Permanent magnet synchronous machines (PMSMs), which include a dynamic combination of electronics and mechanics, have been widely deployed in emerging mechatronics systems. However, there exist undesirable perturbations in electrical and mechanical parameters of the PMSM with different operating conditions, which deteriorate the control performance and pose risks to the connected power conversion systems. To improve the robustness of PMSM control considering multiple system perturbations, a robust control strategy with parametric adaptation is established in this paper, where a desired-compensation adaptive robust current controller and a disturbance-observer-based speed controller are proposed. Such controls are capable of achieving robust regulations of the stator currents and the rotor speed, while accurately estimating machine parameters including stator resistance, stator inductance, and flux linkage of the permanent magnet. When these parameters drift away from their nominal values, the observers/estimators of the proposed algorithms calibrate the pre-stored data and compensate for the control errors, and thus the control behavior of the PMSM under parameter mismatches will not degrade. A current and speed cascaded control system is configured to integrate the proposed algorithms for robustness considerations of the PMSM. Extensive simulations and experimental results are demonstrated to validate the effectiveness of the proposed robust control strategies.
1 August 2019 in IEEE Transactions on Energy Conversion
In various applications that utilize maximum torque per ampere (MTPA) operation of interior permanent magnet synchronous machines (IPMSMs), there exist unexpected perturbations in electrical parameters and operating environment, which deteriorate the accuracy and efficiency of the MTPA operation. This paper establishes a step-signal-injection-based robust MTPA operation strategy for the IPMSM drives. The method works by injecting a step-signal into the current vector angle and observing the response in the current magnitude, followed by a proportional-integral controller which returns the system to optimal operation. The stability of the proposed algorithm is established using the Lyapunov theory. A speed-servo control system of IPMSM is considered, where a disturbance detection unit is designed to switch operation between optimal current angle updating mode and steady-state MTPA mode. Since the optimal current angle updating is independent of machine parameters, the impact of system perturbations on the MTPA operation can be effectively suppressed. Extensive experimental results for IPMSM and hardware-in-the-loop-based machine are presented to validate the effectiveness and robustness of the proposed method.
21 January 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Unexpected faults that occur in the sensors of the single-phase grid-connected converter (SGC) may deteriorate the control performance ofthe grid current and dc-link voltage and pose risks to the connected distributed generation system. This article proposes an unknown input sliding mode observer (UI-SMO) based sensor fault identification and remediation strategy. Therein, an UI-SMO is established that integrates the observations of the grid current and dc-link voltage with the reconstruction of the unknown input (i.e., load condition of the SGC). Such an observer-based analytical redundancy generates the residuals that indicate the abnormalities of the sensors for fault identification. An adaptive fault-tolerant control (AFTC) strategy for the SGC is developed, where an automated control system reconfiguration with unknown input adaptation is seamlessly implemented by substituting the data reported by the faulty sensors with their observed values. Extensive simulation and experimental studies validate the effectiveness of the proposed UI-SMO-based sensor fault identification and AFTC strategy of the SGC.
9 March 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Four-switch three-phase inverters (FSTPIs) are generally applied as fault-tolerant topologies or cost-effective topologies for induction motor (IM) drives. However, conventional predictive torque control (PTC) for FSTPI-fed IM suffers from poor steady-state performance and tedious weighting factor assignment. In this article, a PTC based on discrete space vector modulation (PTC-DSVM) for an FSTPI-fed IM drive is proposed. First, the relationship between the dc-link capacitor voltage offset (CVO) and the load current is derived, and a stator voltage compensation strategy is proposed to suppress the CVO. Meanwhile, a reference-voltage-vector-error-based cost function that combines the reference stator flux vector control, the stator voltage compensation strategy, and the deadbeat control is designed to fully eliminate the weighting factors in the cost function of the conventional PTC. In addition, a DSVM scheme is developed to increase the number of admissible voltage vectors and improve the steady-state performance of IM drives. A preselection algorithm based on the offset voltage vector and sector division is designed to reduce the number of candidate voltage vectors. Extensive simulations and experimental results with a 2.2-kW IM are demonstrated to validate the effectiveness of the proposed control strategy.
14 July 2020 in IEEE Transactions on Industry Applications
The high common-mode voltage (CMV) generated by conventional synchronized space vector pulsewidth modulation (SVPWM) strategies may lead to bearing failure and electromagnetic interference problems. However, existing CMV reduction methods are based on asynchronized SVPWM, which will cause unacceptable harmonic distortion at low switching frequency. In this paper, four modified synchronized SVPWM (MS-SVPWM) strategies are presented to reduce the CMV and improve the output performance of three-phase voltage source inverters (VSIs) at low switching frequency. In the proposed methods, only nonzero vectors are employed to reduce CMV, and the constraint conditions of preserving three-phase, half-wave, and quarter-wave symmetries of PWM waveforms in terms of active vectors are established. A pre-correction scheme is proposed and applied to the presented MS-SVPWM strategies to achieve an accurate output voltage of inverters. Moreover, the linearity characteristics of the output voltage, the harmonic performance of line-line voltage and CMV, and the stator flux trajectories of the proposed strategies are investigated and compared. Experimental results for a 2.2-kW induction motor fed by a two-level VSI are presented to illustrate the effectiveness of the proposed MS-SVPWM strategies.