Xiaohua Zhang

Xiaohua Zhang

Auto-generated profile, based on publicly available information

Xiaohua Zhang

School of Electrical Engineering, Dalian University of Technology, Dalian, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
JXJinhui Xia
Jinhui Xia
ZLZe Li
Ze Li
DYDonghui Yu
Donghui Yu
YGYuanbo Guo
Yuanbo Guo
XZXiaohua Zhang
Xiaohua Zhang
Permanent magnet synchronous machines (PMSMs), which include a dynamic combination of electronics and mechanics, have been widely deployed in emerging mechatronics systems. However, there exist undesirable perturbations in electrical and mechanical parameters of the PMSM with different operating conditions, which deteriorate the control performance and pose risks to the connected power conversion systems. To improve the robustness of PMSM control considering multiple system perturbations, a robust control strategy with parametric adaptation is established in this paper, where a desired-compensation adaptive robust current controller and a disturbance-observer-based speed controller are proposed. Such controls are capable of achieving robust regulations of the stator currents and the rotor speed, while accurately estimating machine parameters including stator resistance, stator inductance, and flux linkage of the permanent magnet. When these parameters drift away from their nominal values, the observers/estimators of the proposed algorithms calibrate the pre-stored data and compensate for the control errors, and thus the control behavior of the PMSM under parameter mismatches will not degrade. A current and speed cascaded control system is configured to integrate the proposed algorithms for robustness considerations of the PMSM. Extensive simulations and experimental results are demonstrated to validate the effectiveness of the proposed robust control strategies.

8 March 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JXJinhui Xia
Jinhui Xia
YGYuanbo Guo
Yuanbo Guo
XZXiaohua Zhang
Xiaohua Zhang
JJJuri Jatskevich
Juri Jatskevich
NANavid Amiri
Navid Amiri

1 August 2019 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
JXJinhui Xia
Jinhui Xia
YGYuanbo Guo
Yuanbo Guo
ZLZe Li
Ze Li
JJJuri Jatskevich
Juri Jatskevich
XZXiaohua Zhang
Xiaohua Zhang
In various applications that utilize maximum torque per ampere (MTPA) operation of interior permanent magnet synchronous machines (IPMSMs), there exist unexpected perturbations in electrical parameters and operating environment, which deteriorate the accuracy and efficiency of the MTPA operation. This paper establishes a step-signal-injection-based robust MTPA operation strategy for the IPMSM drives. The method works by injecting a step-signal into the current vector angle and observing the response in the current magnitude, followed by a proportional-integral controller which returns the system to optimal operation. The stability of the proposed algorithm is established using the Lyapunov theory. A speed-servo control system of IPMSM is considered, where a disturbance detection unit is designed to switch operation between optimal current angle updating mode and steady-state MTPA mode. Since the optimal current angle updating is independent of machine parameters, the impact of system perturbations on the MTPA operation can be effectively suppressed. Extensive experimental results for IPMSM and hardware-in-the-loop-based machine are presented to validate the effectiveness and robustness of the proposed method.

1 January 2021 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
XLXianzhuang Liu
Xianzhuang Liu
YMYong Min
Yong Min
LCLei Chen
Lei Chen
XZXiaohua Zhang
Xiaohua Zhang
CFChangyou Feng
Changyou Feng

21 January 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ZLZe Li
Ze Li
YGYuanbo Guo
Yuanbo Guo
JXJinhui Xia
Jinhui Xia
HLHaoyang Li
Haoyang Li
XZXiaohua Zhang
Xiaohua Zhang

12 April 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JXJinhui Xia
Jinhui Xia
ZLZe Li
Ze Li
XGXiaonan Gao
Xiaonan Gao
YGYuanbo Guo
Yuanbo Guo
XZXiaohua Zhang
Xiaohua Zhang
Unexpected faults that occur in the sensors of the single-phase grid-connected converter (SGC) may deteriorate the control performance ofthe grid current and dc-link voltage and pose risks to the connected distributed generation system. This article proposes an unknown input sliding mode observer (UI-SMO) based sensor fault identification and remediation strategy. Therein, an UI-SMO is established that integrates the observations of the grid current and dc-link voltage with the reconstruction of the unknown input (i.e., load condition of the SGC). Such an observer-based analytical redundancy generates the residuals that indicate the abnormalities of the sensors for fault identification. An adaptive fault-tolerant control (AFTC) strategy for the SGC is developed, where an automated control system reconfiguration with unknown input adaptation is seamlessly implemented by substituting the data reported by the faulty sensors with their observed values. Extensive simulation and experimental studies validate the effectiveness of the proposed UI-SMO-based sensor fault identification and AFTC strategy of the SGC.