Lei Wang

Dr. Lei Wang

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2019 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
WSWeiheng Shao
Weiheng Shao
WFwenxiao FANG
wenxiao FANG
YHYun Huang
Yun Huang
GLGuangwei Li
Guangwei Li
LWLei Wang
Lei Wang
BYBin Yao
Bin Yao
A near field scanning is usually time-consuming to map the electromagnetic field along the surface of a device. In this paper, a dual probe is proposed with a U-shaped loop to sense radio-frequency (RF) magnetic and electric fields simultaneously, so that the one-time scanning by the dual probe can replace the two-time scanning by single detector probes. Different from the traditional near field scanning by using a single detector probe and spectrum analyzer, the proposed scanning can be achieved by the two-output probe and a two-port vector network analyzer connecting to the probe. The efficient near field scanning measurements of the electric and magnetic field on a conductorbacked coplanar waveguide transmission line and an RF power divider by using the dual probe are in agreement with those by using two single detector probes.

16 August 2021 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
LWLei Wang
Lei Wang
ZZZhang-Ming Zhu
Zhang-Ming Zhu
YEYunfei En
Yunfei En
In this letter, two novel broadband circularly polarized slot-microstrip antennas (SMPA) with circular and square structures are elaborated. The circular SMPA is composed of four crown patches as parasitic elements, four crown slots etched on a circular ground plane, and a circular loop sequential phase feeding structure. However, the square SMPA consists of four parasitic rectangular patches, four square slots with cut corners, and a square-loop feeding structure. In the circular SMPA, the parasitic crown patches and crown slots are used to excite multiple circularly polarized (CP) resonant modes, which are fed by a circular loop sequential phase feeding structure through capacitive coupling. Combined with these CP modes, the CP bandwidth of the presented antenna could be improved. Eventually, the proposed circular SMPA has a broad 3-dB axial ratio bandwidth (ARBW) of 20.6% (5.206.40, 5.8 GHz) and a wide 10-dB impedance bandwidth (IBW) of 25.8% (4.926.38, 5.65 GHz), which could occupy the WLAN (5.7255.85 GHz), ITS (5.8 GHz), and WIFI (5.85-5.925 GHz) bands.

12 May 2021 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
SYShaozhong Yue
Shaozhong Yue
ZZZhangang Zhang
Zhangang Zhang
ZCZiwen Chen
Ziwen Chen
Xuefeng ZhengXuefeng Zheng
Xuefeng Zheng
LWLei Wang
Lei Wang
ZLZhifeng Lei
Zhifeng Lei
Heavy ion-induced electrical degradations and mechanisms of high-electron-mobility transistors (HEMTs) were investigated in this article. AlGaN/GaN HEMTs were irradiated by 800-MeV Bi ions with total fluence of 5.23×10 10 ions/cm 2 . The results show that the saturation current decreased by 13.1%, the threshold voltage negatively shifted by 0.21 V, the peak transconductance decreased by 26.6%, the reverse gate-leakage current increased much more than 16 times, and forward gate-leakage current increased more than three times. Furthermore, all electrical performances experienced partial recovery after room temperature annealing (RTA) and 175 °C thermal annealing except gate-leakage current. To further explore the mechanism of gate-leakage degradation, AlGaN/GaN heterojunction wafers were exposed to 1400-MeV Ta ions with fluence of 6.86×107 ions/cm 2 , and characterized by conductive atomic force microscope (CAFM) before and after the irradiation. The results show that the leakage current significantly increased in AlGaN material areas after the irradiation. Comparing the increase in gate leakage of the AlGaN/GaN heterojunction and AlGaN/GaN HEMT induced by heavy ions irradiation, it can be seen that the gate-leakage current of AlGaN/GaN HEMT after heavy irradiation almost entirely was caused by latent tracks. The mechanism for the irreversible increase in gate leakage after heavy ions irradiation could be attributed to the latent tracks along the ion trajectories through the heterojunction.

27 October 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WSWeiheng Shao
Weiheng Shao
XTXinxin Tian
Xinxin Tian
RCRongquan Chen
Rongquan Chen
XHXiao He
Xiao He
WFwenxiao FANG
wenxiao FANG
YSYunlei Shi
Yunlei Shi
In this paper, systematic characterization of the dual probe, which is designed for the near field simultaneous measurement of both electric and magnetic field, is investigated rgb0,0,0with a microstrip line as the device under test (DUT). The characterization includes frequency response, transmission performance, symmetry, reflection, the intrusion of probe to the DUT, isolation of electric and magnetic field responses, field profile and spatial resolution, and differential electric field suppression. The dual probes with different design are adopted to demonstrate the systematic characterization.

13 March 2019 in IEEE Access
Verified
Journal Article
Open access
LWLei Wang
Lei Wang
WFWen-Xiao Fang
Wen-Xiao Fang
YEYun-Fei En
Yun-Fei En
YHYun Huang
Yun Huang
WSWei-Heng Shao
Wei-Heng Shao
BYBin Yao
Bin Yao

11 April 2019 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
CLChengyang Luo
Chengyang Luo
WFwenxiao FANG
wenxiao FANG
YSYang Shen
Yang Shen
HQHaimi Qiu
Haimi Qiu
WSWeiheng Shao
Weiheng Shao
YEYunfei En
Yunfei En
With the trend of miniature, high-integrated assembly modules are common in modern industry. The measurement of the flowing current and voltage on a trace is basic for diagnosis and monitoring of these modules. The traditional contact detection method is not practical especially in conditions of high power and small space. In this paper, we demonstrate a novel method for collocated and simultaneous measurements of radio frequency current and voltage on a trace in a noncontact and movable manner. The measurements are achieved by using a compact probe with both voltage and current detectors, as well as an algorithm based on the transfer functions quantifying the capacitive and inductive couplings between the detectors and the tested trace. The proposed method is verified and applied for continuous power measurements, collocated and simultaneous measurements of transient voltage and current pulses and the dynamic voltage and current of a switching device.