Minor-destructive (MDT) and non-destructive (NDT) techniques are not commonly used for masonry as they are complex and difficult to perform. This paper describes validation of the following methods: semi-non-destructive, non-destructive, and ultrasonic technique for autoclaved aerated concrete (AAC). The subject of this study covers the compressive strength of AAC test elements with declared various density classes of: 400, 500, 600, and 700 (kg/m3), at various moisture levels. Empirical data including the shape and size of specimens, were established from tests on 494 cylindrical and cuboid specimens, and standard cube specimens 100 mm × 100 mm × 100 mm using the general relationship for ordinary concrete (Neville’s curve). The effect of moisture on AAC was taken into account while determining the strength fBw for 127 standard specimens tested at different levels of water content (w = 100%, 67%, 33%, 23%, and 10%). Defined empirical relations were suitable to correct the compressive strength of dry specimens. For 91 specimens 100 mm × 100 mm × 100 mm, the P-wave velocity cp was tested with the transmission method using the ultrasonic pulse velocity method with exponential transducers. The curve (fBw–cp) for determining the compressive strength of AAC elements with any moisture level (fBw) was established. The developed methods turned out to be statistically significant and can be successfully applied during in-situ tests. Semi-non-destructive testing can be used independently, whereas the non-destructive technique can be only applied when the developed curve fbw–cp is scaled.
This article presents results from non-destructive testing (NDT) that referred to the location and diameter or rebars in beam and slab members. The aim of paper was to demonstrate that the accuracy and deviations of the NDT methods could be higher than the allowable execution or standard deviations. Tests were conducted on autoclaved aerated concrete beam and nine specimens that were specially prepared from lightweight concrete. The most advanced instruments that were available on the market were used to perform tests. They included two electromagnetic scanners and one ground penetrating radar (GPR). The testing equipment was used to analyse how the rebar (cover) location affected the detection of their diameters and how their mutual spacing influenced the detected quantity of rebars. The considerations included the impact of rebar depth on cover measurements and the spread of obtained results. Tests indicated that the measurement error was clearly greater when the rebars were located at very low or high depths. It could lead to the improper interpretation of test results, and consequently to the incorrect estimation of the structure safety based on the design resistance analysis. Electromagnetic and radar devices were unreliable while detecting the reinforcement of small (8 and 10 mm) diameters at close spacing (up to 20 mm) and of large (20 mm) diameters at a close spacing and greater depths. Recommendations for practical applications were developed to facilitate the evaluation of a structure.
Currently, electromagnetic and radar methods are the most common non-destructive tests for non-destructive rebar location in structures.. Both methods have some advantages, disadvantages and limitations. This article is an attempt to describe possibilities of particular methods with emphasizing their advantages and limitations. The first stage of tests included results from tests conducted on a lintel beam made of autoclaved aerated concrete (AAC) and reinforced with small-diameter rebars and rebars placed close to each other. The second stage consisted in testing nine lightweight concrete specimens, each with three bars having a diameter of 10, 16 and 20 mm at three different space arrangements, to determine the effect of bar diameter and spacing on the measurement accuracy. The reinforcement of lintels and specimens was tested with two different electromagnetic scanners and a ground-penetrating radar (GPR) device. Received results from direct tests were compared with results from non-destructive tests (NDT). NDT tests conducted in such an element were found to perform the correct assessment of the concrete cover, and at the same time to give ambiguous results with reference to shape and number of rebars.
The paper presents the results of precast lintels made of AAC with a total length 2.0 m. The study was divided into two series of basic and general. In the basic series, lintel was studied according to the recommendations of codes EN 846-9: 2002 and EN 1356: 1999. In the general series consisting of the 6 models, lintels with an interacting wall of varying heights were examined. During the test, forces, displacements and deformations were measured using inductive transducers forces and displacements. The basic and the general series demonstrated, among other things, that the destruction of the elements followed in the zone of supporting due to shear
In this study, qualitative tests were carried out to compare the behaviour of selected slabs exposed to short- and long-term loading. Full-scale models of the half-slab and hollow-core slab with dimensions of 6.30 m × 6.30 m, built of four different precast panels, were tested. The first two were semi-precast lattice girder slabs, the third semi-precast prestressed ribbed panels, and the last was composed of hollow-core panels. A common feature was the lack of joint reinforcement and the same modular width of 600 mm. The short-term load was applied sequentially in the first stage, and displacement was measured using an electronic method. In the second stage of long-term testing, the load was mainly applied to one part of the slab. Testing under short-term and long-term load allows determining the change in the performance of panel slabs over time. The panels maintained the ability of load redistribution based on their interaction despite the work of the longitudinal joints being only through the concrete cross-section. The behaviour of slabs with concrete topping shows more significant lateral interactions than elements connected only by shear key. Comparative calculations were made based on four computational models. Comparative analysis showed that the current design procedures lead to a safe but conservative estimation of the slab behaviour.