Xinxin Tian

Xinxin Tian

Auto-generated profile, based on publicly available information

Xinxin Tian

School of Physics and Optoelectronic Engineering, Guangdong University of Technology, Guangzhou, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
GLGuangwei Li
Guangwei Li
WSWeiheng Shao
Weiheng Shao
RCRongquan Chen
Rongquan Chen
XTXinxin Tian
Xinxin Tian
QHQuan Huang
Quan Huang
YCYiqiang Chen
Yiqiang Chen
In this paper, an ultrawideband differential magnetic near field probe with high electric field suppression is developed. A pair of differential loops, via fence and shielding vias below the loops are designed to reduce the electric field coupling. It is shown that the electric field suppression of the proposed magnetic-field probe is higher than 30 dB up to 12.9 GHz and 21 dB up to 14 GHz. Due to the differential loops and shielding vias, the proposed magnetic-field probe shows better electric field suppression and sensitivity performance, while maintaining similar spatial resolution. Two other probes with single loop for sensing and without shielding vias are prepared for comparison.

15 July 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WSWeiheng Shao
Weiheng Shao
WFwenxiao FANG
wenxiao FANG
RCRongquan Chen
Rongquan Chen
LWLei Wang
Lei Wang
XTXinxin Tian
Xinxin Tian
CHChunyong Han
Chunyong Han
To measure the magnetic near field with high common mode noise rejection, a probe with the differential and symmetrical structure forming a detection loop is developed. Such measurement is performed by using a two-port vector network analyzer (VNA), and validated by using a microstrip line as device under test (DUT). In comparison to the measurement with traditional single-output magnetic near field probe, the electric field suppression of the proposed measurement can be improved by at least 10 dB in the frequency range of 3∼11 GHz, while the other characteristics basically remain unchanged.

15 March 2023 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
XTXinxin Tian
Xinxin Tian
SXShan Xue
Shan Xue
WSWeiheng Shao
Weiheng Shao
DWDuo-Long Wu
Duo-Long Wu
Microstrip line is commonly used as a calibrator for probe calibration. However, some issues need to be addressed for high frequency application, such as ripple and attenuation caused by the embedded part of the calibrator. In this paper, an ultra-wideband de-embedding calibration method (DCM) for magnetic field probe is proposed. Two symmetric non-soldering grounded coplanar waveguide (GCPW) calibrators, including Through and Line standards, are used to solve the de-embedded S -parameter matrix of a 3-port calibration system. Compared with the traditional calibration method (TCM), the proposed method can reduce the influence of the reflection and attenuation caused by the embedded part and preserve the intrinsic properties of the probe itself. By using the DCM with a symmetric and good matched GCPW calibrator, the ripples of the DCM decreases by 6.57 dB, which is 82 % of the TCM with a microstrip line, and the attenuation has been compensated by about 0.7 dB at 10 GHz. In addition, a new characterization method of common mode suppression ratio for H-field probe is also presented, and it is applicable to conducted emissions measurement in which a probe can detect signals without 90° rotation.

27 October 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WSWeiheng Shao
Weiheng Shao
XTXinxin Tian
Xinxin Tian
RCRongquan Chen
Rongquan Chen
XHXiao He
Xiao He
WFwenxiao FANG
wenxiao FANG
YSYunlei Shi
Yunlei Shi
In this paper, systematic characterization of the dual probe, which is designed for the near field simultaneous measurement of both electric and magnetic field, is investigated rgb0,0,0with a microstrip line as the device under test (DUT). The characterization includes frequency response, transmission performance, symmetry, reflection, the intrusion of probe to the DUT, isolation of electric and magnetic field responses, field profile and spatial resolution, and differential electric field suppression. The dual probes with different design are adopted to demonstrate the systematic characterization.

22 March 2023 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
JLJianfeng Li
Jianfeng Li
TXTao Xu
Tao Xu
DWDuo-Long Wu
Duo-Long Wu
ZHZhen-Xin Hu
Zhen-Xin Hu
GZGary Zhang
Gary Zhang
LYLiang Hua Ye
Liang Hua Ye
With wide impedance bandwidth (IBW), wide axial-ratio bandwidth (ARBW), stable AR beamwidth, and stable half-power beamwidth (HPBW), a dual-circularly-polarized (DCP) crossed-dipole antenna is proposed. Each dipole consisting of two patches is fed by a pair of parallel transmission line, leading to a wide IBW. To enhance the ARBW and AR beamwidth, a quadrature wideband coupler is used, and the overlapping bandwidth of IBW and ARBW is up to 100%. The quadrature coupler is integrated with two pairs of parallel transmission line, and are printed on two substrates, which are squeezed into the space between the radiators and reflector, resulting into a compact antenna structure. With a total height of 0.016 λ L , a prototype is fabricated and measured, showing 1.5-VSWR IBW of larger than 104% for both Left-handed CP (LHCP) and Right-handed CP (RHCP), 3-dB ARBW of up to 100% both for LHCP and RHCP, and port-to-port (polarization) isolation of lager than 30 dB in 1.70 - 2.82 GHz, so the effective bandwidth (EBW) is about 50% (1.70 - 2.82 GHz). 3-dB AR beamwidth of 76° ± 5°, stable DCP characteristics with average gain of 7.2 dBi and HPBWs of 67° ± 4° are achieved.

28 October 2022 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
WSWeiheng Shao
Weiheng Shao
HLHui Li
Hui Li
XTXinxin Tian
Xinxin Tian
BHBo Hou
Bo Hou
SXShan Xue
Shan Xue
CZChangjian Zhou
Changjian Zhou
Calibration for asymmetry of the simultaneously electromagnetic near-field probing system is a good way of improving the performance of a two-port probe. The previous rotating asymmetric calibration method (RACM) based on microstrip line measurements at two directions of 0 $^\circ$ and 90 $^\circ$ is limited to 12 GHz. In this article, a nonrotating asymmetric calibration method (NRACM) is proposed for ultrawideband calibration of a simultaneously near-field probing system. A four-port vector network analyzer and a highly symmetric grounded coplanar waveguide (GCPW) calibrator are used to solve the calibration matrix in the proposed method. It only needs to place the probe at one direction of 0 $^\circ$ instead of measurements at two directions and uses the time-domain reflectometry (TDR) for localization of the probe loop. These simplified measurement steps in the proposed method reduce the impact of positioning error. The non-TEM effect is automatically avoided because of no 90 $^\circ$ measurement. A highly symmetric ultrawideband GCPW calibrator without soldering is adopted to excite standard electromagnetic fields for calibration. The measurement results of standing waves demonstrate that the proposed method is suitable for asymmetric calibration at a frequency as high as 20 GHz.