Alojz Poredos

Prof. Dr. Alojz Poredos

Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana 1000, Slovenia

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2007 in Energy Policy
Verified
Journal Article
Closed access
Primož PotočnikPrimož Potočnik
Primož Potočnik
MTMarko Thaler
Marko Thaler
EGEdvard Govekar
Edvard Govekar
IGIgor Grabec
Igor Grabec
APAlojz Poredos
Alojz Poredos

4 March 2013 in Energies
Verified
Journal Article
Open access
PDF file
ALAndrej Ljubenko
Andrej Ljubenko
APAlojz Poredos
Alojz Poredos
Tatiana MorosukTatiana Morosuk
Tatiana Morosuk
George TsatsaronisGeorge Tsatsaronis
George Tsatsaronis
Lowering the exergy content of heat required for heating purposes decreases the primary energy consumption. District heating systems are often an important link between facilities that generate heat with low exergy content and consumers. Exergetic efficiency of heat distribution is an important performance criterion in heat supply to consumers. It can serve as a criterion for optimization, towards a more sustainable distribution-network design and operation. This paper presents a methodology for an exergy-based distribution-network analysis in a district heating system. Criteria for performance evaluations are defined. They can be used to evaluate heat supply to different points in the network, or individual system components. A case study is performed on an existing district heating system. Energetic and exergetic efficiencies of supply lines are analyzed. Exergy destructions and exergy losses are studied. Large differences in efficiency of heat supply to different points in the network are discovered. Over-dimensioned parameters of the distribution network are investigated.

30 December 2020 in Entropy
Verified
Journal Article
Open access
PDF file
PPPrimož Poredoš
Primož Poredoš
BVBoris Vidrih
Boris Vidrih
APAlojz Poredos
Alojz Poredos
The main research objective of this paper was to compare exergy performance of three different heat pump (HP)-based systems and one natural gas (NG)-based system for the production of heating and cooling energy in a single-house dwelling. The study considered systems based on: 1. A NG and auxiliary cooling unit; 2. Solely HP, 3. HP with additional seasonal heat storage (SHS) and a solar thermal collector (STC); 4. HP with SHS, a STC and a grey water (GW) recovery unit. The assessment of exergy efficiencies for each case was based on the transient systems simulation program TRNSYS, which was used for the simulation of energy use for space heating and cooling of the building, sanitary hot water production, and the thermal response of the seasonal heat storage and solar thermal system. The results show that an enormous waste of exergy is observed by the system based on an NG boiler (with annual overall exergy efficiency of 0.11) in comparison to the most efficient systems, based on HP water–water with a seasonal heat storage and solar thermal collector with the efficiency of 0.47. The same system with an added GW unit exhibits lower water temperatures, resulting in the exergy efficiency of 0.43. The other three systems, based on air–, water–, and ground–water HPs, show significantly lower annual source water temperatures (10.9, 11.0, 11.0, respectively) compared to systems with SHS and SHS + GW, with temperatures of 28.8 and 19.3 K, respectively.

15 November 2011 in Strojniški vestnik - Journal of Mechanical Engineering
Verified
Journal Article
Closed access
ALAndrej Ljubenko
Andrej Ljubenko
APAlojz Poredos
Alojz Poredos
MZMiran Zager
Miran Zager
In this paper the attention is on the heat losses of a main, aboveground supply, hot-water pipeline, whose length is 5430 m. It is situated between the Šoštanj Thermal Power Plant (TEŠ) and the Central Energy Station (CES) Velenje as part of the district heating system in the Šaleška Valley. It was renovated because major heat losses were identified. A numerical analysis and a comparison between the temperature fields of the pipeu27s insulation before and after the renovation was performed to discover the main causes for the high heat losses before renovation. An integral measuring method for determining the heat losses was adapted and used to determine the pipelineu27s heat losses after the renovation. Taking into consideration the real operating parameters, the annual energy savings and the consequent operational cost reduction, due to the lower heat losses, resulting from the pipeline renovations, are presented. The calculation is made with measured heat-loss coefficients and is therefore based on the real state of the pipeline. The aim is to show the necessity to investigate the heat losses of a hot-water pipeline whose design or state of insulation is questionable

10 April 2019 in Entropy
Verified
Journal Article
Open access
PDF file
PPPrimož Poredoš
Primož Poredoš
Andrej KitanovskiAndrej Kitanovski
Andrej Kitanovski
APAlojz Poredos
Alojz Poredos
This paper presents an exergy-efficiency analysis of low-temperature district heating systems (DHSs) with different sanitary hot-water (SHW) boosters. The required temperature of the sanitary hot water (SHW) was set to 50 °C. The main objective of this study was to compare the exergy efficiencies of a DHS without a booster to DHSs with three different types of boosters, i.e., electric-, gas-boiler- and heat-pump-based, during the winter and summer seasons. To achieve this, we developed a generalized model for the calculation of the exergy efficiency of a DHS with or without the booster. The results show that during the winter season, for a very low relative share of SHW production, the DHS without the booster exhibits favorable exergy efficiencies compared to the DHSs with boosters. By increasing this share, an intersection point above 45 °C for the supply temperatures, at which the higher exergy efficiency of a DHS with a booster prevails, can be identified. In the summer season the results show that a DHS without a booster at a supply temperature above 70 °C achieves lower exergy efficiencies compared to DHSs with boosters at supply temperatures above 40 °C. The results also show that ultra-low supply and return temperatures should be avoided for the DHSs with boosters, due to higher rates of entropy generation.

23 July 2018 in Journal of Energy Resources Technology
Verified
Journal Article
Closed access
PDF file
PPPrimož Poredoš
Primož Poredoš
BVBoris Vidrih
Boris Vidrih
Andrej KitanovskiAndrej Kitanovski
Andrej Kitanovski
APAlojz Poredos
Alojz Poredos