmidt
Gerhard Schmidt
Electroanatomical mapping is a method for creating a model of the electrophysiology of the human heart. Medical professionals routinely locate and ablate the site of origin of cardiac arrhythmias with invasive catheterization. Non-invasive localization takes the form of electrocardiographic (ECG) or magnetocardiographic (MCG) imaging, where the goal is to reconstruct the electrical activity of the human heart. Non-invasive alternatives to catheter electroanatomical mapping would reduce patients’ risks and open new venues for treatment planning and prevention. This work introduces a new system state-based method for estimating the electrical activity of the human heart from MCG measurements. Our model enables arbitrary propagation paths and velocities. A Kalman filter optimally estimates the current densities under the given measurements and model parameters. In an outer optimization loop, these model parameters are then optimized via gradient descent. This paper aims to establish the foundation for future research by providing a detailed mathematical explanation of the algorithm. We demonstrate the feasibility of our method through a simplified one-layer simulation. Our results show that the algorithm can learn the propagation paths from the magnetic measurements. A threshold-based segmentation into healthy and pathological tissue yields a DICE score of 0.84, a recall of 0.77, and a precision of 0.93.

28 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
JHJohannes Hoffmann
Johannes Hoffmann
EEErik Engelhardt
Erik Engelhardt
Moritz BouekeMoritz Boueke
Moritz Boueke
JWJulius Welzel
Julius Welzel
Clint HansenClint Hansen
Clint Hansen
Gerhard SchmidtGerhard Schmidt
Gerhard Schmidt
Step width is an important clinical motor marker for gait stability assessment. While laboratory-based systems can measure it with high accuracy, wearable solutions based on inertial measurement units do not directly provide spatial information such as distances. Therefore, we propose a magnetic estimation approach based on a pair of shank-worn magnetoelectric (ME) sensors. In this pilot study, we estimated the step width of eight healthy participants during treadmill walking and compared it to an optical motion capture (OMC) reference. In a direct comparison with OMC markers attached to the magnetic system, we achieved a high estimation accuracy in terms of the mean absolute error (MAE) for step width (≤1 cm) and step width variability (<0.1 cm). In a more general comparison with heel-mounted markers during the swing phase, the standard deviation of the error (<0.5 cm, measure for precision), the step width variability estimation MAE (0.88) of individual feet were still encouraging, but the accuracy was negatively affected by a constant proxy bias (3.7 and 4.6 cm) due to the different anatomical reference points used in each method. The high accuracy of the system in the first case and the high precision in the second case underline the potential of magnetic motion tracking for gait stability assessment in wearable movement analysis.