ANTONIO GALGARO

Prof. Dr. ANTONIO GALGARO

Department of Geosciences, University of Padua, 35131 Padua, Italy
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Géotechnique
Verified
Journal Article
Closed access
Giorgia Dalla SantaGiorgia Dalla Santa
Giorgia Dalla Santa
Simonetta ColaSimonetta Cola
Simonetta Cola
MSMichele Secco
Michele Secco
FTF. Tateo
F. Tateo
RSR. Sassi
R. Sassi
ANTONIO GALGAROANTONIO GALGARO
ANTONIO GALGARO
The freeze–thaw cycles artificially induced in the ground by ground source heat pump systems working at sub-zero temperatures, or during underwater soil excavation, could cause unwanted permanent effects on the hydro-mechanical behaviour of the surrounding deposits. Cohesive deposits present a specific sensitivity to these processes connected to phase changes occurring in the interstitial fluid. The experiments conducted on normally consolidated cohesive soils point out that freeze–thaw cycles can cause a hysteretic increase in vertical permeability of about one order of magnitude, despite a significant concurrent reduction in void ratio. Although the induced freeze–thaw processes are quite constrained close to the borehole heat exchanger, the vertical permeability increase may lead to the risk of connecting aquifers previously separated by cohesive layers, with an overall effect that increases according to the number of probes in the array. Permeability variation appears to be due to the irreversible alteration of the microstructure provoked during the development of freeze–thaw processes. In this paper, the changes of the macroscale hydraulic conductivity are related to changes in the porous microstructural variations, detected in a wide dimensional range by means of a combination of X-ray computed micro tomography, scanning electron microscopy and mercury intrusion porosimetry.

13 June 2017 in Energies
Verified
Journal Article
Open access
PDF file
Angelo ZarrellaAngelo Zarrella
Angelo Zarrella
GEGiuseppe Emmi
Giuseppe Emmi
SGSamantha Graci
Samantha Graci
MCMichele De Carli
Michele De Carli
MCMatteo Cultrera
Matteo Cultrera
Adriana BernardiAdriana Bernardi
Adriana Bernardi
The design phase of ground source heat pump systems is an extremely important one as many of the decisions made at that time can affect the system’s energy performance as well as installation and operating costs. The current study examined the interpretation of thermal response testing measurements used to evaluate the equivalent ground thermal conductivity and thus to design the system. All the measurements were taken at the same geological site located in Molinella, Bologna (Italy) where a variety of borehole heat exchangers (BHEs) had been installed and investigated within the project Cheap-GSHPs (Cheap and efficient application of reliable Ground Source Heat exchangers and Pumps) of the European Union’s Horizon 2020 research and innovation program. The measurements were initially analyzed in accordance with the common interpretation based on the first-order approximation of the solution for the infinite line source model and then by utilizing the complete solutions of both the infinite line and cylinder source models. An inverse numerical approach based on a detailed model that considers the current geometry of the BHE and the axial heat transfer as well as the effect of weather on the ground surface was also used. Study findings revealed that the best result was generally obtained using the inverse numerical interpretation.


20 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
GCGIANLUCA CADELANO
GIANLUCA CADELANO
FCFrancesco Cicolin
Francesco Cicolin
GEGiuseppe Emmi
Giuseppe Emmi
GMGiulia Mezzasalma
Giulia Mezzasalma
DPDavide Poletto
Davide Poletto
Adriana BernardiAdriana Bernardi
Adriana Bernardi
Museums are major energy consumers amongst buildings, especially if they are housed in historical constructions. Museums usually present high energy demand for the air-conditioning due to their architectonical and structural characteristics, such as the presence of large exhibition rooms and open spaces. At the same time, temperature and humidity have to be strictly controlled in order to assure proper microclimate conditions for the conservation of the housed collections and adequate thermal comfort for visitors and personnel. Moreover, despite being subjected to architectural protection that limits most structural refurbishment interventions, these buildings must be adequate from an energy point of view to allow their reuse or continuity of use according to current quality standards, while retaining their heritage significance. In this awkward context, ground source heat pump working with high temperature terminals is proposed as a viable refurbishment solution. The use of shallow geothermal systems can improve the energy efficiency of the heating ventilation air-conditioning systems and, at the same time, increases the renewable energy source exploitation without affecting the indoor environmental conditions. However, after the interventions, the expected benefits and the sought-after limitation of energy consumption/cost may not occur for different reasons. In fact, even if the installed solution is working perfectly and properly designed, every effort will be in vain if adequate attention is not paid to the management of the plants during the operational phase. This document is meant to evaluate and compare the magnitude that invasive (i.e., technical interventions) and not invasive (i.e., energy management policies) actions respectively and their combined interaction, have on a museum. Through energy simulations it has been possible to quantify the effects that different interventions and energy management strategies had on an existing museum housed in an historical building, from energy consumption, energy costs and CO2 emission standpoints.

1 January 2017 in Geothermics
Verified
Journal Article
Closed access
GEGiuseppe Emmi
Giuseppe Emmi
Angelo ZarrellaAngelo Zarrella
Angelo Zarrella
MCMichele De Carli
Michele De Carli
MDMirco Donà
Mirco Donà
ANTONIO GALGAROANTONIO GALGARO
ANTONIO GALGARO

17 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
DQDavide Quaggiotto
Davide Quaggiotto
Angelo ZarrellaAngelo Zarrella
Angelo Zarrella
GEGiuseppe Emmi
Giuseppe Emmi
MCMichele De Carli
Michele De Carli
LPLuc Pockele
Luc Pockele
Adriana BernardiAdriana Bernardi
Adriana Bernardi
In this study, the thermal behavior of the coaxial and double U borehole heat exchangers was investigated using numerical simulations in both the long- and short-term. As a reference for borehole heat exchanger specifications, the existing coaxial and double U probes of a geothermal heat pump installed within the Horizon 2020 research project named “Cheap GSHPs” were considered. Nine years of simulations revealed that when borehole heat exchangers are subjected to a balanced thermal load, and intermittent operating modes of the ground source heat pump system are set, the coaxial pipes’ configuration provides better thermal performance due to the higher thermal capacitance of the heat-carrier fluid and the lower borehole thermal resistance. The analysis was conducted considering two different types of ground with different thermal conductivity values. As result, the more conductive ground type highlights the higher yield of the coaxial probe.