Saša Novak

Dr. Saša Novak


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in Radiology and Oncology
Verified
Journal Article
Open access
PDF file
MSMatej Skocaj
Matej Skocaj
MFMetka Filipic
Metka Filipic
JPJana Petkovic
Jana Petkovic
SNSaša Novak
Saša Novak
Titanium dioxide (TiO(2)) is considered as an inert and safe material and has been used in many applications for decades. However, with the development of nanotechnologies TiO(2) nanoparticles, with numerous novel and useful properties, are increasingly manufactured and used. Therefore increased human and environmental exposure can be expected, which has put TiO(2) nanoparticles under toxicological scrutiny. Mechanistic toxicological studies show that TiO(2) nanoparticles predominantly cause adverse effects via induction of oxidative stress resulting in cell damage, genotoxicity, inflammation, immune response etc. The extent and type of damage strongly depends on physical and chemical characteristics of TiO(2) nanoparticles, which govern their bioavailability and reactivity. Based on the experimental evidence from animal inhalation studies TiO(2) nanoparticles are classified as "possible carcinogenic to humans" by the International Agency for Research on Cancer and as occupational carcinogen by the National Institute for Occupational Safety and Health. The studies on dermal exposure to TiO(2) nanoparticles, which is in humans substantial through the use of sunscreens, generally indicate negligible transdermal penetration; however data are needed on long-term exposure and potential adverse effects of photo-oxidation products. Although TiO(2) is permitted as an additive (E171) in food and pharmaceutical products we do not have reliable data on its absorption, distribution, excretion and toxicity on oral exposure. TiO(2) may also enter environment, and while it exerts low acute toxicity to aquatic organisms, upon long-term exposure it induces a range of sub-lethal effects. Until relevant toxicological and human exposure data that would enable reliable risk assessment are obtained, TiO(2) nanoparticles should be used with great care.

6 March 2017 in Biomedical Materials
Verified
Journal Article
Open access
PDF file
RKRok Kocen
Rok Kocen
Michael GasikMichael Gasik
Michael Gasik
AGAna Gantar
Ana Gantar
SNSaša Novak
Saša Novak
Along with biocompatibility, bioinductivity and appropriate biodegradation, mechanical properties are also of crucial importance for tissue engineering scaffolds. Hydrogels, such as gellan gum (GG), are usually soft materials, which may benefit from the incorporation of inorganic particles, e.g. bioactive glass, not only due to the acquired bioactivity, but also due to improved mechanical properties. They exhibit complex viscoelastic properties, which can be evaluated in various ways. In this work, to reliably evaluate the effect of the bioactive glass (BAG) addition on viscoelastic properties of the composite hydrogel, we employed and compared the three most commonly used techniques, analyzing their advantages and limitations: monotonic uniaxial unconfined compression, small amplitude oscillatory shear (SAOS) rheology and dynamic mechanical analysis (DMA). Creep and small amplitude dynamic strain-controlled tests in DMA are suggested as the best ways for the characterization of mechanical properties of hydrogel composites, whereas the SAOS rheology is more useful for studying the hydrogel’s processing kinetics, as it does not induce volumetric changes even at very high strains. Overall, the results confirmed a beneficial effect of BAG (nano)particles on the elastic modulus of the GG–BAG composite hydrogel. The Young’s modulus of 6.6 ± 0.8 kPa for the GG hydrogel increased by two orders of magnitude after the addition of 2 wt.% BAG particles (500–800 kPa).

1 October 2014 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
AGAna Gantar
Ana Gantar
Lucília P da SilvaLucília P da Silva
Lucília P da Silva
Joaquim OliveiraJoaquim Oliveira
Joaquim Oliveira
Alexandra P. MarquesAlexandra P. Marques
Alexandra P. Marques
Vitor M. CorreloVitor M. Correlo
Vitor M. Correlo
RRRui M. Reis
Rui M. Reis

16 March 2012 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
NDNataša Drnovšek
Nataša Drnovšek
SNSaša Novak
Saša Novak
UDUrška Dragin
Urška Dragin
MČMiran Čeh
Miran Čeh
MGMatevž Gorenšek
Matevž Gorenšek
MGMarko Gradišar
Marko Gradišar

2 January 2014 in Materials
Verified
Journal Article
Open access
PDF file
MLMartina Lorenzetti
Martina Lorenzetti
EPEva Pellicer
Eva Pellicer
Jordi SortJordi Sort
Jordi Sort
MBMaria Dolors Baró
Maria Dolors Baró
JKJanez Kovač
Janez Kovač
SKSpomenka Kobe
Spomenka Kobe
The electrochemical behavior of polycrystalline TiO2 anatase coatings prepared by a one-step hydrothermal synthesis on commercially pure (CP) Ti grade 2 and a Ti13Nb13Zr alloy for bone implants was investigated in Hank’s solution at 37.5 °C. The aim was to verify to what extent the in-situ-grown anatase improved the behavior of the substrate in comparison to the bare substrates. Tafel-plot extrapolations from the potentiodynamic curves revealed a substantial improvement in the corrosion potentials for the anatase coatings. Moreover, the coatings grown on titanium also exhibited lower corrosion-current densities, indicating a longer survival of the implant. The results were explained by considering the effects of crystal morphology, coating thickness and porosity. Evidence for the existing porosity was obtained from corrosion and nano-indentation tests. The overall results indicated that the hydrothermally prepared anatase coatings, with the appropriate morphology and surface properties, have attractive prospects for use in medical devices, since better corrosion protection of the implant can be expected.

1 November 2004 in Tribology Letters
Verified
Journal Article
Closed access
PDF file
SNSaša Novak
Saša Novak
MKM. Kalin
M. Kalin