The aim of this article is to predict the compressive strength of environmentally friendly concrete modified with eggshell powder. For this purpose, an optimized artificial neural network, combined with a novel metaheuristic shuffled frog leaping optimization algorithm, was employed and compared with a well-known genetic algorithm and multiple linear regression. The presented results confirm that the highest compressive strength (46 MPa on average) can be achieved for mix designs containing 7 to 9% of eggshell powder. This means that the strength increased by 55% when compared to conventional Portland cement-based concrete. The comparative results also show that the proposed artificial neural network, combined with the novel metaheuristic shuffled frog leaping optimization algorithm, offers satisfactory results of compressive strength predictions for concrete modified using eggshell powder concrete. Moreover, it has a higher accuracy than the genetic algorithm and the multiple linear regression. This finding makes the present method useful for construction practice because it enables a concrete mix with a specific compressive strength to be developed based on industrial waste that is locally available.
The sloshing phenomenon is an important field of fluid dynamics in liquid storage tanks under earthquake excitation. When the sloshing frequency gets close to the liquid tank’s natural frequency, the resulting resonance could lead to instability and even damage to structures, followed by catastrophic economic losses and environmental damages. As passive control devices, baffles are a place for liquid energy dissipation. This study uses annular and horizontal baffles to evaluate the baffles’ relative effectiveness on the elevated storage tanks’ dynamic response. The analysis results are compared with those of elevated storage tanks with no baffles. The flexible and rigid storage tank analysis is examined here, where half of the tank height is filled with liquid. The structural interaction between the liquid, the (horizontal and annular) baffle, and the elevated storage tank affected by seismic action are investigated using Abaqus software. The results confirm that using the baffles, the maximum base shear force in flexible and rigid elevated storage tanks decreases as much as 26.43% and 31.90%, respectively, and the maximum hydrodynamic pressure reduction in the tank is 50.1%.
This study deploys a hybrid Grey Wolf Optimizer Neural Network Model for predicting the crack width in reinforced concrete slabs strengthened with carbon fiber-reinforced polymers (CFRP). Reinforced concrete (RC) one-way slabs (1800 × 400 × 120 mm in size) were strengthened with CFRP with various lengths (1800, 1100, and 700 mm) and subjected to four-point bending. The experimental results were compared to corresponding values for conventional RC slabs. The observed crack width results were recorded, and subsequently examined against the expression recommended by Eurocode 2. To estimate the crack width of CFRP-reinforced slabs, ANN combined with the Grey Wolf Optimizer algorithm was employed whereby the applied load, CFRP width/length, X/Y crack positions, and stress in steel reinforcement and concrete were defined as the input parameters. Experimental results showed that the larger the length and width of the carbon fiber, the smaller the maximum crack width in the tensile area of the slab at the final load step. On average, the crack width in slabs retrofitted with CFRP laminates increased by around 80% compared to a slab without CFRP. The results confirm that the equation provided by Eurocode 2 provides an unconservative estimation of crack widths for RC slabs strengthened with CFRP laminates. On the other hand, the results also confirm that the proposed informational model could be used as a reliable tool for estimating the crack width in RC slabs. The findings provide valuable insight into the design approaches for RC slabs and rehabilitation strategies for existing deficient RC slabs using CFRP.
The present study investigates the blast effect on hoop stresses and displacements created on the wall of over-ground cylindrical reinforced concrete water storage tanks and the effect of blast waves, fluid surface motion, and the surface tension of water due to water-structure interaction using ABAQUS software. Three tanks with heights of 4, 6, and 8 m and a fixed radius of 3 m were used for simulation, each of which was filled with 0, 25, 50, 75, and 100% water from the depth of the tank. The results revealed that the above parameters affect the tank structure’s dynamic response so that the surface tension of water is higher in tanks with 50% water filling. Also, increasing the water filling percentage, the hardness of the tank increased and decreased the tank wall displacement by 31.25% for a filled tank compared to an empty tank. Water filling also reduced the sensitivity of tanks to instability. The results showed that the tank wall’s hoop stresses were affected by blast waves from the outside and water tension from the inside, so that the water tension in the tank caused an approximate 20 MPa increase in the hoop stresses on the wall.
1 October 2019 in Journal of Central South University
In this experimental study, the mechanical strength properties of concrete using 5, 8 and 12% of organic waste ash (OWA) instead of cement are investigated. The results showed that the 28 days compressive and tensile strength and slump of the concrete made by OWA in compared with ordinary concrete were 0.99, 0.99, and 0.8, respectively, for 5% OWA instead of cement, 0.96, 0.9, and 0.69, respectively, for 8% OWA instead of cement, and 0.9, 0.9, and 0.09, respectively, for 12% OWA instead of cement.