Łukasz Drobiec

Prof. Dr. Łukasz Drobiec

Silesian University of Technology, Gliwice, Poland
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
Julia BlazyJulia Blazy
Julia Blazy
RBRafał Blazy
Rafał Blazy
Łukasz DrobiecŁukasz Drobiec
Łukasz Drobiec
The article highlights that glass fiber reinforced concretes (GFRC) can meet the requirements of Smart City better than ordinary concretes. The comprehensive discussion on GFRC composition is presented together with the review of glass fibers’ influence on various concrete properties. First of all, because of their bridging abilities, they can limit the width, length, and total area of cracks. Additionally, GFRC are characterized by enhanced tensile, flexural, and splitting strength; impact, abrasion, spalling, fire, and freeze-thaw resistance as well as ductility, toughness, and permeability. All of this positively influences the mechanical behavior, durability, and corrosion resistance of concrete elements. Moreover, decreased thermal conductivity allows for better energy performance from the building’s point of view. This results in cheaper structures both in manufacturing and maintaining even though GFRC are more expensive materials. However, mechanical properties enhance as long as sufficient workability and uniform fiber distribution are assured. From the environmental point of view, GFRC are eco-friendlier materials than ordinary concretes since their application can decrease the emission of CO2 by 17%. The article also describes the GFRC application fields and emphasizes the possibility of the creation of not only structural elements mainly intended for load transferring but also elements accompanying the building process, as well as elements of small architecture that make public spaces more attractive, durable, and safer. Owing to greater design and shaping freedom, GFRC can also better fulfill the needs of habitants of Smart City.

26 January 2019 in Materials
Verified
Journal Article
Open access
PDF file
Radosław JasińskiRadosław Jasiński
Radosław Jasiński
Łukasz DrobiecŁukasz Drobiec
Łukasz Drobiec
WMWojciech Mazur
Wojciech Mazur
Minor-destructive (MDT) and non-destructive (NDT) techniques are not commonly used for masonry as they are complex and difficult to perform. This paper describes validation of the following methods: semi-non-destructive, non-destructive, and ultrasonic technique for autoclaved aerated concrete (AAC). The subject of this study covers the compressive strength of AAC test elements with declared various density classes of: 400, 500, 600, and 700 (kg/m3), at various moisture levels. Empirical data including the shape and size of specimens, were established from tests on 494 cylindrical and cuboid specimens, and standard cube specimens 100 mm × 100 mm × 100 mm using the general relationship for ordinary concrete (Neville’s curve). The effect of moisture on AAC was taken into account while determining the strength fBw for 127 standard specimens tested at different levels of water content (w = 100%, 67%, 33%, 23%, and 10%). Defined empirical relations were suitable to correct the compressive strength of dry specimens. For 91 specimens 100 mm × 100 mm × 100 mm, the P-wave velocity cp was tested with the transmission method using the ultrasonic pulse velocity method with exponential transducers. The curve (fBw–cp) for determining the compressive strength of AAC elements with any moisture level (fBw) was established. The developed methods turned out to be statistically significant and can be successfully applied during in-situ tests. Semi-non-destructive testing can be used independently, whereas the non-destructive technique can be only applied when the developed curve fbw–cp is scaled.

7 August 2021 in Materials
Verified
Journal Article
Open access
PDF file
Julia BlazyJulia Blazy
Julia Blazy
Łukasz DrobiecŁukasz Drobiec
Łukasz Drobiec
PWPaweł Wolka
Paweł Wolka
Fiber reinforcement is currently most often used in floors, railway sleepers, prefabricated structural elements such as slabs, beams and tanks, and in small architecture elements. Designing elements or structures made of fiber-reinforced concrete requires knowledge of its basic mechanical parameters. In the case of concretes with metallic fibers, the literature can find many tests and standard guidelines regarding compressive, flexural, tensile strength and fracture energy. The properties of concretes with non-metallic fibers are slightly less recognized, especially concretes with new types of polymer fibers. Additionally, the lack of standardized methods of testing concrete with polymer fibers make their application much more difficult. In the article, the possibility of using the EN 14651 standard to assess the flexural tensile strength of concrete with the addition of 2.0 and 3.0 kg/m3 of synthetic fibers with different geometry and form was presented. There was a 5.5–13.5% increase in the flexural tensile strength depending on the mixture type. Moreover, in the case of fiber-reinforced concretes, the ductility was enhanced and the samples were characterized by significant residual flexural tensile strengths. Additionally, from the workability tests it was concluded that after the incorporation of fibers, the consistency class decreased by one, two or three. Nevertheless, the compressive strengths of concrete with and without fibers were very similar to each other, and varied from 58.05 to 61.31 MPa. Moreover, it was concluded that results obtained from three-point bending tests significantly differed from empirical formulas for the calculation of the flexural tensile strength of fiber-reinforced concretes with dispersed steel fibers present in the literature. As a result, the new formula determined by the authors was proposed for concrete with polymer fibers with a nominal fiber content ≤1.0% and slenderness of up to 200. It must be mentioned that the formula gave a very good agreement with studies presented in different literature positions. In addition, an attempt was made to evaluate the strengths of tested mixes in accordance with the Model Code 2010. However, it occurred that the proposed fiber-reinforced concrete mixtures would not be able to replace traditional reinforcement in a form of steel bars. Furthermore, in uniaxial tensile tests, it was not possible to determine the σ–w graphs, and received results for maximum tensile strength did not show the clear influence of fibers incorporation on concrete. Then, the fracture energy enhancement (from about 16 to 22 times) and dependencies: crack mouth opening displacement–deflection; crack mouth opening displacement–crack tip opening displacement; and crack tip opening displacement–deflection were analyzed. Finally, the results from flexural tensile tests were compared with measurements of the surface displacement field obtained through the Digital Image Correlation technique. It was concluded that this technique can be successfully used to determine the crack mouth and crack tip opening displacements with very high accuracy.

10 April 2019 in Materials
Verified
Journal Article
Open access
PDF file
Łukasz DrobiecŁukasz Drobiec
Łukasz Drobiec
Radosław JasińskiRadosław Jasiński
Radosław Jasiński
WMWojciech Mazur
Wojciech Mazur
This article presents results from non-destructive testing (NDT) that referred to the location and diameter or rebars in beam and slab members. The aim of paper was to demonstrate that the accuracy and deviations of the NDT methods could be higher than the allowable execution or standard deviations. Tests were conducted on autoclaved aerated concrete beam and nine specimens that were specially prepared from lightweight concrete. The most advanced instruments that were available on the market were used to perform tests. They included two electromagnetic scanners and one ground penetrating radar (GPR). The testing equipment was used to analyse how the rebar (cover) location affected the detection of their diameters and how their mutual spacing influenced the detected quantity of rebars. The considerations included the impact of rebar depth on cover measurements and the spread of obtained results. Tests indicated that the measurement error was clearly greater when the rebars were located at very low or high depths. It could lead to the improper interpretation of test results, and consequently to the incorrect estimation of the structure safety based on the design resistance analysis. Electromagnetic and radar devices were unreliable while detecting the reinforcement of small (8 and 10 mm) diameters at close spacing (up to 20 mm) and of large (20 mm) diameters at a close spacing and greater depths. Recommendations for practical applications were developed to facilitate the evaluation of a structure.

1 January 2016 in Procedia Engineering
Verified
Journal Article
Open access
Radosław JasińskiRadosław Jasiński
Radosław Jasiński
Łukasz DrobiecŁukasz Drobiec
Łukasz Drobiec
In the article research of the influence of bed joint reinforcement on the compressive and shear strength of Autoclaved Aerated Concrete (AAC, 600kg/m3 type) masonry were described. 18 reinforced models under compression and 18 specimens under diagonal compression were tested according to guidelines of EN 1052-1:2000 [4] and ASTM E519-81 [1] code. The tests of compressive walls showed that the reinforcement influenced on the compressive strength and deformability of wall. Research of shear walls has shown, that the most beneficial effect on shear strength obtained using steel structural truss type reinforcement when mortar applying on the upper and down bed surfaces of units (double joints)

8 September 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Łukasz DrobiecŁukasz Drobiec
Łukasz Drobiec
KGKrzysztof Grzyb
Krzysztof Grzyb
Jakub ZającJakub Zając
Jakub Zając
Each historic building or cultural heritage site requires proper care at every stage of its life cycle. Appropriate interventions aim to prevent building disasters and preserve invaluable cultural objects from ageing or deterioration processes. This article is a case study of mistakes made in various phases of a building’s life—in the design, execution, and use. The work aims to point out various aspects of the errors made during the building’s restoration. The conducted material research, computational analyses, laboratory tests, and documentation studies comprehensively consider the presented examples. The structural analysis of the buildings consists of its load-bearing capacity and its stability.