Primož Poredoš

Primož Poredoš


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2015 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
PPPrimož Poredoš
Primož Poredoš
DČDušan Čelan
Dušan Čelan
JMJanez Možina
Janez Možina
Matija JezersekMatija Jezersek
Matija Jezersek
The main objective of the present method was to automatically obtain a spatial curve of the thoracic and lumbar spine based on a 3D shape measurement of a human torso with developed scoliosis. Manual determination of the spine curve, which was based on palpation of the thoracic and lumbar spinous processes, was found to be an appropriate way to validate the method. Therefore a new, noninvasive, optical 3D method for human torso evaluation in medical practice is introduced. Twenty-four patients with confirmed clinical diagnosis of scoliosis were scanned using a specially developed 3D laser profilometer. The measuring principle of the system is based on laser triangulation with one-laser-plane illumination. The measurement took approximately 10 seconds at 700 mm of the longitudinal translation along the back. The single point measurement accuracy was 0.1 mm. Computer analysis of the measured surface returned two 3D curves. The first curve was determined by manual marking (manual curve), and the second was determined by detecting surface curvature extremes (automatic curve). The manual and automatic curve comparison was given as the root mean square deviation (RMSD) for each patient. The intra-operator study involved assessing 20 successive measurements of the same person, and the inter-operator study involved assessing measurements from 8 operators. The results obtained for the 24 patients showed that the typical RMSD between the manual and automatic curve was 5.0 mm in the frontal plane and 1.0 mm in the sagittal plane, which is a good result compared with palpatory accuracy (9.8 mm). The intra-operator repeatability of the presented method in the frontal and sagittal planes was 0.45 mm and 0.06 mm, respectively. The inter-operator repeatability assessment shows that that the presented method is invariant to the operator of the computer program with the presented method. The main novelty of the presented paper is the development of a new, non-contact method that provides a quick, precise and non-invasive way to determine the spatial spine curve for patients with developed scoliosis and the validation of the presented method using the palpation of the spinous processes, where no harmful ionizing radiation is present.

19 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
PPPrimož Poredoš
Primož Poredoš
NPNada Petelin
Nada Petelin
TŽTilen Žel
Tilen Žel
BVBoris Vidrih
Boris Vidrih
PGPero Gatarić
Pero Gatarić
Andrej KitanovskiAndrej Kitanovski
Andrej Kitanovski
The condensation of humid air is a crucial step in air conditioning and process engineering. However, the models that describe the condensation of vapour in the presence of a non-condensable gas require time-consuming numerical calculations that go beyond the Nusselt film theory. Only a small number of publications exist, where simple and computationally effective correlations for the condensation of water vapour in the presence of air are presented for specially designed condenser heat exchangers. Therefore, the objective of this paper is to extend the existing semi-empirical correlations for different geometries and process parameters. For the purpose of the study, an experimental setup with two different condenser heat exchangers based on vertical plates (height 74 mm) and horizontal tubes (3 tubes, diameter 40 mm and 7 tubes, diameter 15 mm) was built. Additionally, based on existing correlations, we developed two semi-empirical models that predict the condensation mass flux for the proposed geometries. Here, we report that the agreement between the experimental and theoretical values predicted by the new, semi-empirical correlations is excellent, with an average uncertainty of less than ±6%. Their usability was demonstrated by a possibly significant performance improvement of the condenser inside a condensation-type tumble dryer.

30 December 2020 in Entropy
Verified
Journal Article
Open access
PDF file
PPPrimož Poredoš
Primož Poredoš
BVBoris Vidrih
Boris Vidrih
APAlojz Poredos
Alojz Poredos
The main research objective of this paper was to compare exergy performance of three different heat pump (HP)-based systems and one natural gas (NG)-based system for the production of heating and cooling energy in a single-house dwelling. The study considered systems based on: 1. A NG and auxiliary cooling unit; 2. Solely HP, 3. HP with additional seasonal heat storage (SHS) and a solar thermal collector (STC); 4. HP with SHS, a STC and a grey water (GW) recovery unit. The assessment of exergy efficiencies for each case was based on the transient systems simulation program TRNSYS, which was used for the simulation of energy use for space heating and cooling of the building, sanitary hot water production, and the thermal response of the seasonal heat storage and solar thermal system. The results show that an enormous waste of exergy is observed by the system based on an NG boiler (with annual overall exergy efficiency of 0.11) in comparison to the most efficient systems, based on HP water–water with a seasonal heat storage and solar thermal collector with the efficiency of 0.47. The same system with an added GW unit exhibits lower water temperatures, resulting in the exergy efficiency of 0.43. The other three systems, based on air–, water–, and ground–water HPs, show significantly lower annual source water temperatures (10.9, 11.0, 11.0, respectively) compared to systems with SHS and SHS + GW, with temperatures of 28.8 and 19.3 K, respectively.

10 April 2019 in Entropy
Verified
Journal Article
Open access
PDF file
PPPrimož Poredoš
Primož Poredoš
Andrej KitanovskiAndrej Kitanovski
Andrej Kitanovski
APAlojz Poredos
Alojz Poredos
This paper presents an exergy-efficiency analysis of low-temperature district heating systems (DHSs) with different sanitary hot-water (SHW) boosters. The required temperature of the sanitary hot water (SHW) was set to 50 °C. The main objective of this study was to compare the exergy efficiencies of a DHS without a booster to DHSs with three different types of boosters, i.e., electric-, gas-boiler- and heat-pump-based, during the winter and summer seasons. To achieve this, we developed a generalized model for the calculation of the exergy efficiency of a DHS with or without the booster. The results show that during the winter season, for a very low relative share of SHW production, the DHS without the booster exhibits favorable exergy efficiencies compared to the DHSs with boosters. By increasing this share, an intersection point above 45 °C for the supply temperatures, at which the higher exergy efficiency of a DHS with a booster prevails, can be identified. In the summer season the results show that a DHS without a booster at a supply temperature above 70 °C achieves lower exergy efficiencies compared to DHSs with boosters at supply temperatures above 40 °C. The results also show that ultra-low supply and return temperatures should be avoided for the DHSs with boosters, due to higher rates of entropy generation.

1 September 2015 in Scoliosis
Verified
Journal Article
Open access
PDF file
DČDušan Čelan
Dušan Čelan
BPBreda Jesenšek Papež
Breda Jesenšek Papež
PPPrimož Poredoš
Primož Poredoš
JMJanez Možina
Janez Možina
The main purpose of this research was to develop a new method for differentiating between scoliotic and healthy subjects by analysing the curvatures of their spines in the cranio-caudal view. The study included 247 subjects with physiological curvatures of the spine and 28 subjects with clinically confirmed scoliosis. The curvature of the spine was determined by a computer analysis of the surface of the back, measured with a non-invasive, 3D, laser-triangulation system. The determined spinal curve was represented in the transversal plane, which is perpendicular to the line segment that was defined by the initial point and the end point of the spinal curve. This was achieved using a rotation matrix. The distances between the extreme points in the antero-posterior (AP) and left-right (LR) views were calculated in relation to the length of the spine as well as the quotient of these two values LR/AP. All the measured parameters were compared between the scoliotic and control groups using the Student’s t-Test in case of normal data and Kruskal-Wallis test in case of non-normal data. Besides, a comprehensive diagram representing the distances between the extreme points in the AP and LR views was introduced, which clearly demonstrated the direction and the size of the thoracic and lumbar spinal curvatures for each individual subject. While the distances between the extreme points of the spine in the AP view were found to differ only slightly between the groups (p = 0.1), the distances between the LR extreme points were found to be significantly greater in the scoliosis group, compared to the control group (p < 0.001). The quotient LR/AP was statistically significantly different in both groups (p < 0.001). The main innovation of the presented method is the ability to differentiate a scoliotic subject from a healthy subject by assessing the curvature of the spine in the cranio-caudal view. Therefore, the proposed method could be useful for human posture diagnostics as well as to provide a long-term monitoring of scoliotic spine curvatures in preventive and curative clinical practice at all levels of health care.

23 July 2018 in Journal of Energy Resources Technology
Verified
Journal Article
Closed access
PDF file
PPPrimož Poredoš
Primož Poredoš
BVBoris Vidrih
Boris Vidrih
Andrej KitanovskiAndrej Kitanovski
Andrej Kitanovski
APAlojz Poredos
Alojz Poredos