In the frame of technology development, fused deposition modeling is adapted in this study to elaborate composite material from 20% short carbon fiber reinforced polyether ether ketone (CF/PEEK) filament. This printing technology has attached widespread intention as it provides a rapid prototyping parts with high performances in diverse fields. For this purpose, a set of experimental tensile and bending tests are carried out to focus on the effect of printing orientation on the mechanical properties of the designed samples. Three raster angles are considered in this investigation: 0°, ±45°, and 90°. The obtained results indicate that the printing orientation of 0°, which is parallel to the tensile loading path and perpendicular to the flexural one exhibits higher mechanical strength compared to the other orientations. Evolution of Young modulus, total elongation at failure, yield and ultimate strengths as well as deflection are also discussed. Experimental work is supported by numerical simulation and a good agreement is revealed. Microstructural analysis is performed in order to argue the observed mechanical behavior. Through the fractured section morphology, the effect of tensile loading on CF/PEEK microstructure, at various printing orientation is emphasized.
In this research work, design optimization and static analysis of a 3D printed based carbon PEEK (poly ether ether ketone, reinforced with carbon) polymer composite mono leaf spring was done using finite element analysis. Comparative study of leaf springs of a Dodge SUV car has been made by using 3D printed carbon PEEK. The main objective of this work is to optimize the design and material parameters, such as fiber diameter, fiber length, percentage volume of fibers and orientation angle of fibers in 3D printed based material with a mono polymer composite leaf spring. The effects of these parameters were studied to evaluate the deflection, bending stress, spring rate, stiffness and von Mises stress under different loading conditions. Furthermore investigation has been done to reduce the weight of leaf springs and claimed the 3D printed based leaf springs have better load carrying capacity. Thus an attempt has been made in this regard and we selected the 3D printed carbon PEEK in developing product design and material selection for minimum deflection and bending stress by means of response surface optimization methodology for an efficient leaf spring suspension system. The 3D printed carbon fiber polymer composite has three different percentage volume fractions such as 30%, 50%, and 60%. The selected carbon PEEK has 0°, 45°, and 90° fiber orientations. Finite element based analysis has been performed on 3D printed carbon PEEK material to conclude the optimized design parameters and best possible combination of factors affecting the leaf spring performance.
Intravenous delivery is the fastest conventional method of delivering drugs to their targets in seconds, whereas intramuscular and subcutaneous injections provide a slower continuous delivery of drugs. In recent years, nanoparticle-based drug-delivery systems have gained considerable attention. During the progression of nanoparticles into the blood, the sound waves generated by the particles create acoustic pressure that affects the movement of nanoparticles. To overcome this issue, the impact of sound pressure levels on the development of nanoparticles was studied herein. In addition, a composite nanostructure was developed using different types of nanoscale substances to overcome the effect of sound pressure levels in the drug-delivery process. The results demonstrate the efficacy of the proposed nanostructure based on a group of different nanoparticles. This study suggests five materials, namely, polyimide, acrylic plastic, Aluminum 3003-H18, Magnesium AZ31B, and polysilicon for the design of the proposed structure. The best results were obtained in the case of the movement of these molecules at lower frequencies. The performance of acrylic plastic is better than other materials; the sound pressure levels reached minimum values at frequencies of 1, 10, 20, and 60 nHz. Furthermore, an experimental setup was designed to validate the proposed idea using advanced biomedical imaging technologies. The experimental results demonstrate the possibilities of detecting, tracking, and evaluating the movement behaviors of nanoparticles. The experimental results also demonstrate that the lowest sound pressure levels were observed at lower frequency levels, thus proving the validity of the proposed computational model assumptions. The outcome of this study will pave the way to understand the interaction behaviors of nanoparticles with the surrounding biological environments, including the sound pressure effect, which could lead to the useof such an effect in facilitating directional and tactic movements of the micro- and nano-motors.
In this work, we are interested in examining the strain rate effect on the mechanical behavior of Ni–Ti superelastic wires after hydrogen charging and ageing for 24 h. Specimens underwent 50 cycles of loading-unloading, reaching an imposed deformation of 7.6%. During loading, strain rates from 10−4 s−1 to 10−2 s−1 were achieved. With a strain rate of 10−2 s−1, the specimens were charged by hydrogen for 6 h and aged for one day showed a superelastic behavior marked by an increase in the residual deformation as a function of the number of cycles. In contrast, after a few number of cycles with a strain rate of 10−4 s−1, the Ni-Ti alloy archwire specimens fractured in a brittle manner during the martensite transformation stage. The thermal desorption analysis showed that, for immersed specimens, the desorption peak of hydrogen appeared at 320 °C. However, after annealing the charged specimens by hydrogen at 400 °C for 1 h, an embrittlement took place at the last cycles for the lower strain rates of 10−4 s−1. The present study suggests that the embrittlement can be due to the development of an internal stress in the subsurface of the parent phase during hydrogen charging and due to the creation of cracks and local zones of plasticity after desorption.
Compound nanoparticle drug delivery system plays an important role in the interaction with lymph nodes. There are three primary types of lymphocytes: B cells, T cells, and natural killer cells. When the cells of the immune system turn carcinogenic, they assault body cells. The lymph fluid plays an important role in attacking healthy cells of the body; hence, this paper aimed to design a drug delivery system, which can efficiently direct nanoparticles to target the infected cells, helping in high-speed elimination of such cells. The proposed design depends on the interaction between these molecules, and the intelligent nano-controller has the ability to guide the nanoparticles by anaerobic contact. The proposed design proved that the smaller the nanoparticle size and density, the less dynamic viscosity of the liquid would be, which would reflect its resistance to flow. In addition, it was concluded that hydrogen molecules play a significant role in reducing lymphatic fluid resistance due to their low density.