Gordon Stevenson

Gordon Stevenson

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Obstetrics & Gynecology
Verified
Journal Article
Closed access
SCSally L. Bmbch Collins
Sally L. Bmbch Collins
GSGordon Stevenson
Gordon Stevenson
AAAbdulla Al-Khan
Abdulla Al-Khan
NINicholas Illsley
Nicholas Illsley
LILawrence Mbbs Impey
Lawrence Mbbs Impey
SZStacy Zamudio
Stacy Zamudio
OBJECTIVE: To test an objective ultrasound marker for diagnosing the presence and severity of abnormally invasive placenta. METHODS: Women at risk of abnormally invasive placenta underwent a three-dimensional power Doppler ultrasound scan. The volumes were examined offline by a blinded observer. The largest area of confluent three-dimensional power Doppler signal (Area of Confluence [Acon], cm2) at the uteroplacental interface was measured and compared in women subsequently diagnosed with abnormally invasive placenta and women in a control group who did not have abnormally invasive placenta. Receiver operating characteristic curves were plotted for prediction of abnormally invasive placenta and abnormally invasive placenta requiring cesarean hysterectomy. RESULTS: Ninety-three women were recruited. Results were available for 89. Abnormally invasive placenta was clinically diagnosed in 42 women; 36 required hysterectomy and had abnormally invasive placenta confirmed histopathologically. Median and interquartile range for Acon was greater for abnormally invasive placenta (44.2 [31.4–61.7] cm2) compared with women in the control group (4.5 cm2 [2.9–6.6], P<.001) and even greater in the 36 requiring hysterectomy (46.6 cm2 [37.2–72.6], P<.001). Acon rose with histopathologic diagnosis: focal accreta (32.2 cm2 [17.2–57.3]), accreta (59.6 cm2 [40.1–89.9]), and percreta (46.6 cm2 [37.5–71.5]; P<.001 analysis of variance for linear trend). Receiver operating characteristic analysis for prediction of abnormally invasive placenta revealed that with an Acon of 12.4 cm2 or greater, 100% sensitivity (95% confidence interval [CI] 91.6–100) could be obtained with 92% specificity (95% CI 79.6–97.6); area under the curve is 0.99 (95% CI 0.94–1.0). For prediction of abnormally invasive placenta requiring hysterectomy, 100% sensitivity (95% CI 90.3–100) can be obtained with an Acon of 17.4 cm2 or greater with 87% specificity (95% CI 74.7–94.5; area under the curve 0.98 [0.93–1.0]). CONCLUSION: The marker Acon provides a quantitative means for diagnosing abnormally invasive placenta and assessing severity. If further validated, subjectivity could be eliminated from the diagnosis of abnormally invasive placenta. LEVEL OF EVIDENCE: II

21 November 2011 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Open access
PDF file
SCS. L. Collins
S. L. Collins
JBJ. S. Birks
J. S. Birks
GSGordon Stevenson
Gordon Stevenson
APA. T. Papageorghiou
A. T. Papageorghiou
JNJ. A. Noble
J. A. Noble
LIL. Impey
L. Impey
Objective: To investigate whether the jets of blood from the mouths of the spiral arteries could be measured reliably, as well as their relationship with the uterine artery (UtA) and any differences in small‐for‐gestational‐age (SGA) pregnancies.Methods: Participants underwent serial ultrasound scans, from 11 weeks' gestation. Pulsatility index (PI) and resistance index (RI) of jets into the intervillous space (IVS) and UtA were recorded at every visit. Intra‐ and interobserver variability studies were performed. Customized birth weight centiles were calculated and SGA was defined as < 10th centile. Linear mixed model analysis was used to allow for the longitudinal nature of the data.Results: Sixty‐six women were recruited; 58 remained normotensive and delivered at term. Of these, six women delivered SGA newborns and 52 delivered appropriate‐for‐gestational‐age newborns. All had pulsatile jets until 20 weeks' gestation. The PI and RI of the jets decreased with advancing gestation, following a trend similar to that of the UtAs. There was no correlation between the jets and UtA waveforms when gestational age was controlled for. For intraobserver variability the intraclass correlation coefficient was 0.9. The interobserver study showed no significant difference between the observers. Mixed model analysis demonstrated that PI and RI of jets were different in SGA pregnancies (P < 0.06). This difference was not seen for the UtAs (P = 0.8).Conclusion: This technique enables examination of characteristics of the jets of blood flowing from spiral arteries into the IVS. It is both precise and reproducible, with biologically plausible results. Further work is required to assess differences in pregnancies with adverse outcomes. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.


1 July 2015 in The Journal of Pediatrics
Verified
Journal Article
Closed access
CCCristine Sortica da Costa
Cristine Sortica da Costa
MCMarek Czosnyka
Marek Czosnyka
PSPeter Smielewski
Peter Smielewski
MSMitra Subhabrata
Mitra Subhabrata
GSGordon Stevenson
Gordon Stevenson
TATopun Austin
Topun Austin

25 May 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
PLPadraig Looney
Padraig Looney
YYYi Yin
Yi Yin
SCSally L. Collins
Sally L. Collins
KNKypros H. Nicolaides
Kypros H. Nicolaides
WPWalter Plasencia
Walter Plasencia
GSGordon Stevenson
Gordon Stevenson
Volumetric placental measurement using 3-D ultrasound has proven clinical utility in predicting adverse pregnancy outcomes. However, this metric cannot currently be employed as part of a screening test due to a lack of robust and real-time segmentation tools. We present a multiclass (MC) convolutional neural network (CNN) developed to segment the placenta, amniotic fluid, and fetus. The ground-truth data set consisted of 2093 labeled placental volumes augmented by 300 volumes with placenta, amniotic fluid, and fetus annotated. A two-pathway, hybrid (HB) model using transfer learning, a modified loss function, and exponential average weighting was developed and demonstrated the best performance for placental segmentation (PS), achieving a Dice similarity coefficient (DSC) of 0.84- and 0.38-mm average Hausdorff distances (HDAV). The use of a dual-pathway architecture improved the PS by 0.03 DSC and reduced HDAV by 0.27 mm compared with a naïve MC model. The incorporation of exponential weighting produced a further small improvement in DSC by 0.01 and a reduction of HDAV by 0.44 mm. Per volume inference using the FCNN took 7-8 s. This method should enable clinically relevant morphometric measurements (such as volume and total surface area) to be automatically generated for the placenta, amniotic fluid, and fetus. The ready availability of such metrics makes a population-based screening test for adverse pregnancy outcomes possible.

1 December 2015 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
GSGordon Stevenson
Gordon Stevenson
SCSally L. Collins
Sally L. Collins
JDJane Ding
Jane Ding
LILawrence Impey
Lawrence Impey
JNJ. Alison Noble
J. Alison Noble