Raman spectroscopy (RS) is widely used as a non-invasive technique in screening for the diagnosis of oral cancer. The potential of this optical technique for several biomedical applications has been proved. This work studies the efficacy of RS in detecting oral cancer using sub-site-wise differentiation. A total of 80 samples (44 tumor and 36 normal) were cryopreserved from three different sub-sites: The tongue, the buccal mucosa, and the gingiva of the oral mucosa during surgery. Linear discriminant analysis (LDA) and quadratic discriminant analysis (QDA) were used with principal component analysis (PCA) to classify the samples and the classifications were validated by leave-one-out-cross-validation (LOOCV) and k-fold cross-validation methods. The normal and tumor tissues were differentiated under the PCA-LDA model with an accuracy of 81.25% (sensitivity: 77.27%, specificity: 86.11%). The PCA-QDA classifier model differentiated these tissues with an accuracy of 87.5% (sensitivity: 90.90%, specificity: 83.33%). The PCA-QDA classifier model outperformed the PCA-LDA-based classifier. The model studies revealed that protein, amino acid, and beta-carotene variations are the main biomolecular difference markers for detecting oral cancer.
A surface acoustic wave (SAW) sensor was investigated for its application in C-reactive protein (CRP) detection. Piezoelectric lithium niobate (LiNbO3) substrates were used to study their frequency response characteristics in a SAW sensor with a CRP sensing area. After the fabrication of the SAW sensor, the immobilization process was performed for CRP/anti-CRP interaction. The CRP/anti-CRP interaction can be detected as mass variations in the sensing area. These mass variations may produce changes in the amplitude of sensor response. It was clearly observed that a CRP concentration of 0.1 μg/mL can be detected in the proposed SAW sensor. A good fitting linear relationship between the detected insertion loss (amplitude) and the concentrations of CRP from 0.1 μg/mL to 1 mg/mL was obtained. The detected shifts in the amplitude of insertion loss in SAW sensors for different CRP concentrations may be useful in the diagnosis of risk of cardiovascular diseases.
Accurate identification of tissue types in surgical margins is essential for ensuring the complete removal of cancerous cells and minimizing the risk of recurrence. The objective of this study was to explore the clinical utility of Raman spectroscopy for the detection of oral squamous cell carcinoma (OSCC) in both tumor and healthy tissues obtained from surgical resection specimens during surgery. This study enrolled a total of 64 patients diagnosed with OSCC. Among the participants, approximately 50% of the cases were classified as the most advanced stage, referred to as T4. Raman experiments were conducted on cryopreserved tissue samples collected from patients diagnosed with OSCC. Prominent spectral regions containing key oral biomarkers were analyzed using the partial least squares–support vector machine (PLS–SVM) method, which is a powerful multivariate analysis technique for discriminant analysis. This approach effectively differentiated OSCC tissue from non-OSCC tissue, achieving a sensitivity of 95.7% and a specificity of 93.3% with 94.7% accuracy. In the current study, Raman analysis of fresh tissue samples showed that OSCC tissues contained significantly higher levels of nucleic acids, proteins, and several amino acids compared to the adjacent healthy tissues. In addition to differentiating between OSCC and non-OSCC tissues, we have also explored the potential of Raman spectroscopy in classifying different stages of OSCC. Specifically, we have investigated the classification of T1, T2, T3, and T4 stages based on their Raman spectra. These findings emphasize the importance of considering both stage and subsite factors in the application of Raman spectroscopy for OSCC analysis. Future work will focus on expanding our tissue sample collection to better comprehend how different subsites influence the Raman spectra of OSCC at various stages, aiming to improve diagnostic accuracy and aid in identifying tumor-free margins during surgical interventions.
In this study, we developed a novel quantitative analysis method to enhance the detection capability for oral cancer screening. We combined two different optical techniques, a light-based detection technique (visually enhanced lesion scope) and a vibrational spectroscopic technique (Raman spectroscopy). Materials and methods: Thirty-five oral cancer patients who went through surgery were enrolled. Thirty-five cancer lesions and thirty-five control samples with normal oral mucosa (adjacent to the cancer lesion) were analyzed. Thirty-five autofluorescence images and 70 Raman spectra were taken from 35 cancer and 35 control group cryopreserved samples. The normalized intensity and heterogeneity of the 70 regions of interest (ROIs) were calculated along with 70 averaged Raman spectra. Linear discriminant analysis (LDA) and quadratic discriminant analysis (QDA) were used with principal component analysis (PCA) to differentiate the cancer and control groups (normal). The classifications rates were validated using two different validation methods, leave-one-out cross-validation (LOOCV) and k-fold cross-validation. Results: The cryopreserved normal and tumor tissues were differentiated using the PCA–LDA and PCA–QDA models. The PCA–LDA of Raman spectroscopy (RS) had 82.9% accuracy, 80% sensitivity, and 85.7% specificity, while ROIs on the autofluorescence images were differentiated with 90% accuracy, 100% sensitivity, and 80% specificity. The combination of two optical techniques differentiated cancer and normal group with 97.14% accuracy, 100% sensitivity, and 94.3% specificity. Conclusion: In this study, we combined the data of two different optical techniques. Furthermore, PCA–LDA and PCA–QDA quantitative analysis models were used to differentiate tumor and normal groups, creating a complementary pathway for efficient tumor diagnosis. The error rates of RS and VELcope analysis were 17.10% and 10%, respectively, which was reduced to 3% when the two optical techniques were combined.
The aim of this study was to investigate the clinical potential of Raman spectroscopy (RS) in detecting oral squamous cell carcinoma (OSCC) in tumor and healthy tissues in surgical resection specimens during surgery. Raman experiments were performed on cryopreserved specimens from patients with OSCC. Univariate and multivariate analysis was performed based on the fingerprint region (700–1800 cm) of the Raman spectra. One hundred thirty-one ex-vivo Raman experiments were performed on 131 surgical resection specimens obtained from 67 patients. The principal component analysis (PCA) and partial least square (PLS) methods with linear discriminant analysis (LDA) were applied on an independent validation dataset. Both models were able to differentiate between the tissue types, but PLS–LDA showed 100% accuracy, sensitivity, and specificity. In this study, Raman measurements of fresh resection tissue specimens demonstrated that OSCC had significantly higher nucleic acid, protein, and several amino acid contents than adjacent healthy tissues. The specific spectral information obtained in this study can be used to develop an in vivo Raman spectroscopic method for the tumor-free resection boundary during surgery.
A surface acoustic wave (SAW) sensor with a microfluidic channel was studied to detect C-reactive protein (CRP). A piezoelectric lithium niobate substrate was used to examine the frequency response of the microfluidic SAW sensor. The amplitude (insertion loss) changes in the microfluidic SAW sensor were measured from the interaction of CRP/anti-CRP owing to mass variation. The fabricated microfluidic SAW sensor exhibited a detection limit of 4 ng/mL CRP concentration. A wide CRP concentration range (10 ng/mL to 0.1 mg/mL) can be detected by this sensor, which is higher than the existing CRP detection methods. A good linear relationship between the amplitude peak shift and CRP concentrations from 10 ng/mL to 0.1 mg/mL was obtained. The amplitude peak shifts in the sensor can be useful for estimating CRP concentration. This can be used as a biosensor to diagnose the risk of cardiovascular disease.