Jinhui Xia

Dr. Jinhui Xia

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
SZShiyi Zhao
Shiyi Zhao
Qinmin YangQinmin Yang
Qinmin Yang
PCPeng Cheng
Peng Cheng
RDRuilong Deng
Ruilong Deng
JXJinhui Xia
Jinhui Xia
With the increasing expansion of wind power installed capacity, the deployed wind farms are becoming an attractive target for malicious entities. The geographical scale of the wind farm, remoteness of its location, flat logical control network, and fragile control protocols make it vulnerable to cyber attacks. False data injection (FDI) attacks on the value of the rotor speed may lead to reduced power generation efficiency, overload of the drive-train, and even shutdowns and potentially costly equipment damage of wind turbines. Therefore, in this article, we attempt to propose an adaptive resilient control scheme for the variable-speed wind turbine (VSWT) operating at low-speed region in face of FDI attacks. The control goal is to meet the requirements in the low-speed operation of the WT and to optimize the power drawn from the wind by adjusting the generator torque in the presence of cyber attacks. Therein, a dynamic detection method based on rotor speed observer/estimator is designed to identify the FDI attacks. After locating the attack, an adaptive resilient control strategy for the generator torque is implemented to guarantee the control target of optimal power tracking and improve the attack resiliency of the WT control system. Extensive studies are carried out on a 1.5 MW doubly-fed induction generator-based WT, and the simulation results indicate that the proposed control strategy could effectively reduce both network and physical impacts caused by cyber attacks.

5 July 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
MLMengxiang Liu
Mengxiang Liu
CZChengcheng Zhao
Chengcheng Zhao
JXJinhui Xia
Jinhui Xia
RDRuilong Deng
Ruilong Deng
PCPeng Cheng
Peng Cheng
JCJiming Chen
Jiming Chen
With the rapid development of the information and communication technology in DC microgrids (DCmGs), the threat of deception attacks has been widely recognized. However, the stealthy deception attacks, which can hide the actual attack impact from the system operator as in the Stuxnet accident, have not yet been well studied. Towards this end, this paper proposes a proactive distributed detection and localization (PDDL) framework to defend against the stealthy deception attacks. The attack detection is achieved by observing the attack impact that is quantified as the voltage balancing deviation (VBD) and current sharing deviation (CSD) in DCmGs. Once any anomaly is perceived, the proactive perturbation on primary control gains (PCGs) will be activated to invalidate the previously inferred PCGs of the attacker, under which the constructed stealthy deception attacks may be located by the unknown input observer (UIO) based locators. To maximize the locatability of attacks while limiting the induced transient fluctuations on system states, an optimization problem is formulated to determine the PCG perturbation magnitude. Finally, the effectiveness of the PDDL framework is verified through extensive hardware-in-the-loop (HIL) based simulations and systematic full-hardware experimental studies.

10 August 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
JXJinhui Xia
Jinhui Xia
ZLZe Li
Ze Li
DYDonghui Yu
Donghui Yu
YGYuanbo Guo
Yuanbo Guo
XZXiaohua Zhang
Xiaohua Zhang
Permanent magnet synchronous machines (PMSMs), which include a dynamic combination of electronics and mechanics, have been widely deployed in emerging mechatronics systems. However, there exist undesirable perturbations in electrical and mechanical parameters of the PMSM with different operating conditions, which deteriorate the control performance and pose risks to the connected power conversion systems. To improve the robustness of PMSM control considering multiple system perturbations, a robust control strategy with parametric adaptation is established in this paper, where a desired-compensation adaptive robust current controller and a disturbance-observer-based speed controller are proposed. Such controls are capable of achieving robust regulations of the stator currents and the rotor speed, while accurately estimating machine parameters including stator resistance, stator inductance, and flux linkage of the permanent magnet. When these parameters drift away from their nominal values, the observers/estimators of the proposed algorithms calibrate the pre-stored data and compensate for the control errors, and thus the control behavior of the PMSM under parameter mismatches will not degrade. A current and speed cascaded control system is configured to integrate the proposed algorithms for robustness considerations of the PMSM. Extensive simulations and experimental results are demonstrated to validate the effectiveness of the proposed robust control strategies.

15 February 2023 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
MWMengzhi Wang
Mengzhi Wang
CZChengcheng Zhao
Chengcheng Zhao
JXJinhui Xia
Jinhui Xia
JSJian Sun
Jian Sun
This paper investigates the problem of event-triggered distributed model predictive control (DMPC) for continuous-time nonlinear multi-agent systems (MASs) subject to bounded disturbances, input and communication delays simultaneously. The compensation schemes for input and communication delays are proposed, respectively. A new optimal control problem (OCP) to achieve consensus among all agents is formulated under the proposed delay compensation schemes. To alleviate the communication burden and sensing cost, a novel input delay-related periodic event-triggering condition is proposed based on the state error to determine when to calculate the new control input. Sufficient condition guaranteeing the feasibility of the OCP is achieved with the proposed event-triggered control scheme. In stability analysis, a novel time-varying Lyapunov function is constructed, and the input-to-state practical stability (ISpS) of the MASs is derived by using the quasi-Lipschitz continuous property of the Lyapunov function. Numerical results related to vehicle platooning demonstrate the effectiveness of the proposed event-triggered DMPC.

25 November 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
SZShiyi Zhao
Shiyi Zhao
JXJinhui Xia
Jinhui Xia
RDRuilong Deng
Ruilong Deng
PCPeng Cheng
Peng Cheng
Qinmin YangQinmin Yang
Qinmin Yang
XJXuguo Jiao
Xuguo Jiao
The increasing utilization of wind energy necessitates dedicated attentions to identify vulnerabilities, raise awareness, and formulate strategies for cybersecurity defense, response, and future protection. As a potential cyber attack, denial-of-service (DoS) attacks that block the communication between the rotor speed sensor and the controller of the wind turbine may overload the drive-train and reduce the power generation efficiency. This paper attempts to propose a dual-triggered resilient torque control strategy for the variable-speed wind turbine (VSWT) against DoS attacks. Therein, the mathematical models including the dynamics of the WT and the DoS attack are established, and a neural network observer is designed for the WT system to compensate for the signal losses caused by DoS attack. To guarantee the optimal rotor speed tracking of the WT, an adaptive torque control method based on dual-triggered mechanism is developed, and the attack tolerance capability of the WT system is evaluated. The proposed control strategy can largely enhance the attack resilience capability of the WT, while saving the resources of computation and communication. Extensive studies on a 1.5 MW WT illustrate that the proposed adaptive resilient control scheme can effectively mitigate the impact of the DoS attacks and guarantee the optimal rotor speed tracking performance for the WT system.

8 March 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JXJinhui Xia
Jinhui Xia
YGYuanbo Guo
Yuanbo Guo
XZXiaohua Zhang
Xiaohua Zhang
JJJuri Jatskevich
Juri Jatskevich
NANavid Amiri
Navid Amiri